Identification: The product is MIMIC Temporary Crown & Bridge Material, a dental composite resin manufactured by 3D Dental Design & Development LLC. It is classified as an irritant, causing skin and serious eye irritation.
Hazards Identification: The material is classified under GHS as causing skin and eye irritation. Precautionary measures include wearing protective gear and seeking medical advice if irritation occurs.
Composition: Key ingredients include multifunctional methacrylates (40-50%), glass/silica filler (40-45%), and polyvinyl esters (5-10%).
First Aid Measures: In case of inhalation, move to fresh air. For skin contact, wash with soap and water. If in eyes, rinse with water and seek medical attention if irritation persists. Do not induce vomiting if swallowed.
Firefighting Measures: Suitable extinguishing agents include water, dry chemical, and carbon dioxide. Firefighters should wear protective equipment and avoid inhaling fumes.
Accidental Release Measures: Ensure proper ventilation and avoid environmental release. Use protective gear during cleanup.
Handling and Storage: Avoid contact with skin and eyes. Store in a cool, ventilated area away from incompatible materials.
Exposure Controls/Personal Protection: Use appropriate protective equipment, including gloves and eye protection. Ensure proper ventilation.
Physical and Chemical Properties: The material is a tooth-colored paste with a slight odor. It is slightly soluble in water and has a flash point above 100°C.
Stability and Reactivity: Stable under normal conditions but avoid heat and incompatible materials. Hazardous decomposition products include acrylic smoke.
Toxicological Information: May cause skin sensitivity. No additional chronic toxicity or carcinogenicity information provided.
Ecological Information: Not determined for ecotoxicity, persistence, or bioaccumulation.
Disposal Considerations: Dispose of through a licensed waste disposal service. Do not dispose of with household waste.
Transport Information: Not regulated for transport.
Regulatory Information: Complies with US and Canadian regulations. No ingredients listed under SARA or Proposition 65.
Other Information: Users are responsible for ensuring a safe workplace and complying with applicable regulations.
See more

Catalog excerpts

MIMIC Temporary Crown & Bridge Material-1

MIMIC Temporary Crown & Bridge Material SECTION 1: Identification of the substance/mixture and of the supplier Product name: MIMIC Temporary Crown & Bridge Material Manufacturer/Supplier Trade name: 3D Dental Design & Development Manufacturer/Supplier Product number: Recommended uses of the product and restrictions on use: Dental composite resin. Manufacturer Details: 3D Dental Design & Development LLC 16781 Chagrin Blvd. Suite 434 Shaker Heights, OH 44120 TEL: 1-877-605-8061 Emergency telephone number: CHEMTREC: 1-800-424-9300 SECTION 2: Hazards identification Classification of the substance or mixture: Irritant Skin irritation, category 2 Eye irritation, category 2A Serious Eye Damage/Eye Irritation - Category 2A Skin irritation - Category 2 Signal word: Warning. Hazard statements: Causes skin irritation. Causes serious eye irritation. Precautionary statements: If medical advice is needed, have product container or label at hand. Keep out of reach of children. Read label before use. Wash skin thoroughly after handling. Wear protective gloves/protective clothing/eye protection/face protection. IF ON SKIN: Wash with soap and water. Specific treatment (see supplemental first aid instructions on this label). If skin irritation occurs: Get medical advice/attention. Take off contaminated clothing and wash before reuse. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. If eye irritation persists get medical advice/attention. Hazards not otherwise classified (HNOC): No additional information. Other Non-GHS Classification: WHMIS

 Open the catalog to page 1
MIMIC Temporary Crown & Bridge Material-2

Effective date: 06.16.2017 Page 2 of 6 MIMIC Temporary Crown & Bridge Material SECTION 4: First aid measures Description of first aid measures After inhalation: Move exposed to fresh air. Give artificial respiration if necessary. If breathing is difficult give oxygen. Loosen clothing and place exposed in a comfortable position. Seek medical assistance if cough or other symptoms appear. After skin contact: Rinse/flush exposed skin gently using soap and water for 15-20 minutes. Seek medical advice if discomfort or irritation persists. After eye contact: Protect unexposed eye. Rinse/flush exposed...

 Open the catalog to page 2
MIMIC Temporary Crown & Bridge Material-3

Safety Data Sheet according to 29CFR1910/1200 and GHS Rev. 3 Effective date: 06.16.2017 Page 3 of 6 MIMIC Temporary Crown & Bridge Material Advice for firefighters: Protective equipment: Wear protective eyewear, gloves, and clothing. Refer to Section 8.Use NIOSH- approved respiratory protection/breathing apparatus. Additional information (precautions): Avoid inhaling gases, fumes, dust, mist, vapor, and aerosols. Avoid contact with skin, eyes, and clothing. SECTION 6: Accidental release measures Personal precautions, protective equipment and emergency procedures: Ensure adequate ventilation....

 Open the catalog to page 3
MIMIC Temporary Crown & Bridge Material-4

Effective date: 06.16.2017 Page 4 of 6 Eye protection Wear equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).Safety glasses or goggles are appropriate eye protection. General hygienic measures: Perform routine housekeeping. Wash hands before breaks and at the end of work. Avoid contact with skin, eyes, and clothing. Before wearing wash contaminated clothing. SECTION 9: Physical and chemical properties

 Open the catalog to page 4
MIMIC Temporary Crown & Bridge Material-5

Reproductive toxicity: Safety Data Sheet according to 29CFR1910/1200 and GHS Rev. 3 Effective date: 06.16.2017 Page 5 of 6 MIMIC Temporary Crown & Bridge Material SECTION 12: Ecological information Ecotoxicity: Not determined. Persistence and degradability: Not determined. Bioaccumulative potential: Not determined. Mobility in soil: Not determined. Other adverse effects: None identified. SECTION 13: Disposal considerations Waste disposal recommendations: Contact a licensed professional waste disposal service to dispose of this material. Dispose of empty containers as unused product. Product or...

 Open the catalog to page 5
MIMIC Temporary Crown & Bridge Material-6

developmental toxicity: None of the ingredients are listed. Canada Canadian Domestic Substances List (DSL): All ingredients are listed. Canadian NPRI Ingredient Disclosure list (limit 0.1%): None of the ingredients are listed. Canadian NPRI Ingredient Disclosure list (limit 1%): None of the ingredients are listed. SECTION 16: Other information This product has been classified in accordance with hazard criteria of the Controlled Products Regulations and the SDS contains all the information required by the Controlled Products Regulations. Note: The responsibility to provide a safe workplace remains...

 Open the catalog to page 6

All CavoMed / 3D Dental catalogs and technical brochures

  1. VPS Putty

    9  Pages

  2. P-GPC

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.