video corpo

OMNIZONE?

OMNIZONE?
1 / 80 PagesView full catalog

OMNIZONE?

Product catalog summary
Overview: The document provides comprehensive details on the Omnizone 50BV units by Carrier Corporation, which are versatile, self-contained HVAC systems suitable for various applications, including water-cooled, remote air-cooled, and heat pump configurations. These units are designed for both constant volume (CV) and variable air volume (VAV) applications, offering flexibility, efficiency, and economical operation.
Specifications: The units are available with R-22 or Puron® (R-410A) refrigerant and feature modular construction for easy installation. They are equipped with high-efficiency scroll compressors, suction and discharge Schrader valves, and are designed to fit through standard doorways.
Features and Benefits: Key features include a direct expansion evaporator coil, water-cooled cleanable condensers, and a microprocessor control system. Optional features such as water economizers and hot water heating enhance functionality. Units with Puron refrigerant achieve EERs up to 14.8, while R-22 units reach up to 14.6.
Performance and Efficiency: The units are optimized for heat transfer efficiency with enhanced fin, rifled tube evaporators, ensuring low airside pressure drops and effective moisture removal. Safety features include high-pressure and low-pressure switches, thermostatic expansion valves, and stainless steel or insulated galvanized condensate pans.
Control and Safety: The units come with a factory-mounted VFD, microprocessor control system, and unit control panel with Off/Local/Remote switch and alarm indicator lights. Each compressor has an independent refrigerant circuit with safety protections.
Quality and Reliability: All units are UL and UL, Canada listed, with a standard one-year warranty. They are designed for easy servicing with single-point electrical and piping connections.
Environmental Considerations: Puron refrigerant is environmentally friendly, with low global warming potential and no chlorine content, allowing for efficient refrigerant management.
Applications: Suitable for office environments, these units offer flexible and economical air conditioning solutions, available in single-piece and modular configurations with capacities ranging from 18 to 60 nominal tons.
Key Components and Options: The document details components like waterside economizers, hot water coils, and hot gas reheat systems, along with energy management packages and enhanced condenser materials for improved performance and protection.
Blower Orientation and Dimensions: Blower orientation is adjustable, and detailed dimensions and service clearances are provided for various models.
Performance and Shipping: Performance data is accessible via Carrier's VPACBuilder software, with shipping weights and modular configurations detailed for different unit sizes.
Motor and Drive Combinations: Available motor and drive combinations range from 7.5 to 20 HP, with specific RPM ranges for each type.
Operational Guidelines: Guidelines emphasize the importance of accounting for static pressure losses and adhering to fan performance data without extrapolation.
Electrical Specifications: Electrical data includes details on RLA, LRA, FLA, MCA, and MOCP for compressors and indoor fan motors across different voltages.
Control Wiring Schematics: Notes emphasize compliance with NEC-NFPA #70 and specific wiring instructions for safety and efficiency.
Installation Guidelines: Recommendations include indoor installation, unit isolation, proper ductwork support, and piping configurations for optimal performance.
Operational Limits: Specifies airflow, air temperature, water flow, and water temperature ranges for efficient operation.
Water Quality Recommendations: Guidelines for water quality management are provided to ensure optimal system performance.
Compressor Operation: Units feature four independent compressors for staged control, enhancing efficiency.
Refrigerant Piping: Proper piping is crucial to prevent refrigerant migration and maintain system efficiency.
Additional Notes: Wiring and piping diagrams must comply with local codes, and proper circuit separation is essential.
See more

Catalog excerpts

OMNIZONE?-1

Product Data OMNIZONE™ 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons Omnizone 50BV units offer: • Available with R-22 or Puron® (R-410A) refrigerant • Modular units break down to fit through a standard, 36-in. doorway • Either two or four high-efficiency scroll compressors for efficient part load control, quiet operation and system redundancy • Suction and discharge Schrader valves on manifold gage connections Omnizone 50BV units are self-contained, water-cooled indoor cooling units, remote air-cooled units, or water source heat pumps. 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE UNIT Flexible, efficient and economical 50BVT,U,V,W,X034-064 MODULAR OMNIZONE UNIT Copyright 2008 Carrier Corporation Units are available for either constant volume (CV) or variable air volume (VAV) applications (with the exception of heat pumps) in both modular and single-piece construction. Single-piece units are completely factory wired, piped and charged, ready for installation. Units with Puron refrigerant have EERs up to 14.8, while units with R-22 have EERs up to 14.6. Units include a direct expansion evaporator coil, compressors, and watercooled cleanable condensers (unless remote air-cooled). The VAV units include a single or multiple belt drive evaporator fan(s) with VFD (variable frequency drive) controlled motor and complete microprocessor control system. Optional water economizers and hot water heating may also be added. Form 50BV-4PD

 Open the catalog to page 1
OMNIZONE?-2

Features/Benefits (cont) These vertical package units offer flexible economical air conditioning for today’s office environment. Compressors are mounted on vibration isolators. Each compressor is equipped with a coaxial tube-in-tube condenser for maximum heat transfer efficiency and performance. All condensers are rated at 450 psig operating refrigerant pressures (600 psig for Puron® refrigerant models) and 400 psig water-side pressures. Evaporators are enhanced fin, rifled tube type for maximum performance. Large face areas ensure low airside pressure drops and reduced face velocities to prevent...

 Open the catalog to page 2
OMNIZONE?-3

Model number nomenclature 50BV- OMNIZONE™ Indoor Packaged Cooling Unit Product Type C - (CV) Cool Only, W/C, Single Piece E - (CV) Cool Only, Remote A/C, Single Piece Q - (CV) Heat Pump, W/C, Single Piece J - (VAV) Cool Only, W/C, Single Piece K - (VAV) Cool Only, Remote A/C, Single Piece T - (CV) Cool Only, W/C, Modular U - (CV) Cool Only, Remote A/C, Modular V - (CV) Heat Pump, W/C, Modular W - (VAV) Cool Only, W/C, Modular X - (VAV) Cool Only, Remote A/C, Modular Unit Size - Nominal Tons Economizer and Hot Gas Reheat Options A - Water Economizer with 3-Way Valve Package and B - Water Economizer...

 Open the catalog to page 3
OMNIZONE?-4

ARI* capacity ratings UNIT LEGEND EER — Energy Efficiency Ratio *Air Conditioning and Refrigeration Institute. †R-22 unit rating/R-410A unit rating. NOTE: Units rated in accordance with ARI 340/360-2000 conditions.

 Open the catalog to page 4
OMNIZONE?-5

Physical data — 50BVC,E,J,K,Q units UNIT 50BVC,E,J,K,Q NOMINAL CAPACITY (Tons) SHIPPING WEIGHT (lb) 50BVC,Q…50BVJ 50BVE…50BVK COMPRESSOR Quantity Number of Refrigerant Circuits Oil (ounces) Ckt 1…Ckt 2 REFRIGERANT TYPE Expansion Device Operating Charge (lb) Ckt 1…Ckt 2 CONDENSER (50BVC,Q,J only) Quantity of Manifolded Circuits Nominal Flow Rate (GPM) Water Flow Range (GPM) Max. Water Working Pressure (PSIG) Max. Refrig. Working Pressure (PSIG) Min. Entering Water Temp. (F) Max. Entering Water Temp. (F) Waterside Volume (gal) EVAPORATOR COIL Rows…Fins/in. Total Face Area (sq ft) EVAPORATOR FAN...

 Open the catalog to page 5
OMNIZONE?-6

Physical data — 50BVT,U,V,W,X units UNIT 50BVT,U,V,W,X NOMINAL CAPACITY (Tons) SHIPPING WEIGHT (lb) 50BVT,V…50BVW 50BVU…50BVX COMPRESSOR Quantity Number of Refrigerant Circuits Oil (oz.) Circuit 1…Circuit 2 Circuit 3…Circuit 4 REFRIGERANT TYPE Expansion Device Operating Charge (lb) Circuit 1…Circuit 2 Circuit 3…Circuit 4 CONDENSER (50BVT,V,W only) Quantity of Manifolded Circuits Nominal Flow Rate (GPM) Water Flow Range (GPM) Max. Water Working Pressure (PSIG) Max. Refrig. Working Pressure (PSIG) Min. Entering Water Temp. (F) Max. Entering Water Temp. (F) Waterside Volume (gal) WATERSIDE ECONOMIZER...

 Open the catalog to page 6
OMNIZONE?-7

Factory-installed options Waterside economizer — A condenser water pre-cooling coil located before the direct expansion cooling coils allows the use of the condenser water to provide free cooling. When the condenser water temperature is less than an adjustable set point or more below the return-air temperature, condenser water is directed to the economizer coil to obtain free cooling. When free cooling is available the economizer coil functions as the first stage of cooling. The economizer coil valve can be modulated to control discharge-air temperature when the economizer can meet or exceed...

 Open the catalog to page 7
OMNIZONE?-8

FRONT RETURN. TOP SUPPLY 2. VAV models (50BVJ) are rear return, top supply only. 3. Compressor, controls, and condenser access are through front panels. 4. Field power connections are 1-3/4 inches. Control connections are 7/8 inches. 5. Optional blower orientation is selected in model number nomenclature as option 9 in FIOP section Shows recommended minimum service clearances. MOTOR ANDC BELT ACCESS (BOTH SIDES) RIGHT SIDE VIEW REAR RETURN. FRONT SUPPLY LEFT SIDE VIEW FRONT VIEW REAR RETURN. TOP SUPPLY MOTOR AND^. BELT ACCESS (BOTH SIDES) LEFT SIDE VIEW FRONT RETURN. REAR SUPPLY RIGHT SIDE VIEW...

 Open the catalog to page 8
OMNIZONE?-9

FRONT RETURN. TOP SUPPLY VAV models (50BVK) are rear return, top supply only. Compressor, controls, and condenser access are through front panels. Field power connections are 1-3/4 inches. Control connections are 7/8 inches. Liquid line connections are 7/8 in. OD. 7. Optional blower orientation is selected in model number nomenclature as option 9 in FIOP section (digits 15 and 16). RECOMMENDED CONDENSER MATCHES: X/P/PX Shows recommended minimum service clearances. REAR RETURN, FRONT SUPPLY RIGHT SIDE VIEW LEFTSIDE VIEW REAR RETURN. TOP SUPPLY OPTIONAL STANDARD LEFT SIDE VIEW FRONT RETURN, REAR...

 Open the catalog to page 9

All Carrier| Commercial Systems North America catalogs and technical brochures

  1. Axis™

    2  Pages

Archived catalogs

  1. 50ZPB

    4  Pages

  2. AHUBuilder

    2  Pages

  3. 39CC

    2  Pages

  4. 48XL-A

    30  Pages

  5. 48PM CENTURION?

    64  Pages

  6. 48PG CENTURION?

    107  Pages

  7. 39L AERO®

    52  Pages

  8. 39S

    36  Pages

  9. 30RB AQUASNAP®

    92  Pages

  10. AQUAFORCE® 30XA

    150  Pages

  11. 16TJ

    32  Pages

  12. 39M AERO®

    110  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.