PrO-Hospital
1 /88Pages

PrO-Hospital

PrO-Hospital
1 /88Pages

Catalog excerpts

PrO-Hospital-1

PrO-Hospital a division of Scientific Limited Clinical, Hospital & Medical Laboratories

 Open the catalog to page 1
PrO-Hospital-2

Welcometo our latest Centrifuge range Centrifuges focused on the future Micro, small, medium, large & floor ambient with additional refrigerated versions. Improved angled front panel for ease of use. Improved rotors for safer sample use Additional rotors, fixed angles, high speed fixed angles, swing out and micro. Fixed angle rotors are now supplied with sealed lids, for ultimate safety. Swing out rotors also have new sealed lids to increase their capacity. Next generation components • Inverter • Efficient with added power 33% better acelleration/decelleration • Tachometer /Imbalance • Third...

 Open the catalog to page 2
PrO-Hospital-3

Selection of rotors available PCVs Ambient & PCVsR. Refrigerated PCVA Ambient & PCVRA. Refrigerated PCV6A Ambient & PCV6RA. Refrigerated PCV13 Ambient Haematocrit centrifuge PCVSO Ambient Centrifuge Complete with Micro Rotor 12 Complete with Fixed angle rotor 14 Complete with Haematocrit rotor 16 Complete with swing out rotor 17 HLFS4 Ambient & HLFS4R. Refrigerated Selection of rotors available HLFS4A Ambient & HLFS4RA. Refrigerated Complete with Swing out rotor 85

 Open the catalog to page 3
PrO-Hospital-4

Micro Centrifuges to 0.2Litre maxPrime multi rotor CentrifugeAmbient Centrifuge Speed Rcf Max Timer Dims HWD Weight Power Memory Accel rates Decel rates 15,000 Rpm max (10Rpm steps) 10 - 22,000G 0-9 Hours & Hold (30 sec steps) 280 x 240 x 360mm 12.8 Kg (without rotor) 125 Watts 99 programs 10 programs 10 programs PART NUMBERS PCVs (230V50/60Hz) 1.PCVs (110V 60Hz) (Rotor required see the following pages Refrigerated Centrifuge PART NUMBERS Speed Rcf Max Timer Dims HWD Weight Power Memory Accel rates Decel rates Temp range 15,000 Rpm max (10Rpm steps) 10 - 22,000G 0-9 Hours & Hold (30 sec steps)...

 Open the catalog to page 4
PrO-Hospital-5

Sample tube angle ° 45 45 45 45 Rotor Part number Tube size max Part number Tube size max

 Open the catalog to page 5
PrO-Hospital-6

Micro rotors to 22,000 Rcf (G) Sealed lid included BRK5463 BRK5464 Rotor type Tube size max Minimum Rcf (G) Maximum Rcf (G) Maximum Rpm Radius max cms Sample tube angle ° Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency) Minimum Temperature @ 23°C Reducers pack of 4 Rotor Part number Part number

 Open the catalog to page 6
PrO-Hospital-7

Rotor type Tube size max Minimum Rcf (G) Maximum Rcf (G) Maximum Speed Radius max cms Sample tube angle ° Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency) Minimum Temperature @ 23°C Rotor Part number Tube size max Part number Tube size max Rotor Part number Tube size max Part number Tube size max

 Open the catalog to page 7
PrO-Hospital-8

BRK5508S Rotor Buckets supplied (set of 8) Capacity 8 x 5ml Sample tube angle ° 0 Acceleration time (secs) 15 Deceleration time (secs) 15

 Open the catalog to page 8
PrO-Hospital-9

Rotor type Tube size max 24 x capillary & 12 x 2ml Sample tube angle ° 0 & 60 Acceleration time (secs) 20 Deceleration time (secs) 20 Description Plain Capillary tubes pack 10 x 100 Heparanised Capillary tubes pack 10 x 100 Sealing Clay Pk 10 Rim seal Gasket Pk 10 Replace regularly every 2 months Part Number Description 8003 PCV Reader

 Open the catalog to page 9
PrO-Hospital-10

Tube size max Single or double Sample tube angle ° 0 Acceleration time (secs) 20 Deceleration time (secs) 20 Cytology rotor includes Rotor, Sealed Lid, Clips, 24 holders with filter card & 100 slides Stainless steel clip Double sample holder with card (up to 1ml) Single sample holder with card (up to 1ml) Single sample holder with card (up to 6ml)

 Open the catalog to page 10
PrO-Hospital-11

Refrigerated Centrifuges Dynamics rooted in innovation Accuracy and control using less power. How? Centurion Scientific Ltd keep the compressor running constantly, sounds odd but this method increases compressor life and reduces power dramatically. Constantly turning a compressor on and off means a huge surge of power on each action, plus poor temperature control. See graph below, to control the accuracy to an unprecedented level we balance and control with a heater. This is controlled by a PID system offering top level control. Why? Imagine using a shower, you turn on both hot water and cold...

 Open the catalog to page 11
PrO-Hospital-12

Speed Rcf Max Timer Dims HWD Weight Power Memory Accel rates Decel rates 15,000 Rpm max (10Rpm steps) 10 - 22,000G 0-9 Hours & Hold (30 sec steps) 280 x 240 x 360mm 12.8 Kg (without rotor) 125 Watts 99 programs 10 programs 10 programs PART NUMBERS (230V50/60HZ) PCVA with BRK5424 rotor PCVB with BRK5436 rotor PCVC with BRK5448 rotor PCVD with BRK5494 rotor PART NuMBERS (110V 60Hz) 1.PCVA with BRK5424 rotor 1.PCVb with BRK5436 rotor 1.PCVC with BRK5448 rotor 1.PCVD with BRK5494 rotor Refrigerated Centrifuge Speed Rcf Max Timer Dims HWD Weight Power Memory Accel rates Decel rates Temp range 15,000...

 Open the catalog to page 12
PrO-Hospital-13

Sample tube angle ° 45 45 45 45 Rotor Part number Tube size max Part number Tube size max

 Open the catalog to page 13
PrO-Hospital-14

Micro Centrifuges to 0.2Litre maxDual Rotor Centrifuges Complete with rotor Ambient Centrifuge Speed Rcf Max Timer Dims HWD Weight Power Memory Accel rates Decel rates 6,000 Rpm max (10 Rpm steps) 10 - 3,500 G 0-9 Hours & Hold (30 sec steps) 280 x 240 x 360mm 12.8 Kg (without rotor) 125 Watts 99 programs 10 programs 10 programs Refrigerated Centrifuge Speed Rcf Max Timer Dims HWD Weight Power Memory Accel rates Decel rates Temp range 6,000 Rpm (10 Rpm steps) 10 - 3,500 G 0-9 Hours & Hold (30 sec steps) 320 x 280 x 575mm 41.8 Kg (without rotor) 575 Watts 99 programs 10 programs 10 programs -20C...

 Open the catalog to page 14
PrO-Hospital-15

Rotor type 8 x 15ml tube Sample tube angle ° 30 Acceleration time (secs) 20 Deceleration time (secs) 20 Rotor Part number Tube size max Part number Tube size max Rotor Part number Tube size max Part number Tube size max

 Open the catalog to page 15
PrO-Hospital-16

Micro Centrifuge with Haematocrit rotor Dual Rotor Centrifuge Complete with rotor Ambient Centrifuge Speed Rcf Max Timer Dims HWD Weight Power Memory Accel rates Decel rates 13,000 Rpm max (10 Rpm steps) 10 - 15,800 G 0-9 Hours & Hold (30 sec steps) 280 x 240 x 360mm 12.8 Kg (without rotor) 125 Watts 99 programs 10 programs 10 programs Rotor BRK5401 Rotor type 24 x capillary & 12 x 2ml Sample tube angle ° 0 & 60 Acceleration time (secs) 20 Deceleration time (secs) 20

 Open the catalog to page 16

All Centurion Scientific catalogs and technical brochures

  1. PrO-PRP

    8  Pages

  2. PrO-Cytology

    8  Pages

  3. PrO-Oiltest

    12  Pages

  4. PrO-Xtract

    20  Pages

  5. PrO-Vet

    28  Pages

  6. PrO-Cyt

    8  Pages

  7. PrO-CW

    4  Pages

  8. PrO-Eazy

    20  Pages

  9. K243/K243R

    12  Pages

  10. K242/K242R

    12  Pages

  11. CR4000

    3  Pages

  12. K2015/K2015R

    8  Pages

  13. CW12

    4  Pages

  14. K241

    2  Pages

  15. CR2000

    2  Pages

  16. C2041

    1  Page

  17. C2006

    1  Page

  18. C2004

    1  Page

  19. C2015

    1  Page

  20. C2012

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.