Open the catalog to page 1Chengdu Headquarter Beijing R&D Center Beijing Factory Chengdu Novel Medical Equipment Co., Ltd. was established in June 2011, and co-founded by Hong Kong patriotic industrialist Mr. Chao Kuang Piu and Tsinghua University. Focusing on the field of nuclear medicine and nuclear security, Novel Medical has launched China's first and world's leading Clinical PECT/CT, Preclinical PET/SPECT/CT, intelligent nuclear radiation monitoring systems, etc. Novel Medical aims to e nsure that everyone benefits from adv ancements in nuclear technology, contribute to the innovative development of China 's nuclear...
Open the catalog to page 2Novel Medical - Product Series Preclinical animal PET/SPECT/CT
Open the catalog to page 3The only China-made SPECT/CT Intrinsic Spatial Resolution (CFOV) Intrinsic Energy Resolution Intrinsic Spatial Linearity (CFOV, Differential) System spatial 7.4mm resolution 7.3mm without scatter (LEHR, @10cm) Intrinsic Uniformity (CFOV) D: Differential I: Integral Maximum Count Rate per Detector Novel Medical
Open the catalog to page 4High-flux SPECT detector High-flux Tsinghua University’s high-flux technology solution: Front-end electronics: ultra-sensitive amplification circuit to suppress noise Mid-section electronics: multi-channel ADC module for efficient and accurate restoration of photoelectric signals Back-end electronics: advanced FPGA technology for real-time signal processing Datasheet Novel Medical Maximum Count Rate Energy Range Intrinsic Spatial Resolution (CFOV,FWHM) Intrinsic Spatial Resolution (CFOV,FWTM) Intrinsic Uniformity (CFOV,Differential) Intrinsic Uniformity (CFOV,Integral) Intrinsic Spatial Linearity...
Open the catalog to page 5Small-hole array design, hexagonal matrix structure offers precise positioning and high sensitivity. Innovation of the MPH collimator: significatly improved the imaging of small organs. Brand G Brand S Medical - Normalized volume sensitivity (s-y(kBq/cm2)) Reconstructed spatial resolution (mm) System planar sensitivity: cpm/^Ci System spatial resolution: mm
Open the catalog to page 6NovelCardiac© Advanced Cardiac Technology Normalized volume sensitivity: increase by 5 times Multi-pinhole confocal imaging Enter scanning mode. Double-layer board patented technology fast reconstruction locate centre of heart Reconstructed spatial resolution increase by 3 times
Open the catalog to page 7NovelCardiac© Advanced Cardiac Technology First Line: MPH Acquisition, 5 minutes (same First Column: MPH Acquisition, 5 minutes (same activity) Second Line: LEHR Acquisition, 20 minutes Second Column: Brand G Dedicated Cardiac (same activity) Scanner Acquisition, 5 minutes (same activity) Third Column: Model D Dedicated Cardiac Scanner Acquisition, 5 minutes (same activity) The MPH collimator boasts superior spatial resolution and sensitivity, providing imaging quality that surpasses the LEHR parallel-hole collimator and is comparable to that of dedicated car
Open the catalog to page 824-slice 32-layer high-performance CT Up to 24 rows of rare earth ceramic detectors Magnetic levitation brushless slip ring Ø Stable data transmission, maintenance-free Ø Maximum rotation speed of 0.54s, reduced Ø Ultra-high CT spatial resolution of 17.8 lp/cm Ø AEC automatic exposure control technology Ø Minimum scan slice thickness: 0.625 mm acquisition time Up to 32-layer low-dose iterative noise reduction algorithm Ø Superior image quality Ø Reduces patient scan dose Ø Efficient metal artifact reduction reconstruction algorithm Ø LISA iterative noise reduction algorithm, improves image c
Open the catalog to page 9NovelSharp© advanced bone scanning technology NovelSharp© Ray Tracing Reconstruction Algorithm More clearly and accurately restoring the distribution of drugs Non-destructive model: millions of high-density multi-ray tracing Back-projection data calculation: computing the data for each detector element to accurately reconstruct the image Photon scattering correction Volume effects correction Detector blur correction Collimator blur correction CT attenuation correction Size of projection matrix NovelSharp© iteration time Produce clearer images within FBP the standard acquisition time. Generate...
Open the catalog to page 10NovelQuant© quantitative technology SUV(standard uptake value) commonly used to distinguish between benign and malignent tumors measure count distribution Partial volumetric effect Collimator-Detector response correction Scattering correction measure activity distribution Attenuation correction True activity distribution Partial volumetric effect correction standard uptake value distribution SUV=radioactivity concentration of the lesion(kBq/ml)/(injection dose(MBq)/weight(kg)) recovery coefficients comparison
Open the catalog to page 11Bilateral Absorbed Absorbed Renal Dose Dose |NovelTomo©Advanced Renal Scanning Technology Dual-probe independent control technology Simultaneous renal dynamic acquisition and tomographic acquisition (renal depth calculation) Intelligent extraction of renal depth to improve GFR accuracy Features strong applicability, high precision, and good safety
Open the catalog to page 12Comprehensive Clinical Application Full coverage of nuclear medicine imaging Whole-body bone imaging Kidney tomographic imaging Bone tomographic imaging Thyroid imaging Partial bone imaging Iodine-131 nail carcinoma whole-body scintigraphy Renal dynamic imaging Parathyroid imaging
Open the catalog to page 13Comprehensive Clinical Application Full coverage of nuclear medicine imaging Myocardial perfusion imaging Liver dynamic imaging Gastric emptying imaging
Open the catalog to page 14Comprehensive Clinical ApplicationFull coverage of nuclear medicine imaging 177Lu whole body imaging Bone tomosynthesis imaging Sentinel lymph node imaging
Open the catalog to page 15SPECT, SPECT/CT - installations (renowned hospitals) SPECT/CT: Peking Union Medical College Hospital Affiliated Hospital of Inner Mongolia Medical University First Hospital of Shanxi Medical University Affiliated Hospital of Southwest Medical University Beijing Friendship Hospital, Capital Medical University Chongqing University Cancer Hospital (Chongqing Cancer Institute) Foshan Second People's Hospital THE FIRST AFFILIATED HOSPITAL OF SHIHEZI UNIVERSITY SPECT: First Affiliated Hospital of Shihezi University Beijing Tsinghua Changgung Hospital Peking University First Hospital 541 General Hospital...