video corpo

Model 002LFC
2Pages

{{requestButtons}}

Catalog excerpts

Model 002LFC - 1

IMRT Thorax Phantom Model 002LFC showing optional water equivalent rod with ion cavity COMPLETE QA FROM CT IMAGING TO DOSE VERIFICATION The CIRS Model 002LFC IMRT Thorax Phantom for film and ion chamber dosimetry is designed to address the complex issues surrounding commissioning and comparison of treatment planning systems and complete system QA from CT imaging to dose verification. The 002LFC is elliptical in shape and properly represents an average human torso in proportion, density and two-dimensional structure. It measures 30 cm long x 30 cm wide x 20 cm thick. The phantom is constructed of proprietary tissue equivalent epoxy materials. Linear attenuations of the simulated tissues are within 1% of actual attenuation for water and bone, and within 3% for lung from 50 keV to 15 MeV. Tissue equivalent interchangeable rod inserts accommodate ionization chambers allowing for point dose measurements in multiple planes within the phantom. Hole placement allows verification in the most critical areas of the chest. One half of the phantom is divided into 12 sections, each 1 cm thick, to support radiographic or GafChromic® film. Additional inserts are available to support a variety of other detectors including TLD’s, MOSFET, and diodes. Handling, assembly and proper orientation of the phantom is easy with the use of a unique alignment base and holding device. The surfaces of the phantom are marked for ease of laser alignment. CT markers are included to ensure accurate film to plan registration on the center film.* • Verify heterogeneity corrections • Correlate CTU to electron density • Check dose distributions in sensitive areas • Check depth doses and absolute dose • Calibrate film with ion chamber & other detectors* The CIRS line of IMRT phantoms is compatible with the RIT 113 software for film to plan analysis. GafChromic® is a registered trademark of International Specialty Products, Wayne, NJ. 1 900 Asbury Ave • Norfolk, Virginia 23513 • USA Tel: 800.617.1177 • 757.855.2765 • Fax: 757.857.0523 WWW.CIRSINC.COM Tissue Simulation

Open the catalog to page 1
Model 002LFC - 2

IMRT THORAX PHANTOM IMRT VERIFICATION SYSTEM CIRS IMRT phantoms are manufactured from tissue equivalent materials that mimic within 1% from 50 keV to 15 MeV for accurate simulation during all necessary steps of IMRT verification. The interchangeable rod design allows the phantom to accommodate many dose measurement devices such as ion chambers, TLD, diodes and MOSFET’s in the same location within the phantom. Phantom cross sections accommodate GafChromic® or standard ready-pack films. Side View Front View 1 cm Section Front View 15 cm Section SPECIFICATIONS OVERALL DIMENSIONS: Phantom Body:...

Open the catalog to page 2

All CIRS catalogs and technical brochures

  1. UltraiQ

    2 Pages

  2. Model 711-HN

    2 Pages

  3. Model 701-706

    16 Pages

  4. Model 602

    2 Pages

  5. Model 004

    16 Pages