SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT
12Pages

{{requestButtons}}

Catalog excerpts

SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT - 1

SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT 30.0020.300

Open the catalog to page 1
SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT - 2

All comments should be addressed to ChM sp. z o.o.  Lewickie 3b,16-061 Juchnowiec Kościelny, Poland tel. +48 85 713-13-30÷38, fax: +48 85 713-13-39 www.chm.eu  e-mail: chm@chm.eu Review date The manufacturer reserves the right to introduce design chang

Open the catalog to page 2
SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT - 3

2. TECHNICAL PARAMETERS AND EQUIPMENT 4 3.2. MOBILE STAND FOR TOURNIQUET CONTROL UNITS 5 5.1. CONNECTION TO THE NETWORK OF MEDICAL GASES 7 5.3. TOURNIQUET INFLATION AND DEFLATION. PRESSURE REGULATION IN TOURNIQUET 8 5.4. SETTING TOURNIQUET OCCLUSION TIME 9

Open the catalog to page 3
SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT - 4

EN Prior to first use, consult information on how to use the device 1. INDICATIONS FOR USE Single adjustable tourniquet control unit is intended to provide compressed air to tourniquets used to control blood flow in extremities in order to produce a bloodless surgical field. 2. TECHNICAL PARAMETERS AND EQUIPMENT Work factor Feed pressure Output pressure (in tourniquet) Time measurement The manufacturer reserves the right to introduce design changes. Equipment supplied with tourniquet control unit Name Tourniquet control unit air hose - blue cat. no. 30.0035.010 Compressed air spiral hose...

Open the catalog to page 4
SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT - 5

2 Single tourniquet for children 3 Single femoral tourniquet 4 Single femoral tourniquet 5 Single femoral tourniquet 6 Conical single femoral tourniquet 7 Single arm tourniquet long 9 Single tourniquet for babies The range of use Dimensions Cat. No (limb circumference in cm) 25-40 64x13 30.0009 Tourniquets are additional equipment of the control unit and are offered as separate devices. 3.2. MOBILE STAND FOR TOURNIQUET CONTROL UNITS The stand [30.0027.000] serves as a mobile platform for the tourniquet control unit. It is equipped with a stable base provided with rubber wheels, basket for...

Open the catalog to page 5
SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT - 6

EN Installation of the control unit on the stand Position the unit on the stand support (1) so that the threaded holes (2) in the unit base are in line with fixing screws (3) of the stand. Tighten the fixing screws in the base of the stand. 1 - Control panel 2 - Handle 3 - Medical compressed air 400kPa terminal 4 - Holes for mounting the unit on the mobile stand 30.0027.000 4

Open the catalog to page 6
SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT - 7

4 - Knob of pressure regulation 5 - Spiral hose terminal to connect the tourniquet 6 - Manometer of pressure measurements in tourniquet 7 - Timer 5. OPERATION 5.1. CONNECTION TO THE NETWORK OF MEDICAL GASES To use the device, it must be supplied with the medical compressed air of a pressure of 400kPa from the hospital medical gases network. Use compressed air spiral hose [30.0037] to connect the unit with a network of medical gases. NOTE: There are several standards of medical gases network connections (Table 1). Check the compliance of the quick coupling connector standard of the hose B...

Open the catalog to page 7
SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT - 8

EN NOTE: Keep the order of connections performed. NOTE: Quick coupling connector (B) may only be connected to the network of medical gases which is compressed air of 400kPa. Any attempt to connect the tourniquet control unit to the gas outlet other than medical compressed air of 400kPa may result in damage to the quick coupling connector and the device. When not in use, disconnect the unit from the compressed air network following the procedure opposite to the connection procedure. NOTE: The unit when connected to the compressed air network and is not supplying the tourniquet with air,...

Open the catalog to page 8
SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT - 9

EN 5.4. SETTING TOURNIQUET OCCLUSION TIME The tourniquet control unit has been equipped with a timer (7) which allows for controlling the tourniquet occlusion time. In order to set the time of occlusion, press MIN button to increase the number of minutes. Press SEC button to increase the number of seconds. Press START/STOP button to start the countdown. When the set time of occlusion has passed, sound signal is activated. NOTE: The countdown of the set time of occlusion does not start automatically upon inflating the tourniquet. To reset the timer settings, press simultaneously both MIN and...

Open the catalog to page 9
SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT - 10

It is recommended to carry out technical maintenance and calibration of the device at least once a year by the manufacturer, ChM company. 8. LIFETIME AND DISPOSAL The lifetime of the tourniquet control unit is assumed for 10 years. After this period, the product should be sent to the manufacturer in order to: determine the device further suitability for use, perform maintenance works, repairs or to recommend the user to purchase a new unit. 9. LABELS AND WARNINGS Nameplate SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT 30.0020.300 cat. no. serial no. SN:XXX work factor medical compressed air...

Open the catalog to page 10
SINGLE ADJUSTABLE TOURNIQUET CONTROL UNIT - 12

ChM sp. z o.o. Lewickie 3b 16-061 Juchnowiec Kościelny Poland tel. +48 85 713 13 20 fax +48 85 713 13 19 chm@chm.eu www.chm.eu