The document discusses the benefits of using the Ultra-Pro II™ Needle Guidance System for ultrasound-guided puncture procedures. It emphasizes the importance of needle guidance in improving accuracy, efficiency, and patient care.

Key Benefits
  • Accuracy and Efficiency: Needle guidance increases accuracy and efficiency, especially for novice users, by limiting needle motion within the scan plane and ensuring complete needle tip visibility.
  • Reduced Procedure Time and Trauma: The system decreases needle manipulation, leading to shorter procedure times and less tissue trauma, thereby minimizing complication rates and patient morbidity.

Product Features
  • Compatibility: Ultra-Pro II™ is compatible with all leading ultrasound manufacturers.
  • Improved Clinical Outcomes: Enhances needle visualization, procedure efficiency, patient throughput, and success rates.
  • Reduced Variability: Reduces technique variability, learning curve, procedure time, and needle motion.

Usage Instructions
  1. Attach Bracket: Align and attach the reusable non-sterile bracket to the transducer.
  2. Gauge Selection: Select and alter gauge sizes easily with the guide's large funnel, accepting sizes 8.5FR and 14-23GA.
  3. Place Guide Insert: Slide the insert into the needle guide for a fixed path according to on-screen guidelines.
  4. Quick-Release: Use the large tab for easy detachment of the needle from the transducer.
  5. Cover Up: Use the civ-Flex™ cover to reduce infection rates and expand the sterile field.
  6. Attach Guide: Secure the needle guide onto the bracket using proper sterile technique.

Ordering Information
Contact CIVCO customer service for orders or product samples. International distribution details are available on their website.

Contact Details
See more

Catalog excerpts

Ultra-Pro II? In-Plane Needle Guidance - Product Brochure-1

Safe. Efficient. Guiding Patient Care.

 Open the catalog to page 1
Ultra-Pro II? In-Plane Needle Guidance - Product Brochure-2

Reasons to make ultrasound needle guidance the standard of care in your facility: 1 2 Ultra-Pro II ™ is compatibile with all leading ultrasound manufacturers. Using needle guidance during ultrasound-guided puncture procedures increases accuracy and improves efficiency, particularly for the novice user. The guide limits needle motion within the scan plane as the needle advances toward the target, ensuring complete needle tip visibility from start to finish. The decreased needle manipulation afforded by the needle guide results in shorter procedure times and less tissue trauma — minimizing complication...

 Open the catalog to page 2
Ultra-Pro II? In-Plane Needle Guidance - Product Brochure-3

Ultra-Pro II™ Needle Guidance System Providing clinical confidence in tissue biopsy, fluid aspiration and catheter placement • Needle visualization • Technique variability • Procedure efficiency • Learning curve • Patient throughput • Procedure time • Success rates • Needle motion CIVCO’s needle guidance systems are designed to correspond with on-screen software guidelines. Scan to see Ultra-Pro II in action! Visit WWW.CIVCO.COM to learn more about Ultra-Pro II and CIVCO’s complete line of needle guidance solutions!

 Open the catalog to page 3
Ultra-Pro II? In-Plane Needle Guidance - Product Brochure-4

For ordering information, call 319.2 Attach Bracket Attach custom reusable non-sterile bracket to transducer by aligning locating features. Six steps for clinical confiden Gauge Selection Easy-to-read gauge sizes on the inserts make it simple to identify and alter gauge sizes. The guide features a large funnel for instrument insertion and accepts sizes 8.5FR and 14-23GA (19GA not available).

 Open the catalog to page 4
Ultra-Pro II? In-Plane Needle Guidance - Product Brochure-5

Cover Up The telescopically-folded CIV-Flex™ cover makes it easy to reduce infection rates and cross-contamination. Expand your sterile field up to 58" by covering the transducer and cord with the sterile latex-free cover. Attach Guide Use proper sterile technique to attach the needle guide onto the bracket and lock into place with a single click. iding Patient Care. Place Guide Insert After selecting the appropriate gauge size, the insert slides easily into the needle guide and is ready for use — providing a fixed path that directs instruments according to on-screen guidelines. Quick-Release...

 Open the catalog to page 5
Ultra-Pro II? In-Plane Needle Guidance - Product Brochure-6

Safe. Efficient. Guiding Patient Care. Contact a CIVCO customer service specialist to place an order or request a product sample. For international distribution, visit CIVCO Worldwide at WWW.CIVCO.COM. Toll-free within the U.S. and Canada: 800.445.6741 Toll-free Facsimile: 877.329.2482 Direct Dial: 319.248.6757 Facsimile: 319.248.6660 Email: [email protected] WWW.CIVCO.COM COPYRIGHT © 2012. CIVCO IS A REGISTEREDTRADEMARK OF CIVCO MEDICAL SOLUTIONS. CIV-FLEX AND ULTRA-PRO II ARETRADEMARKS OF CIVCO. ALL OTHERTRADEMARKS ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS. ALL PRODUCTS MAY NOT BE LICENSED IN...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.