Chengji Emslim CJ-EMS-4

Chengji Emslim CJ-EMS-4
1 / 14 PagesView full catalog

Chengji Emslim CJ-EMS-4

Product catalog summary

Product Overview

The Mathews HI-EMT instrument uses High Energy Focused Electromagnetic Waves technology to induce intense muscle contractions, promoting muscle growth and fat reduction. It operates within a frequency range of 5-100Hz, powered by 3000W at 220V 50Hz, and features a 15.6-inch display.

1. Instrument Specifications

  • Technology: HI-EMT for muscle training and body shaping.
  • Parameters: Frequency 5-100Hz, Power 3000W, Power supply 220V 50Hz.
  • Physical Features: Handle jacks, power cord jack, switch, IC data card, anti-counterfeiting sign, grey color.

2. Safety Precautions

Before Use

  • Hydrate after use; avoid feeling full during operation.
  • Remove all metal jewelry.
  • Start at lowest energy level, increase gradually based on tolerance.
  • Ensure probe is vertically in contact with skin before powering on.
  • Do not eat or drink during operation; wait at least one hour after meals.

Contraindications

  • Patients with heart disease, pacemakers, cancer, infectious diseases, cerebrovascular disease, diabetes, recent major surgery.
  • Pregnant, breastfeeding, or menstruating women.
  • Individuals with wounds or metal implants.

During and After Use

  • Maintain skin hydration and sun protection.
  • Avoid hot springs and saunas for three days post-treatment.
  • Follow a reasonable diet and sleep schedule.

3. Instrument Interface and Operation

  • Start/Pause button to access settings.
  • Independent adjustment of handles A and B for strength and duration.
  • Energy and mode settings customizable by user age, gender, and treatment area.
  • Additional controls for sound, brightness, and language.

4. Maintenance and Repair

  • Daily inspection of power cords and device condition.
  • Clean with damp cloth and mild detergent regularly.
  • Replace fuses only when powered off and unplugged to avoid electric shock.
  • Managers should conduct regular inspections of instruments and components.

5. Common Faults and Troubleshooting

  • Check power connection, switch, and fuse if device fails to operate.
  • Inspect probes and working heads for damage or incorrect installation.
  • Unauthorized repairs or dismantling void warranty and are discouraged.

6. Manufacturer's Responsibilities and Warranty

  • Main instrument body covered by a one-year warranty (excluding consumables and accessories).
  • Accessories covered by a three-month warranty.
  • Warranty void if instructions are not followed or damage is man-made.
  • Life-long maintenance and technical support available; fees apply post-warranty.
  • Replacement within 7 days possible if quality issues arise and appearance is intact.

7. Storage and Transportation

  • Store in original packaging in a dry, ventilated area away from harmful gases and flammable materials.
  • Transport carefully to avoid vibration, shock, moisture, and exposure to corrosive or explosive substances.
  • Suitable for road, rail, air, and water transport with proper packaging.

8. Accessories

  • Includes power cable, handles, manual, and other essential components.

Critical Notes and Best Practices

  • Strictly follow operating instructions to ensure safety and device reliability.
  • Only company-approved qualified personnel should perform installation, maintenance, and repairs.
  • Use original accessories to maintain warranty and avoid adverse effects.
  • Users bear responsibility for damage caused by improper use or unauthorized modifications.

Warranty and Return Shipping Policy

Within six months of delivery, the buyer pays return shipping costs; the seller covers return shipping after repair. Beyond six months, the buyer bears all shipping costs for returns and repairs.

Warranty Card Instructions

The warranty card must be completed by both buyer and seller during returns for repair and accompany the instrument. It is returned to the buyer after repair and should be kept safely.

Warranty Limitations and Exclusions

  • No free warranty for failures due to unauthorized disassembly or modification.
  • Failures from lack of reasonable maintenance are excluded.
  • Accidental damage such as falls is not covered.

Additional Information

The document includes fields for product name, purchase and return dates, contact details, maintenance company, shipping address, and remarks related to warranty and repair processes.

See more

Catalog excerpts

Chengji Emslim CJ-EMS-4-1

Machine Translated by Google MEIXIUSI Product ManualCHANPINGSHUOMINGSHU * Users should read this instrument manual carefully before ODeratina this "■•'■'duct

 Open the catalog to page 1
Chengji Emslim CJ-EMS-4-2

Machine Translated by Google Mathews Product Manual First of all, I would like to express my heartfelt thanks to the customers who purchased our instruments. This manual is for customers to It is written for the better use of this instrument, in order to use the instrument correctly and to prevent injury to the operator and the user. To protect the instrument from damage and avoid unnecessary property damage, please read the manual carefully before use. The company only considers it responsible for the safety and reliability of the instrument in the following cases: Reinstallation, improvement...

 Open the catalog to page 2
Chengji Emslim CJ-EMS-4-3

Machine Translated by Google Mathews Product Manual

 Open the catalog to page 3
Chengji Emslim CJ-EMS-4-4

Mathews Product Manual 1.1 The principle of the instrument: Using HI-EMT (High Energy Focused Electromagnetic Waves) technology to continuously expand and contract muscles, perform extreme training, make muscles Deep remodeling of the internal structure, i.e. the growth of myofibrils (muscle enlargement) and the creation of new protein chains and muscles Fibers (muscle hyperplasia) to train and increase muscle density and volume. The 100% extreme muscle contraction of HI-EMT technology can trigger a large amount of lipolysis, and fatty acids are composed of triglycerides. It is decomposed and...

 Open the catalog to page 4
Chengji Emslim CJ-EMS-4-5

Machine Translated by Google Mathews Product Manual Anti-counterfeiting sign handle jack power cord jack

 Open the catalog to page 5
Chengji Emslim CJ-EMS-4-6

Mathews Product Manual , Notes 2 > Do not feel full when using, at least one hour after meals > Remove any metal jewelry you wear before using the instrument > Before starting the operation, touch the probe vertically to the skin, and then turn on the main unit switch, Adjust the operating mode energy to the lowest, and then increase the energy sequentially according to the user's skin tolerance > Do not eat or drink water during the operation, try to eat after one hour after the operation > Those who have wounds on the skin, or avoid wounds for use; > Patients with heart disease (eg, those with...

 Open the catalog to page 6
Chengji Emslim CJ-EMS-4-7

Machine Translated by Google Mathews Product Manual 3. Instrument interface operation process 3.0 Start interface Settings button * The operation interface of mode 1 is as shown below (3.1): Start/Pause (click for the first time to enter the setting page, as shown in Figure 3.2) The AB handle can be selected independently, and the strength/time of the handle can be adjusted according to different customers. Click the start/stop button to operate Adjustment time Handle B strength adjustment Handle A Strength Adjustment

 Open the catalog to page 7
Chengji Emslim CJ-EMS-4-8

Machine Translated by Google Mathews Product Manual According to different levels of age, gender, location Confirm that the type selection is complete, click to enter the main page, and energy selection can be performed as shown in Figure 3.3. 3.3 Energy setting start Work progress halo Stop (click and stop working, the interface can jump to Figure 3.1)

 Open the catalog to page 8
Chengji Emslim CJ-EMS-4-9

Machine Translated by Google Mathews Product Manual * The setting operation interface is as follows (Figure 3.6.1): Sound adjustment settings

 Open the catalog to page 9
Chengji Emslim CJ-EMS-4-10

Machine Translated by Google Mathews Product Manual Brightness adjustment settings Instrument parameters

 Open the catalog to page 10
Chengji Emslim CJ-EMS-4-11

Machine Translated by Google Mathews Product Manual language settings Managers must regularly inspect instruments and components. Whether the power socket has a reliable connection to the ground. Please check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged. Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning of the equipment. Can be powered off in the instrument Next, wipe the device case with a damp cloth, soapy water or a mild detergent. *When replacing the fuse, in order to prevent electric...

 Open the catalog to page 11
Chengji Emslim CJ-EMS-4-12

Mathews Product Manual After purchasing the instrument, you need to fill i n the warranty card and send it to the manufacturer or agent to have the warranty effect; From the date of issuance of the bill, the mainframe of the company's product quality problems is guaranteed for one year free of charge (Note: with the purchase bill and warranty card warranty; the scope of warranty here is i imited to the main body of the instrument, excluding accessories, which need to be replaced regularly consumables). After the warranty period has expired, please contact the manufacturer directly to provide...

 Open the catalog to page 12
Chengji Emslim CJ-EMS-4-13

Mathews Product Manual 7. Storage and transportation management > Storage: The instrument should be stored in the original packing box, placed in a well-ventilated room, and the packing box should be padded. The ambient temperature is -10y~40y, the relative humidity is not more than 93%, it is not allowed to be placed in harmful gas, flammable, Around explosive substances and corrosive gases. > Transportation: The instrument in the packaged condition is suitable for road, rail, air and water transportation, during loading and unloading and transportation Vibration and shock shall be prevented...

 Open the catalog to page 13
Chengji Emslim CJ-EMS-4-14

Mathews Product Manual 1. The machine can be replaced only if there is a quality problem within 7 days from the date of purchase (with the receipt) and the appearance is intact. One machine, the main engine is guaranteed for one year (except for wearing parts), other non-warranty scope or the warranty period has expired, also It can be responsible for maintenance and update, and the maintenance fee needs to be charged appropriately. If the instrument fails, it needs to be sent back for maintenance. Within six months from the date of delivery, the buyer shall bear the return shipping cost, and...

 Open the catalog to page 14

All Chengji Electronic Technology catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.