Catalog excerpts

Triple Modality 3D Abdominal Phantom Model 057A CT/ ULTRASOUND/ MRI IMAGE FUSION• LIVE SCANNING• BIOPSY TRAINING The CIRS Triple Modality 3D Abdominal Phantom is constructed of a self-healing formulation of Zerdine®(1) that allows multiple biopsy insertions with minimal needle tracking, and is ideal for demonstrating image-guided navigation technologies. Abdominal imaging is useful for diagnosing disease and monitoring treatments. The Model 057A is representative of a small adult abdomen and can be imaged under CT, MR and ultrasound. This feature makes the phantom a useful tool for applications such as image fusion studies; imaging protocol developments; scan technique training; and system testing, validation and demonstration. The Model 057A simulates the abdomen from approximately the thorax vertebrae (T9/T10) to the lumbar vertebrae (L2/L3) using simplified anthropomorphic geometry. The materials provide contrast between the structures under CT, MR and ultrasound. The solid polymer background gel will not leak when punctured.* Internal structures include the liver, the portal vein, two partial kidneys, a partial lung, the abdominal aorta, the vena cava, a simulated spine and six ribs. The liver has six lesions and the kidneys each have one lesion. A muscle layer and outside fat layer surround these structures and plastic end caps make the phantom durable enough for extended scanning. Blood vessels have CT contrast added to provide enhanced auto registration in image fusion applications The phantom includes a foam lined hard carry case. To accommodate image fusion techniques, CIRS can offer value-added options and services such as phantom specific CMM, reference CT or MRI data sets, attachment of customer specific registration devices and inclusion of special point markers. • Demonstrate CT, ultrasound and MRI scan techniques • Assess image-fusion algorithms • Optimize imaging protocols • Improve performance of freehand abdominal biopsies US Patent #5196343 *NOTE: Some permanent tracking may be evident if debris and air bubbles are entrained in the gel during the biopsy procedure. To extend the lifetime of the phantom, the use of higher gauge needles that have been wetted and de-aired prior to insertion is recommended. 2428 Almeda Avenue Suite 316 • Norfolk, Virginia 23513 • USA Tel: 800.617.1177 • 757.855.2765 • Fax: 757.857.0523 WWW.CIRSINC.COM Tissue Simulation
Open the catalog to page 1
TRIPLE MODALITY 3D ABDOMINAL PHANTOM SPECIFICATIONS DIMENSIONS MODEL 057A INCLUDES COMPONENT DESCRIPTION Triple Modality 3D Abdominal Phantom User Guide Outer Fat Layer: Z-SkinTM MATERIALS PHANTOM WEIGHT Hard Tissue: Epoxy Resin Lungs: Urethane Other Soft Tissue: Zerdine® gel INTERNAL ORGANS • (1) Liver with six lesions • (2) Kidneys with one lesion each OPTIONAL FEATURES MODEL 057A-035 COMPONENT DESCRIPTION CT DICOM Data Set (Serial number specific, 1.5 mm slice thickness @ 120 kvp) • (1) Spine • (1) Partial lung • (1) Portal Vein • (1) Vena Cava • (1) Aorta • (6) Ribs • Surrounding Soft...
Open the catalog to page 2All CIRS catalogs and technical brochures
-
Model 002LFC
2 Pages
-
Breast Elastography Phantom
2 Pages
-
Prostate Training Phantom
2 Pages
-
MRI-LINAC Dynamic Phantom
8 Pages
-
UltraiQ
2 Pages
-
E2E SBRT Phantom
8 Pages
-
Model 711-HN
2 Pages
-
Model 701-706
16 Pages
-
Model 062M, 062MA, 062MQA
16 Pages
-
Model 602
2 Pages
-
Model 004
16 Pages