1. Catalogs
  2. Chattanooga USA
  3. Intelect Legend Stim Specifications

Intelect Legend Stim Specifications

Intelect Legend Stim Specifications

Product catalog summary
Stim Output Parameters Overview
This document outlines the specifications for the Intelect Legend Stim device, focusing on different stimulation modes: Interferential, Premodulated, Russian, and High Volt. Each mode has specific parameters that define its operation and application.

Interferential and Premodulated Modes
  • Carrier Frequency: Both modes operate at 5000 Hz.
  • Beat Frequency: Adjustable between 0-200 Hz.
  • Scan Mode: Available for Interferential with a 15-second scan time; not applicable for Premodulated.
  • Sweep Time: 15 seconds for both modes.
  • Amplitude: Ranges from 0-50 mA RMS.
  • Voltage: Maximum of 200 Volts.
  • Treatment Time: Adjustable from 1 to 60 minutes.

Russian Mode
  • Carrier Frequency: 2500 Hz.
  • Burst Frequency: Ranges from 20-100 BPS.
  • Duty Cycle: Adjustable between 10-50%.
  • Ramp Up/Down: Options include 5, 1, 2, and 5 seconds.
  • Cycle Time: Various options including 5/5, 10/10, 10/20, 4/12, 10/30, 0/50, and Continuous.
  • Amplitude: 0-100 mA RMS into a 500-ohm load.
  • Voltage: Maximum of 200 Volts.
  • Treatment Time: 0-60 minutes.

High Volt Mode
  • Pulse Frequency: Ranges from 10-120 pps.
  • Polarity: Positive (+) and Negative (-) options available.
  • Amplitude: Up to 500 mA RMS.
  • Voltage: Maximum of 0-500 Volts.
  • Output Current: Up to 0-2500 mA Peak.
  • Treatment Time: 0-60 minutes.

General Notes
  • Parameters marked as N/A indicate that they are not applicable for the specific mode.
See more

Catalog excerpts

Intelect Legend Stim Specifications-1

Stim Output Parameters Intelect Legend Stim Specifications Carrier Frequency Beat Frequency Scan Mode Scan Time Sweep Time Duty Cycle Ramp Up / Ramp Down Cycle Time Alternating Time in Seconds Treatment Time Function Mode Carrier Frequency Pulse Frequency Burst Frequency Phase Duration Interphase Interval Duty Cycle Ramp Up / Ramp Down Cycle Time Output Current Treatment Time Single, Recipr. High volt Electrodes, Probes AIROAST ©Chattanooga CMRSH HompeX' djOSUrgical DoTsDpy «*Empi PfraCAHE

 Open the catalog to page 1

All Chattanooga USA catalogs and technical brochures

  1. Mobile 2 RPW

    4  Pages

  2. Chatt-Tape

    4  Pages

Archived catalogs

  1. Moveo XP

    5  Pages

  2. primera

    2  Pages

  3. Hot and Cold

    12  Pages

  4. Iontophoresis

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.