Connectivity Solutions
4Pages

{{requestButtons}}

Catalog excerpts

Connectivity Solutions - 1

FORE-SiGHT-E LITE® When it comes to brain protection and patient safety, hindsight is never good enough. Connectivity Solutions j*. : ihok-woi: ’ ,HT• f • fore sight ; fore-sicht Experience the enhanced performance and ease of use with FORE-SIGHT ELITE®: • First and only FDA cleared tissue oximeter utilizing a 5th wavelength of near-infrared light to reduce patient variability • Enhanced FORE-SIGHT algorithm improves accuracy to unprecedented levels (3.05% Arms)1 • Eliminates the need for pre-induction baseline reading • Detects otherwise unnoticed cerebral desaturation events 1) MacLeod D, Ikeda K, Cheng C, Shaw A. Validation of the next generation FORE-SIGHT ELITE Tissue Oximeter for adult cerebral tissue oxygen saturation. Anesth Analg 2013;116(SCA Suppl):1-182,#40. FORE-SlGHT E LITE® Accurate insight into brain oxygenation

Open the catalog to page 1
Connectivity Solutions - 2

ORBIS Philips Emergin Philips VISICU Picis SAFERsleep Siemens Surgical Information Systems Theronyz Video Output (VGA) to an External Display Any display or video system (640 x 480 capable) equipped with VGA input Patient Monitoring Systems Philips IntelliVue Patient Monitors Anesthesia Information Management Systems (AIMS) or Data Management Systems (DMS) • Philips CompuRecord • Drager Innovian® Anesthesia PDMS • Sorin DMS • Spectrum Medical Viper DMS • Terumo TLink™ DMS • iMDsoft MetaVision® • Plexus Information Systems Anesthesia Touch™ Electronic Medical Record (EMR) Systems (via...

Open the catalog to page 2
Connectivity Solutions - 3

FORE-SIGHT ELITE® Absolute Tissue Oximeter Connectivity Solutions Add an Additional External Display to the FORE-SIGHT ELITE Screen Connectivity to Patient Monitoring Systems in the OR and ICU This solution is ideal for OR environments, where both Anesthesia and Perfusion desire visibility of the FORE-SIGHT ELITE displayed information. The video output (VGA) in the FORE-SIGHT ELITE is capable of mirroring its screen on an external display, allowing another display for enhanced visualization of the StO2 measurements in the OR. FORE-SIGHT ELITE is capable of interfacing with the Philips...

Open the catalog to page 3
Connectivity Solutions - 4

Connectivity to Clinical Information Managements Systems (CIMS) Using a Clinical Information or Data Management System (DMS) to capture vital signs records during surgery and in the ICU has become standard practice in many institutions. FORE-SIGHT ELITE has the ability to connect to various CIMS or DMS. The StO2 values and messages are sent every two seconds to the CIMS for storage and analysis in the context of other vital signs. FORE-SIGHT ELITE is compatible with most EMR systems through a third party medical device integration system. The combined system enables the transmission of...

Open the catalog to page 4