MRI Distortion Phantom for SRS
2Pages

{{requestButtons}}

Catalog excerpts

MRI Distortion Phantom for SRS - 1

MRI Distortion Phantom for SRS Model 603A FOR ASSESSMENT OF IMAGE DISTORTION IN TREATMENT PLANNING SYSTEMS CIRS Model 603A was designed for assessment of MR image distortion in Stereotactic Radiosurgery Planning. It is also a useful tool for verifying image fusion and deformable image registration algorithms used in various treatment planning systems. The tissue equivalent, anthropomorphic design provides the closest conditions to a clinical imaging scenario. The phantom can be imaged using X-ray, Computed Tomography and Magnetic Resonance. It images well with all MRI sequences tested to date, including T1 weighted, T2 weighted, 3D Time of Flight, MPRAGE and CISS. The skull is manufactured from a plastic-based bone substitute, and the interstitial and surrounding soft tissues are made from a proprietary signal generating water-based polymer. The entire phantom is encased in a clear plastic shell to protect gel from desiccation. The phantom is supplied with specially designed pads that allow fixation with any stereotactic frame or mounting for end-to-end testing. The phantom is also suitable for frameless SRS QA. The entire inter-cranial portion of the skull volume is filled with an orthogonal 3D grid of 3mm diameter rods spaced 15 mm apart. Five extended axis-rods intersect at the reference origin of the grid. The end of each extended axis is fitted with CT/MR markers allowing for accurate positioning with lasers and co-registration of CT and MR image sets. The phantom includes right and left air voids, 3 mm in diameter by 17 mm long to simulate each ear canal for evaluation of potential distortions commonly found in clinical settings. To accommodate image fusion techniques, CIRS can offer value-added options and services such as phantom specific CMM, reference CT or MRI data sets, attachment of customer specific registration devices and inclusion of special point markers. Features • Provides a realistic anthropomorphic scenario for CT and MR imaging • Unique inter-cranial 3D grid design allows assessment of spatial distortion • Special pads enable use with all fixation frames • CT/MR markers facilitate positioning and image regist ration 2428 Almeda Avenue Suite 316 • Norfolk, Virginia 23513 • USA Tel: 800.617.1177 • 757.855.2765 • Fax: 757.857.0523 WWW.CIRSINC.COM Tissue Simulation & Phant

Open the catalog to page 1
MRI Distortion Phantom for SRS - 2

3D ANTHROPOMORPHIC SKULL PHANTOM MODEL 603A INCLUDES OVERALL DIMENSIONS COMPONENT DESCRIPTION 3D Anthropomorphic Skull Phantom Skull: Plastic-based bone substitute Interstitial/ Soft tissues: Water-base Stereotactic Frame Pads Custom Carry Case User Guide SRS Frame Support Cups (set of 4) Grid: Reinforced nylon OPTIONAL FEATURES MODEL 035 COMPONENT DESCRIPTION CT DICOM Data Set (Serial number specific, 1.5 mm slice thickness @ 120 kvp) Model 603A in Stereotactic Frame (not included) 2014 Computerized Imaging Reference Systems, Inc. All rights reserved. Specifications subject to change...

Open the catalog to page 2

All CIRS catalogs and technical brochures

  1. Model 002LFC

    2 Pages

  2. UltraiQ

    2 Pages

  3. Model 711-HN

    2 Pages

  4. Model 701-706

    16 Pages

  5. Model 602

    2 Pages

  6. Model 004

    16 Pages