Overview: The Aqualis 2 is a reversible heat pump designed for both heating and cooling applications, suitable for residential and small tertiary environments. It operates efficiently under various conditions and is environmentally friendly, using HFC R410A refrigerant.
Specifications: The heat pump operates under NF PAC conditions in accordance with the NF 414 standard. It supports chilled water temperatures of 7°C/12°C and hot water temperatures of 35°C/30°C. The sound pressure level is measured at 5 meters from the unit, 1.5 meters from the ground, in a free field with directivity 2.
Models and Capacities: The Aqualis 2 is available in several models with varying capacities. Heating capacities range from 6.2 kW to 19.4 kW, with corresponding power inputs from 1.8 kW to 4.9 kW. The Coefficient of Performance (COP) ranges from 3.5 to 4.1. Cooling capacities range from 5.3 kW to 17.5 kW, with power inputs from 2.0 kW to 6.4 kW.
Design and Features: The unit features a UV and corrosion-resistant casing and operates efficiently at outdoor temperatures as low as -15°C. It includes a Microconnect control unit with a backlit LCD, weekly programming, and data storage capabilities. The system is designed for easy integration with underfloor heating/cooling systems and fan coil units.
Environmental and Economic Benefits: Aqualis 2 is designed to be environmentally friendly, utilizing outside air to produce 70% of the required calories, thus reducing energy consumption. It offers significant cost savings by operating during off-peak times and using a non-polluting refrigerant fluid.
Additional Options: The system can be paired with a SANI 300L or PACSOL hot water tank to meet domestic hot water needs, providing hot water at a fraction of the cost of conventional systems.
See more

Catalog excerpts

NA0349N-1

AQUALIS 2 Heat Pump 35H 50H 20HT 28HT 35HT 50HT 65HT 75HT 8,1 2,2 3,6 10,4 3 3,5 13,2 3.2 4,1 6 1,7 3,5 7.9 2,1 3.7 10,2 2,7 3,8 13,8 3,5 3,9 17,2 4,3 4 19,4 4,9 4 - - - - - - 35T 50T 65T 75T kW kW L 5,3 2,0 7,1 2,7 5 8,5 3,7 13,7 4,0 8 5,1 2.6 7,0 2,5 5 8,5 3,4 11,8 4,4 14,7 5,0 8 17,5 6,4 Kpa 3 / 52 3 / 42 3 / 47 3 / 63 3/52 3/42 3 / 47 3 / 62 3 / 84 3 / 80 m /h dB(A) 1 44 3 1.4 1.7 2.3 47 51 51 230 V - 1 ph - 50Hz + T + N 1 44 1.4 1.7 2.3 2.8 47 51 51 53 400 V - 3 ph - 50Hz + T + N 2.5 53 O Aqualis 2 Cooling only Cooling capacity Power input Expansion vessel - contents Accelerator pump / nb of speeds / available pressure Air flow Sound level Supply voltage T 28H 6,2 1,8 3,5 R 20H kW kW F Aqualis 2 Reversible Heating capacity Power input COP O M operating conditions - NF PAC in accordance with the NF 414 standard Chilled water temperature 7°C/12°C Outside air 35°C Hot water temperature 35°C/30°C, outside air DB 7°C WB 6°C Sound pressure level : 5m from the unit, 1.5 from the ground, free field, directivity 2 Reversible heat pump Haute Température 35 1035 1035 35 A 0 L 657 1257 1750 mm C Evaporator temperature 7°C Condensor temperature 30/35°C 0 S 600mm Models mass kg empty in operation 135 120 156 145 158 140 RO NME N TA L LY F R IEN D LY VI V E 50 65 75 DHW option 300 L D E L'E N VI RO NN EM I IO N N CT ZA de Chautagne – 73310 Serrières en Chautagne - France [email protected] - www.ciat.com U O TE NA 03.49 N PR T HFC R410A EN 20 28 35 mass kg empty in operation 82 73 88 79 91 82 EN Models Models 50-65-75 R Models 20-28-35 Aqualis 2 A comprehensive system for heating and cooling

 Open the catalog to page 1
NA0349N-2

Aqualis 2's added benefits The Aqualis 2 heat pump from CIAT is the key element of a comprehensive heating and/or cooling system for housing and small tertiary comfort. All the hydraulic components needed for operation in one compact unit High energy efficiency (COP from 3.6 to 4.11) UV and corrosion-resistant casing with a sleek design Operates at outdoor temperatures as low as -15°C Aqualis 2 Heat pump A comprehensive system for heating and cooling Control unit Aqualis 2 supplies an underfloor heating/cooling system, fan coil type individual emitters or units concealed within a suspended ceiling...

 Open the catalog to page 2
NA0349N-3

Aqualis 2's added benefits The Aqualis 2 heat pump from CIAT is the key element of a comprehensive heating and/or cooling system for housing and small tertiary comfort. All the hydraulic components needed for operation in one compact unit High energy efficiency (COP from 3.6 to 4.11) UV and corrosion-resistant casing with a sleek design Operates at outdoor temperatures as low as -15°C Aqualis 2 Heat pump A comprehensive system for heating and cooling Control unit Aqualis 2 supplies an underfloor heating/cooling system, fan coil type individual emitters or units concealed within a suspended ceiling...

 Open the catalog to page 3
NA0349N-4

operating conditions - NF PAC in accordance with the NF 414 standard Chilled water temperature 7°C/12°C Outside air 35°C Hot water temperature 35°C/30°C, outside air DB 7°C WB 6°C Sound pressure level : 5m from the unit, 1.5 from the ground, free field, directivity 2 ZA de Chautagne - 73310 Serrières en Chautagne - Fra [email protected] - www.ciat.com

 Open the catalog to page 4

All CIAT catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.