Steam Sterilizers - 1

Steriliser HIGH TEMPERATURE STEAM AUTOCLAVE FOR HOSPITAL APPLICATION

Open the catalog to page 1
Steam Sterilizers - 2

Cisa Group Cisa Group is a global supplier of infection control systems with production plants in Italy and Brazil. Founded in 1947, Cisa Group, together with Cisa America and Cisa Brasile, forms an international group that is one of the world’s leading manufacturers of washing, disinfection and sterilization technology for infection control for the healthcare and life sciences industries. HEALTHCARE INDUSTRY LIFE SCIENCES INDUSTRY Creating safer environments in hospitals, healthcare facilities and laboratory applications is a fundamental priority for the well-being of humans worldwide....

Open the catalog to page 2
Steam Sterilizers - 3

Technology TEX TEXT Healthcare Cisa Group develops advanced infection control technologies for the safeguard of healthcare workers and the health of patients. Complete central sterilizing service departments for hospitals (CSSD) Sterilization for healthcare applications and clinics of all sizes Disinfection and washing technologies for different operational requirements Cisa Group is the technology partner for scientists, researchers and engineers who develop life-enhancing products every day. Life Science Washing and sterilization technologies for laboratories and research centres...

Open the catalog to page 3
Steam Sterilizers - 4

High temperature steam steriliser Cisa’s technology ensures high quality equipment for hospital applications and patient safety, with optimum results at low running costs. Within the CSSD Central Sterilizing Service Department comprises that service within the hospital in which medical/surgical supplies and equipment, both sterile and non-sterile, are cleaned, prepared, processed, stored, and issued for patient care. Cisa’s High Temperature Steam Steriliser is installed, following CSSD regulations, inside the clean area (as shown in the caption), with pass-through access to the sterile...

Open the catalog to page 4
Steam Sterilizers - 5

Why use a Cisa hospital steam steriliser The machine is designed with PLC industrial grade microprocessor control for higher safety and guaranteed reliability; Cisa’s R&D engineers have used advanced design to optimize the machine for hospital use by working, on quality, safety and ergonomy. The machine is built with the highest quality components for perfect hygiene, perfect operation, high durability and maximum safety. Stainless steel of the highest quality is used for assembling the machine. The machine frame and front panels are manufactured using stainless steel 304. The hydraulic...

Open the catalog to page 5
Steam Sterilizers - 6

Steam Steam Generator The standard equipment features a steam generator is manufactured in stainless steel AISI 316L with powerful heating elements, stainless steel water pump and optional break tanks. The steam generator is equipped with auto draining system for high reliability and better functionality in its lifetime. The machine can be configured for steam generation using one of the following solutions: • (E): Built-in steam generator with electric heating • (V): External steam supply from hospital steam network (domestic steam). • (EV): Combination between (E) & (V) which enables the...

Open the catalog to page 6
Steam Sterilizers - 7

Door(s) safety closure & interlock safety The machine can be manufactured with a single door (1P) or pass-through double doors (2P). The machine is provided with high safety features for the door(s), including the following: • Both doors (in case of double doors execution) cannot open at the same time, as the interlock safety device prevents cross contamination • The safety lock does not enable door opening if a cycle is running or if the chamber is pressurized • There is no cycle start or steam inlet until the door(s) have been checked and are tightly closed • For operator safety: door...

Open the catalog to page 7
Steam Sterilizers - 8

User interface The touch screen allows to control the following functions: • Selecting cycle and packing type • Self-check display before starting the cycle and confirmation of the selected page • Display of status cycle and parameters (temperature, pressure and time) • Pages for set-point cycle follow up and real time diagram display • Audio/visual alarms display with alarm history • F0 Calculation • Visualization of the last 80 cycles- graphical or value parameters • Possibility of downloading the cycles on an external USB drive for storage and PC visualization • Maintenance program for...

Open the catalog to page 8
Steam Sterilizers - 9

Alarms Audio and visual alarms are defined for operator warning; the alarms list includes multilevel alarms with clear message notifications; alarm levels are configured, according to the level of importance, to stop the machine or the cycle, or to issue a warning notification without affecting the running cycle. The alarm lists are complete for safe and perfect operation for the operators and the machines. The alarms history can display all the alarms that occurred in the last 90 days. Alarms are also displayed on the unloading side in case of double doors models. The end of cycle alert is...

Open the catalog to page 9
Steam Sterilizers - 10

Advantages Pre-vacuum phase This phase is characterised by use of alternating Vacuum/Steam pulsations, which guarantees a good steam penetration inside the load. The type and the quantity of pulsations depend on the chosen cycle. Sterilisation phase (plateau) This is the main phase of the process in which steam is maintained inside the chamber at a constant temperature and pressure, depending on the selected cycle. Post-vacuum phase Cisa technology is uses a powerful vacuum pump that has high vacuum values with less time needed for drying which is one of the most important issues in terms...

Open the catalog to page 10
Steam Sterilizers - 11

Energy saving system The Cisa sterilisers are designed to reach a high level of energy saving, using optimized power and energy conservation at the same time, without affecting the performance of the cycle, and with full respect for the environment; they also use different solutions for thermal, noise, drainage and air outlets protection as well as low electromagnetic emissions. Excellent insulation The pressure vessel is covered with high-thickness material for insulation, which prevents heat loss. The perfect insulation increases the quality of the sterilisation cycle, reducing potential...