Model 062M, 062MA, 062MQA

Model 062M, 062MA, 062MQA
1 / 16 PagesView full catalog

Model 062M, 062MA, 062MQA

Product catalog summary
Overview
The CBCT Electron Density & Image Quality Phantom System is designed to enhance imaging quality and treatment outcomes in radiotherapy. It integrates three phantoms into one package, allowing configurations as Model 062M, 062MA, 062QA-35, and 062MQA, which can be used individually or combined for various imaging needs.
Model Configurations
  • Model 062M: Includes head and body electron density sections with tissue-equivalent plugs for CT number to electron density calibration.
  • Model 062MA: An extended version for Cone Beam CT systems, facilitating reliable CT calibration curves for treatment plan adaptation.
  • Model 062MQA: Combines the 062MA with the 062QA-35 Image Quality Phantom for comprehensive image quality assurance tests.
Capabilities
The system supports tests per AAPM TG-1 and TG-142, dose verification with ionization chambers, and evaluation of beam hardening effects on HU values and image quality. It accommodates ion chambers for dose measurements and heterogeneity corrections.
Specifications
  • Model 062M: Evaluates CT scan data, corrects for inhomogeneities, and simulates tissue within diagnostic and therapeutic energy ranges using nested disks made from Plastic Water®-LR.
  • Model 062MA: Designed for Cone Beam CT systems, includes additional materials for off-central axis measurements and supports ion chamber accommodation for dose measurements.
  • Model 062QA-35: Composed of layers for uniformity, CT number linearity/slice thickness, low contrast/magnification, and spatial resolution, assessing various image quality indicators.
Components and Materials
The phantoms are made of water and tissue-equivalent epoxy resins, with interchangeable slabs for repositioning. They include electron density plugs for different tissues, such as lung, breast, bone, liver, muscle, and adipose tissue.
Image Quality Phantom Features
The Image Quality Phantom evaluates uniformity, CT number linearity, slice thickness, low contrast, magnification, and spatial resolution, using various materials and configurations to simulate clinical imaging conditions and assess system performance over time.
Conclusion
The CBCT Electron Density & Image Quality Phantom System is a comprehensive tool for improving imaging quality and treatment planning in radiotherapy, offering flexibility and precision in electron density calibration and image quality assessment.
Additional Features
  • Conducts all CT Image QA tests as per AAPM TG Report #1.
  • Facilitates dose measurements using ionization chambers.
  • Calibrates electron density in multi-slice CT and CBCT.
  • Allows central axis and off-set measurements.
  • Positions simulated tissue materials at 17 locations within CT & CBCT energy ranges.
  • Optimized for volumetric imaging with quick positioning and customizable configurations.
Positioning Options
  • Customizable setups for off-axis dosimetry and electron density measurements.
  • Modular system allows "in-air" and "on-the-couch" configurations for minimal interference.
Warranty
Standard products have a warranty period ranging from 3 to 60 months, depending on the product type.
Contact Information
Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA. Technical assistance is available via toll-free number.
See more

Catalog excerpts

Model 062M, 062MA, 062MQA-1

CBCT Electron Density & Image Quality Phantom System Model 062M, 062MA & 062MQA MINIMIZE DOSE • INCREASE IMAGE QUALITY • ENHANCE OUTCOMES PRODUCT GUIDE 2428 Almeda Avenue Suite 316 • Norfolk, Virginia 23513 • USA Tel: 800.617.1177 • 757.855.2765 • Fax: 757.857.0523 WWW.CIRSINC.COM Tissue Simulation & Phantom Technology

 Open the catalog to page 1
Model 062M, 062MA, 062MQA-3

Overview The CBCT Electron Density & Image Quality Phantom System integrates three phantoms in one highly functional and ergonomic package. The phantom system can be configured as: CAPABILITIES • Perform tests per AAPM TG-1 and TG-142 • Obtain maximum CTU information from a single scan • Calibrate with optional high-density references • Perform dose verification with ionization chambers • Evaluate effects of beam hardening on HU values & Image quality • Accommodate ion chambers for dose measurements and validation of heterogeneity corrections Model 062M Electron Density Phantom Model 062MA CBCT...

 Open the catalog to page 3
Model 062M, 062MA, 062MQA-4

Standard System Components Electron Density Phantom Head Insert Electron Density Phantom Body w/feet CBCT Electron Density Phantom 062MA-37 Annulus Insert (100 mm thick) CBCT Electron Density Phantom 062MA-34 Bolus Section (37.5 mm thick) Electron Density Phantom Plugs CBCT Electron Density Phantom 062MA-36 Annulus (100 mm thick) CBCT Electron Density Phantom 062MA-33 Bolus Section (12.5 mm thick) CBCT Electron Density Phantom 062MA-24 Bolus Section (50 mm thick) ION Chamber Insert Background Insert CBCT Image Quality Phantom CBCT Image Quality Phantom 062MQA-30 Holder & Stand

 Open the catalog to page 4
Model 062M, 062MA, 062MQA-5

CBCT ELECTRON DENSITY AND IMAGE QUALITY PHANTOM ELECTRON DENSITY PHANTOM CBCT ELECTRON DENSITY PHANTOM IMAGE QUALITY PHANTOM Model 062M Model 062MA Model 062QA-35

 Open the catalog to page 5
Model 062M, 062MA, 062MQA-6

Electron Density Phantom MODEL 062M The Electron Density Phantom, Model 062M, is used to account for tissue heterogeneity in radiotherapy treatment planning. The phantom is used with a CT scanner to provide precise correlation between electron density of tissues and their CT number in Houndsfield units (HU). The Model 062M consists of two nested disks made from Plastic Water®-LR. They can represent both head and abdomen configurations. Nine different tissue equivalent electron density plugs can be positioned at 17 different locations within the scan field. Included is a water vial plug that can...

 Open the catalog to page 6
Model 062M, 062MA, 062MQA-7

CBCT Electron Density Phantom MODEL 062MA The Cone Beam (CBCT) Electron Density Phantom is an extended version of the CIRS Model 062M Electron Density Phantom, specifically designed for Cone Beam CT Imaging systems. Preliminary data shows that there may be differences between the HU readings for Diagnostic CT and Cone Beam CT. The geometry of the Cone Beam CT requires additional material and suggests that off-central axis measurements should be taken. The phantom is a valuable tool for CT number to electron density calibration in volumetric imaging. Reliable CT calibration curves help enable...

 Open the catalog to page 7
Model 062M, 062MA, 062MQA-8

CBCT Image Quality Phantom MODEL 062QA-35 The purpose of image quality measurements is to quantify various image quality indicators for 3D images taken from a selection of image acquisition and reconstruction settings representative of clinical practices. Assessment of the image quality parameters over time can show trends in variation of said parameters helping the user to decide whether or not recalibrations of the imaging system are necessary. The Image Quality Phantom (062MQA-50) is composed of four layers: Uniformity, CT number Linearity/Slice Thickness, Low Contrast/Magnification, ans Spatial...

 Open the catalog to page 8
Model 062M, 062MA, 062MQA-9

SPATIAL RESOLUTION LAYER The Low Contrast Layer assesses the system's ability to detect small differences in contrast. It contains three sets of low contrast rods with linear attenuation differences of 0.5%, 1% and 2% relative to the background material. The diameters of the low contrast rods were chosen so as to provide a 0.5 ratio between two adjacent rods by cross section and volume. The Spatial Resolution Layer is designed to evaluate the spatial resolution of IGRT systems. Line pair patterns from 1 lp/cm to 16 lp/cm are embedded in the background. In order to minimize artifacts, each line...

 Open the catalog to page 9
Model 062M, 062MA, 062MQA-10

CBCT Electron Density & Image Quality Phantom MODEL 062MQA The Model 062MQA phantom provides a comprehensive tool that can be used for both electron density calibration and image quality assessment of Cone Beam CT systems integrated in radiation therapy devices. The electron calibration function of the phantom enhances the outcome of adaptive radiation therapy while the image quality features address the fine balance between optimizing image quality and minimizing radiation dose. The 062MQA CBCT Electron Density & Image Quality Phantom incorporates 3 phantoms: 1. Electron Density Phantom (50...

 Open the catalog to page 10
Model 062M, 062MA, 062MQA-11

Optional Accessories MODEL 062M, 062MA & O62MQA TABLE 5 PART NO. ELECTRON DENSITY, x 1023 electrons/cc 800 mg/cc HA in Water Equivalent - Core Insert Titanium Rod Core Insert Distance Marker Insert Water Equivalent Insert 1000 mg/cc HA in Water Equivalent - Core Insert 1250 mg/cc HA in Water Equivalent - Core Insert ICRU Cortical Bone Equivalent Core Insert*** 1500 mg/cc HA in Water Equivalent - Core Insert 1750 mg/cc HA in Water Equivalent - Core Insert Solid Dense Bone (1000 mg/cc HA) Equivalent Electron Density Plug Solid Dense Bone (1500 mg/cc HA) Equivalent Electron Density Plug Solid Dense...

 Open the catalog to page 11
Model 062M, 062MA, 062MQA-12

Positioning Options CBCT ELECTRON DENSITY & IMAGE QUALITY PHANTOM SYSTEM SETUPS The CBCT Electron Density & Image Quality Phantom System allows users to customize the phantom setup according to their specific testing needs. Images below show different positioning arrangements of sections, which allow for off-axis Dosimetry measurements, Electron Density off-axis measurements, and axial positioning of each layer of the CBCT Image Quality Phantom (062MQA-50). The illustrations below demonstate configurations with the 062MQA-50 inside the bolus (additional cofigurations shown on pages 14 and 15)....

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.