PrO-Vet
1 / 28Pages

Catalog excerpts

PrO-Vet - 1

PrO-VET a division of Scientific Limited PCV, Serum, Faeces, Sperm & Cytology

Open the catalog to page 1
PrO-Vet - 2

Welcometo our PrO-VET Centrifuge range Simple and safe to use. Our centrifuges offer ease of use. LID Models offer 4 pre written programs ■ All the 4 programs have been pre-set for ease of use ■ Press Function and select 1 of 4 parameters ■ Load your samples, shut the lid and press Start ■ Easy and reliable • LED models are also available for more complex requirments allowing full user programming • Multiple features • Long Lifetime for confidence of purchase • Run finish buzzer. (Can be turned off) • Full safety features for safe and confident use • Space saving and quiet • Equine & Bovine...

Open the catalog to page 2
PrO-Vet - 3

Small animals Medium size animals PrO-Vet PCV.s Dual. Haematocrit & Fixed angle centrifuge Sperm Faeces Cytology/Histology Urine All rotors (not cytology) PrO-Vet Serum.FA4 PrO-Vet Serum.FA8 PrO-Vet Serum.s Fixed angle rotor centrifuge Fixed angle rotor centrifuge Dual. Fixed angle rotor centrifuge

Open the catalog to page 3
PrO-Vet - 4

Micro Centrifuge Supplied with Haematocrit rotor HE Ambient Centrifuge Programs Display indicative only PART nuMBERS. (230V 50/60Hz) PrO-VET.HE. With BRK5401 rotor Part numbers. (110V 60Hz) 1.PrO-VET.HE. With BRK5401 rotor Rotor type Tube size max Minimum Rcf (G) Maximum speed Rpm Maximum Rcf (G) Radius max cms Sample Tube angle ° Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency)

Open the catalog to page 4
PrO-Vet - 5

Micro Centrifuge Supplied with Swing out rotor SO Ambient Centrifuge Programs Display indicative only PART nuMBER. (230V50/60Hz) PrO-VET.SO. With BRK5508S rotor Rotor type Tube size max Minimum Rcf (G) Maximum speed Rpm Maximum Rcf (G) Radius max cms Sample Tube angle ° Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency)

Open the catalog to page 5
PrO-Vet - 6

Micro Centrifuge Supplied with Haematocrit rotor and Swing out rotor PCV.h Ambient Centrifuge Program 1 Speed 1. PCV 2. Serum 1 3. Serum 2 4. Urine HWD Weight Power Time 300 secs 600 secs 300 secs 300 secs Display indicativeonly PART NuMBERS. (230V 50/60Hz) PrO-VET.PCVh. With BRK5401 rotor and with BRK5508S rotor PART NuMBERS. (110V 60Hz) l.PrO-VET.PCVh. With BRK5401 rotor and with BRK5508S rotor Rotor BRK5401 Rotor type Tube size max Minimum Rcf (G) Maximum speed Rpm Maximum Rcf (G) Radius max cms Sample Tube angle ° Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency)

Open the catalog to page 6
PrO-Vet - 7

Program 2 Speed Time 1. Serum fast 4,000Rpm 300 secs Rotor type Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency)

Open the catalog to page 7
PrO-Vet - 8

Micro CentrifugeSupplied with Fixed angle rotor FA4 Ambient Centrifuge Programs 1. Serum fast 2. Serum 1 3. Urine 4. Sperm HWD Weight Power Time 240 secs 300 secs 420 secs 480 secs Display indicative only PART NuMBERS. (230V 50/60Hz) PrO-VET.FA4. With BRK5404 rotor PART NuMBERS. (110V 60Hz) 1.PrO-VET.FA4. With BRK5404 rotor Rotor BRK5404 Rotor type Tube size max Minimum Rcf (G) Maximum speed Rpm Maximum Rcf (G) Radius max cms Sample Tube angle ° Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency)

Open the catalog to page 8
PrO-Vet - 9

Programs 1. Serum fast 4. Urine HWD Weight Power Display indicative only PART NuMBER. (230V50/60Hz)PrO-VET.FA8. With BRK5407 rotor PART NuMBER.(110V 60Hz) Time 180 secs 300 secs 300 secs 300 secs Rotor Rotor type Tube size max Minimum Rcf (G) Maximum speed Rpm Maximum Rcf (G) Radius max cms Sample Tube angle ° Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency)

Open the catalog to page 9
PrO-Vet - 10

Micro Centrifuge Supplied with Fixed angle rotors Serum.s Ambient Centrifuge Program 1 Display indicative only PART nuMBERS. (230V 50/60Hz) PrO-VET.Serum s. With BRK5404 rotor and with BRK5407 rotor Part numbers. (110V 60Hz) 1.PrO-VET.Serum s With BRK5404 rotor and. With BRK5407 rotor Rotor type Tube size max Minimum Rcf (G) Maximum speed Rpm Maximum Rcf (G) Radius max cms Sample Tube angle ° Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency)

Open the catalog to page 10
PrO-Vet - 11

11 Program 2 Speed Time 1. Serum fast 8,000Rpm 180 secs Rotor type 30 Acceleration time (secs) 25 Deceleration time (secs)

Open the catalog to page 11
PrO-Vet - 12

Micro Centrifuge Supplied with Haematocrit rotor and Fixed angle rotorPCV.s Ambient Centrifuge Program 1 1. PCV 2. Serum 1 3. Serum 2 4. Urine HWD Weight Power Time 300 secs 600 secs 300 secs 300 secs PrO-VET.PCV s. With BRK5401 rotor and with BRK5408 rotor l.PrO-VET.PCV s. With BRK5401 rotor and with BRK5408 rotor Acceleration time (secs) 25 Deceleration time (secs) 25

Open the catalog to page 12
PrO-Vet - 13

Program 2 Speed Time 1. Serum fast 6,000Rpm 240 secs Rotor type Tube size max Minimum Rcf (G) Maximum speed Rpm Maximum Rcf (G) Radius max cms Sample Tube angle ° Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency)

Open the catalog to page 13
PrO-Vet - 14

Small Multi Centrifuge & Supplied with Haematocrit rotor 14 k and Swing out rotor Multi Ambient Centrifuge Display indicative only I.PrO-VET.Multi with BRK5401 rotor and With BRK5506 swing out rotor Ambient Centrifuge Programs Speed Time Ambient Centrifuge BRK5506 Programs Speed Time 1. Serum fast 4,000Rpm 300 secs

Open the catalog to page 14
PrO-Vet - 15

15 Included Rotor type 24 x capillary & 12 x 2ml Acceleration time (secs) 20 Deceleration time (secs) 20

Open the catalog to page 15
PrO-Vet - 16

Adaptors required, see following page. ( 1 set included) Rotor type Tube size max Minimum Rcf (G) Maximum speed Rpm Maximum Rcf (G) Radius max cms Sample Tube angle ° Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency)

Open the catalog to page 16
PrO-Vet - 17

Tube type: Micro with cap. Shape: Point! Tube type: Plain no cap. Shape: Round Tube type: Falcon with cap. Shape: Point Tube type: Falcon with cap. Shape: Square Tube type: Nalgene. Oakridge with cap. Shape: Round Tube type: Monovette. Shape Square Tube type: Vacutainer. Shape: Round Tube type: Vacuette. Shape: Round

Open the catalog to page 17
PrO-Vet - 18

Programs Speed Time Programs Speed Time 1. Serum fast 4,000Rpm 300 secs Display indicative only PART NuMBERS. (230V 50/60Hz) PrO-VET.Equine so. With BRK5508M rotor PART NuMBERS. (110V 60Hz) l.PrO-VET.Equine so. With BRK5508M rotor Rotor type Acceleration time (secs) Deceleration time (secs) Autoclavable (frequency)

Open the catalog to page 18
PrO-Vet - 19

Cyto Ambient CentrifugePrograms 1. Low 4. Maximum HWD Weight Power Display indicative only Time 600 secs 600 secs 500 secs 500 secs PART NuMBER. (230V50/60Hz)PrO-VET.Cyto. With BRK5940 rotor PART NuMBER.(110V 60Hz) l.PrO-VET.Cyto. With BRK5940 rotorBRK5940 Rotor type Tube size max Minimum Rcf (G) Maximum speed Rpm Acceleration time (secs) 20 Deceleration time (secs) 20

Open the catalog to page 19

All Centurion Scientific catalogs and technical brochures

  1. PrO-PRP

    8 Pages

  2. PrO-Cytology

    8 Pages

  3. PrO-Oiltest

    12 Pages

  4. PrO-Xtract

    20 Pages

  5. PrO-Cyt

    8 Pages

  6. PrO-CW

    4 Pages

  7. PrO-Eazy

    20 Pages

  8. PrO-Hospital

    88 Pages

  9. K243/K243R

    12 Pages

  10. K242/K242R

    12 Pages

  11. CR4000

    3 Pages

  12. K2015/K2015R

    8 Pages

  13. CW12

    4 Pages

  14. K241

    2 Pages

  15. CR2000

    2 Pages

  16. C2041

    1 Pages

  17. C2006

    1 Pages

  18. C2004

    1 Pages

  19. C2015

    1 Pages

  20. C2012

    1 Pages