DEFINING TOMORROW'S AESTHETICS Please read through the user manual before operating this machine
Open the catalog to page 1First of all, I would like to express my heartfelt gratitude to the customers who purchased ourequipment. This manual is for customers to better use this machine The instrument is written in order to use the instrument correctly, prevent injury to the operator and user, and protect the instrument from damage TO AVOID UNNECESSARY PROPERTY LOSS, PLEASE READ THE MANUAL CAREFULLY BEFORE USE. Namely: assembly operation, heavy equipment Adjustments, improvements and maintenance are all carried out by personnel approved by our company, and the electrical equipment connected to this instrument meets...
Open the catalog to page 2This product must be used in accordance with the use methods in this manual, and all the methods caused by misuse ,The consequences are the responsibility of the person himself, and our company does not bear any responsibility. The company does not make any form of guarantee, including (but not limited to) the actual marketability and suitability guarantee for a specific purpose. The company is not responsible for the errors contained in this information, or for the occasional or indirect damage caused by the provision of this manual, actual performance and use. This user manual contains all...
Open the catalog to page 31.5m m,2.0mm,3.0mm,4.5mm for face treatment 6.0mm.9mm.l3mm for body treatment.
Open the catalog to page 4CARTRIDGE INSTALLATION © Remove the protective film on the cartridge, make suer there is dry and no any dirt at the interface of cartridge © Align the probe interface with the handle, and the protrusions on the probe correspond to the grooves of the handle © Gently insert the probe horizontally into the handle and heara click O When Changing or removing the cartridge. Press the safety lockon the side of the handle and gently pull outthe probe horizontally. 1. Current means Used shots of each cartridge. Remain means the remain shots ofthe cartridge 2. Type of cartridge 3.0nly display, not real
Open the catalog to page 55. Distance between points 7.Setting the limited shots for each treatment to alarm 8. Total used shots for the current treatment (including all the cartridges) lO.Start/ standy: status the machine ll.Repeat/Single:Repeat means the continuous shooting Single,mean only shoot one shot 12.Shot count information 13.Setting 1.Insert the handles to the machine and with the cartridge 3. Adjust the Energy length(4) ,the distance between points(5) and the Energy (9) 4. After adjusting the parameter,press the start/standy(10), Apply the get. then put the cartridge onto the skin tightly.and press the switch...
Open the catalog to page 6TREATMENT AREA Before & after
Open the catalog to page 7Before After
Open the catalog to page 82.To prevent unauthorized use of the equipment, ensure that it is only used by trained and certified personnel. To avoid possible injury during the nursing process, do not operate nearthe eyes of the patient Avoid caringfor the thyroid, thyroid cartilage and trachea. Avoid direct care of breast tissue and main bloodvessels. If there is any failure or adverse event, immediately stop the nursing program. Before taking care, remember to apply an appropriate amount of ultrasound gel in the care area. Before outputting energy, check whether the probe is correctly and completely attached to the skin....
Open the catalog to page 9•Diabetes orepilepsy •Severeskin disease • Stripping surgery or heart disease •Allergies or hyperplastic scars •Hemostatic dysfunction 2.4 System safety precautions • To avoid the risk of electric shock, be sure to check the probe, hand tools and power cord before use. • Do not use power cords or probes that have been damaged orare leaking liquid. • Do not remove the cover or hand tools of the main unit, because it is not allowed to modify the device. • Do not lean on the device, and do not cause physical external shocks to the device, as this may cause permanent system damage. • Do not use equipment...
Open the catalog to page 10© Duringthe operation, the experiencershould be constantly asked aboutthe comfort level and the adjustment of the energy level to ensure that the experiencer accepts the experience in a pleasant state; © Focus on strengthening treatment in the problem area (increasingenergy); Managers must regularly inspect the instruments and components. Whether the power socket is reliably connected to the ground. Please check whether the content of the prompt before using the instrument is correct, and stop using it if it is incorrect. Periodically clean the equipment to ensure the sanitation and good operation...
Open the catalog to page 11The quality problem host is guaranteed for one year free of charge (Note: The warranty is based on the purchase receipt and warranty card; the warranty scope here is limited to the instrument host, excluding accessories And other consumables that need to be replaced regularly). After the warranty period has expired, please contact the manufacturer directly to provide paid aftersales service.