JC200D

JC200D

JC200D

Product catalog summary
Overview: The JC200D Focused Ultrasound Tumor Therapeutic System is designed for the non-invasive treatment of uterine fibroids, specifically in gynecology. It aims to minimize harm to patients by preserving the uterus and sexual function while avoiding damage to the pelvic floor structure.
Specifications: The system offers a non-invasive treatment option that does not require blood transfusions or radiation. It is a day treatment performed under conscious sedation without the need for anesthesia. The procedure is guided by real-time ultrasound with digital quantitative analysis.
Clinical Advantages: The treatment preserves the uterus and sexual function, ensuring no damage to the pelvic floor. It is a non-invasive procedure that avoids the risks associated with traditional surgical methods.
Clinical Cases: The document includes MRI images and case studies demonstrating the efficacy of the system. For example, a 50-year-old woman showed complete absorption of a submucosal uterine fibroid two years post-treatment. Another case involved a 28-year-old woman with secondary infertility, where successful treatment was observed.
Research and References: Studies cited include research on the safety and efficacy of US-guided high-intensity focused ultrasound for submucosal fibroids and outcomes of unintended pregnancies post-treatment.
End-users and Adoption: The system is used in over 100 centers worldwide, with more than 60,000 cases reported by November 2014. Notable institutions using the system include the European Institute of Oncology in Milan, The John Radcliffe Hospital in Oxford, and Queen Mary Hospital in Hong Kong, among others.
See more

Catalog excerpts

JC200D-1

Treatment—Minimize harm to patients CHONGQING HAIFU MEDICAL TECHNOLOGY CO., LTD Email: [email protected] Website: www.halfumedlcal.com Address: N0.1 Qingsong Road , Renhe, Yuebei District, Chongqing 401121, RR.China Focused Ultrasound Tumor Therapeutic System (for Gynaecology)

 Open the catalog to page 1
JC200D-2

Model Focused Ultrasound Tumor Therapeutic System (for Gynaecology)

 Open the catalog to page 2
JC200D-3

• An ultrasound beam can propagate through living tissue harmlessly and be focused at a tiny focal region. The energy in the focal region is high enough to induce an immediate thermal toxicity (temperature above 56 °C) which will cause irreversible coagulative necrosis (a "lesion" ). • From a point (single exposure) to a line, then a slice, then a volume that covers the entire tumor at any • Large-volume ablation in a single treatment • Safe ablation of malignant tumors adjacent to major blood vessels • 3D targeting module defines the boundary of tumor • 3D planning module divides tumors into...

 Open the catalog to page 3
JC200D-4

Clinical Cases Uterine fibroids MRI images of a 50-year-old woman received US- Clinical Advantages guided HIFU ablation of submucosal uterine fibroid. ● Non-invasive treatment , with no blood transfusion and no radiation The ablated fibroid was completely absorbed 2 years ● Preserve of uterus and sexual function, no damage to the structure of pelvic floor later. a: before treatment, b: 1week, c: 6 week, d:1 ● Day treatment under conscious sedation, with no anaesthesia year, e: 2 years after HIFU treatment. ● Real-time ultrasound guided therapy with digital quantitative analysis Wei Wang&Yang...

 Open the catalog to page 4
JC200D-5

Total Solution Professional Equipment With complete intellectual rights, it is the world first equipment clinically applied in tumor treatment, a result of over 20 years experience and optimization. Experienced Specialists A team of experienced medical and engineering specialists will provide integrated training and service to enable the end-users independent operation of Customized Solution Suitable clinical protocols, operation & management advices and research cooperation proposal will be tailored for each end-user.

 Open the catalog to page 5
JC200D-6

Installation Environment

 Open the catalog to page 6