1. Catalogs
  2. CIAT
  3. AIR ACCESS - NA0731D
video corpo

AIR ACCESS - NA0731D

AIR ACCESS - NA0731D
1 / 12 PagesView full catalog

AIR ACCESS - NA0731D

Product catalog summary
Overview: The document details the features and specifications of CIAT's Air Access range of air handling units (AHUs), designed to maintain air quality with a focus on accessibility and hygiene. The units are compliant with EN1886 (2007) standards and are suitable for various applications, including medical and clean room environments.
Specifications: The AHUs offer airflows from 1,000 to 30,000 m³/h (0.25 to 8.5 m³/s). They feature a self-supporting casing with 50 mm double skin panels insulated with rock wool for acoustic and thermal performance. The units are equipped with sliding doors for complete access, ensuring easy maintenance and air quality management.
Design and Accessibility: The patented sliding doors allow full access to filters, coils, and fans, facilitating maintenance. The multi-service bulkhead centralizes hydraulic and electrical connections, enhancing accessibility. The units are designed with smooth internal panels and stainless steel drain trays to minimize dust collection and ensure complete water removal.
Performance and Compliance: The AHUs meet various performance classes: air tightness (L2 standard, L1 optional), mechanical strength (D2), thermal insulation (T2), thermal bridge (TB2), and filter panel leak (F9). Acoustic efficiency is achieved through noise reduction panels, with transmission loss tested across different frequencies.
Options and Customization: The units can be customized with various options, including different filtration levels (G4 to H14), frequency inverters, plug fans, and heat wheels. External arrangements include a roof and air inlet weather louvre for protection.
Installation and Handling: The AHUs are designed for simple installation and commissioning, with features like threaded coil headers and optional supports for mounting. Handling is facilitated by transverse feet and a safety kit for sliding doors.
Manufacturing and Expertise: CIAT's manufacturing facilities adhere to ISO 9001 standards, offering a wide range of factory-fitted options and a technical selection software to optimize air handling needs based on priorities like price, sound level, and heat recovery.
See more

Catalog excerpts

AIR ACCESS - NA0731D-1

NA0731D_Air Access.qxd 06/04/2010 10:14 Page 1 Sustained air quality guaranteed NA 07.31 D u n i v e r s a l c o m f o r t Air 1 000 to 30 000 m3/h 0.25 to 8.5 m³/s handling unit

 Open the catalog to page 1
AIR ACCESS - NA0731D-2

The reassuring product design by an air handling unit specialist for Completely accessible via sliding doors CIAT remains loyal to its product design as you would expect from a leading air handling unit manufacturer, constructing AHUs to exceptional levels when assessed to EN1886 (2007) standard. Made of closed double skinned panels, the casing is painted outside (inside in option) as standard, maximising the smooth surfaces. The even white painted interior (which can be stainless steel) minimizes dust collection (medical range). Stainless steel fully sloping drain trays guarantee complete water...

 Open the catalog to page 2
AIR ACCESS - NA0731D-3

NA0731D_Air Access.qxd 06/04/2010 10:18 Page 3 1 000 to 30 000 m3/h 0.25 to 8.5 m³/s Multi-service bulkhead Allows the front access panels to be completely removed; all the hydraulic or electrical connections are centrally located within the upper multi-service bulkhead. • heat exchanger headers, • dial or tube manometer, • differential pressure switch, • external isolators, • lighting switches, • internal wiring. The multi-service bulkhead has total access from the top which facilitates the fitting and total or partial wiring of components. Total access for easy maintenance and for maintaining...

 Open the catalog to page 3
AIR ACCESS - NA0731D-4

Sliding doors CIAT is the first European manufacturer to design an AHU with a completely removable front thanks to its patented sliding doors. There are no fixed panels therefore allowing complete access to all components within the AHU. Allen key 1/4 turn locks Rollers below doors High grade casing for best performance Self-supporting casing. sliding doors (patented). Complies with the most stringent Filter panel leak - F9 50 mm double skin panels as standard Insulated with rock wool, the optimum for ACOUSTIC and THERMAL performance. External skin pre painted 2 colours. Internal skin with galvanised...

 Open the catalog to page 4
AIR ACCESS - NA0731D-5

NA0731D_Air Access.qxd 06/04/2010 10:21 Page 5 The AIR ACCESS range of air handling units includes the following standard features ● Sliding doors ● The multi-service bulkhead ● Easy access to the multi service bulkhead ● Smooth internal panels ● Stainless steel and sloping drain tray, completely and easily removable Tube manometer fitted at each filter stage ● ● Drain plug and air vent cap on each set of threaded headers ● Transverse support feet also used for lifting 9 sizes of air handling units for airflows from 0.25 to 8.5 m³/s / 1 000 to 30 000 m3/h (With 3 m/s air velocity on cooling coil)...

 Open the catalog to page 5
AIR ACCESS - NA0731D-6

Examples of components available Motorised - Damper Filtration equipped with manometers With droplet eliminator Smooth removable blanking plates to prevent headers Threaded headers with draining plug and airvent. Removable drain trays frame equipped with manometers Casing construction according to the EN 1886 standard • F9 or > F9 - Filter frame leakage External arrangement The external arrangement Air Access is equip- ped with a roof, an air inlet weather louvre. Elements from the multi-service bulkhead are protected by a wide roof overhang.

 Open the catalog to page 6
AIR ACCESS - NA0731D-7

Antifrost drawer with sensor Mounted on slide rails Air flow controller as option Frequency inverter Fitted with seal and anti- vibration pads Optional frequency inverter fitted on the motor. PLUG FAN fitted with tubular seal or flexible sleeve Plate heat exchanger Double deck arrangement Efficiencies available: from H2 to H4 HEAT WHEELS Double deck arrangement Efficiencies available: from H2 to H4

 Open the catalog to page 7
AIR ACCESS - NA0731D-8

NA0731D_Air Access.qxd 06/04/2010 10:26 Page 8 M E D I CA L The guarantee for maintaining air hygiene The reassuring product designed by an air handling unit specialist with the needs of health actors and clean room users in mind. - Complete access. - Smooth painted internal panels. - Clean external casing with multi-service bulkhead. - Many possibilities - Filtration from G4 to H14. - Easy maintenance.

 Open the catalog to page 8
AIR ACCESS - NA0731D-9

Selection example On air handling unit "Air Access 150 Industry" type Location: internal Position: horizontal Sliding panels for complete access Service Bulkhead for hydraulic and electrical Selection conditions: - Filter condition: part soiled SOUND POWER SPECTRUM (SWL) Breakout noise level TOTAL SOUND POWER LEVEL Breakout noise level Sound spectrum available for use frequency Air Access 150 Industry dimensions Software which optimises your CIAT benefits from a complete manufacturing facility, from marketing, design and development right through to production and control, all of which meet ISO...

 Open the catalog to page 9
AIR ACCESS - NA0731D-10

Simple installation and commissioning High level mounting Each section is equipped with 2 or 3 transverse feet to facilitate handling operations and to enable easy setting on a plinth or frame. When mounting at height, CIAT provides a safety kit to lock the sliding doors. The joining of sections has been simplified: fit the air seal, and then using four tightening devices adjust to form an air-tight seal. The tightening devices can be fitted internally or externally to the The drain tray pipe should be protected during handling operations. This facilitates the fitting of the siphon, the size...

 Open the catalog to page 10
AIR ACCESS - NA0731D-11

Air inlet and discharge connections AHU inlet and discharge dimensions Two-way mixing box inlet dimensions Fan discharge dimensions for different

 Open the catalog to page 11
AIR ACCESS - NA0731D-12

NA0731D_Air Access.qxd 06/04/2010 10:34 Page 12 CIAT, industrial expertise Each of our 8 high-tech manufacturing plants throughout the world benefits from 75 years of expertise in air handling. With such a significant production capacity at our disposal, we implement standardised manufacturing processes for a number of our products, including our ClimaCIAT concept air access air handling unit. Our significant logistics and storage capabilities, electronic order management system and fully automated production line enable us to offer competitive prices and delivery times for this range. CIAT,...

 Open the catalog to page 12

All CIAT catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.