video corpo

ANALYTICAL EN
20Pages

{{requestButtons}}

Catalog excerpts

ANALYTICAL EN - 3

WIDE RANGING ANALYTICAL APPLICATIONS Our Analytical line is the result of 40 years of gas generator production experience; it consists of hydrogen, air and gas purifier generators, accompanied by a complete series of accessories and add-on components. The acquired know-how over the years means we can respond with specific solutions to every analytical application: gas chromatography, LC-MS, TOC, ICP, Sample Preparation, ELSD, Thermo Analysis and more. Analytical line’s strong point is in the modular structure, made up of independent modules, that have the same features: freely modular with...

Open the catalog to page 3
ANALYTICAL EN - 4

ANAL YTICAL CLAIND GAS GENERATOR Whether talking about nitrogen, hydrogen or pure air, Claind offers a practical, economical alternative to pressurized gas cylinders and creating distribution lines. eliminate your present delivery, management and rental costs, with an efficient budgetary management that lets you see payback fast, as well as keeping operating costs low. the wide range consists of reliable, easy-to-use generators, guaranteed long life span and low maintenance costs. claind generators increase your company’s safety, producing all the gas you need only when you need it,...

Open the catalog to page 4
ANALYTICAL EN - 5

NITROGEN, ZERO AIR AND HYDROGEN PRODUCTION Claind solutions for producing nitrogen self-production use PSA (Pressure Swing Adsorption) technology. The PSA system consists of two beds of CMS (Carbon Molecular Sieve), alternatively pressurized and depressurized. Each bed can consist of one or more columns. Compressed air, which has been pre-treated to eliminate dust and humidity, enters the base of the first active bed and flows through the CMS. Oxygen, carbon dioxide and other polluting substances in the air are trapped, but the nitrogen moves through the bed and exits at the top of the...

Open the catalog to page 5
ANALYTICAL EN - 6

ANAL YTICAL Claind has developed a catalytic reactor specifically for air filtration that is ideal for eliminating impurities. As a matter of fact, the Platinum Palladium HC system, found in most purifiers, allows the hydrocarbons (HCT < 0.1 ppm) to be completely removed at low catalysis temperatures for a stable, noise-free base line. The technology Claind uses for electrolysis is: PEM with solid electrolyte: the most recent technology which is normally used in generators for lab applications that require the purest hydrogen; multi-layer electrodes: prior to PEM but very stable and less...

Open the catalog to page 6
ANALYTICAL EN - 7

hydrdben rs opposed to helium Helium has always been used and considered as the main choice for an analytical carrier gas. However, helium’s current natural resources are running out and such large demand is no longer possible. As a matter of fact, many labs have been having more frequent problems finding it. Suppliers can no longer provide helium in sufficient time and for reasonable costs. Using hydrogen instead of helium is less well-known but its advantages are consistent: MORE ECONOMICAL, EASY TO FIND, CAN BE USED AT LOWER TEMPERATURES, GREATER COLUMN DURATION, FASTER SEPARATION, LESS...

Open the catalog to page 7
ANALYTICAL EN - 8

CHOOSE THE RIGHT PRODUCT FOR YOUR APPLICATIONS GAS CHROMATOGRAPHY The natural configuration for gas chromatography is the “tower”: four generators (hydrogen, nitrogen, zero air and compressor) are stacked one on top of the other, allowing a reduction in displacement. The generators can also be used individually as independent modules or combined in 2 or 3 module versions. a available in three models for 200-400-600 Nml/min flows with > 99.9999% purity a designed for Carrier Gas in GC, GC-MSD and “FAST GC” a Safety system with acoustic alarms, screen messages and automatic production...

Open the catalog to page 8
ANALYTICAL EN - 9

a available in basic and HC version so the HYDROCARBONS CAN BE COMPLETELY REMOVED USING THE PT/PD CATALYZER a Capable of distributing 500Nml/min with > 99.9995% purity a Capable of supporting up to 12 make up FID/ NPD, up to 7 ECD or 5 S/S a ready to be connected to the dedicated airComp compressor a parallel connection up to 4 stackable tower configuration generators a CPU with touch Screen display, which can be linked to the generators with CAN-BUS, allows monitoring of the operating status and menu reading with the maintenance status, the ALARM report AND functional pARAMETERs a Capable...

Open the catalog to page 9
ANALYTICAL EN - 10

ANAL YTICAL a Capable of distributing 3000Nml/min a Comes with a PSA dryer and Pt/Pd catalytic reactor a Platinum Palladium HC system to completely remove the hydrocarbons (HCT < 0.1 ppm) a Excellent for NPD and FID for an absolutely stable, noise-free base line a Adapted to support up to 8 FID a Ready to be connected to the dedicated AirComp compressor a Parallel connection up to 4 stackable tower configuration generators a CPU with Touch Screen Display, which can be linked to the generators with CAN-BUS, allows monitoring of the operating status and menu reading with the maintenance...

Open the catalog to page 10
ANALYTICAL EN - 11

lcms The LC-MS analyzers on the market now often require functional parameters (type, capacity, gas pressure and purity) dissimilar to each other. In order to respond to these requirements, Claind has developed specific solutions capable of facing any commercial analyzer model, thereby eliminating any incompatibility issue between the analyzer and the nitrogen generator. a available in 2 models: - the NiGen LCMS 40-1 model from 40 Nl/min with compressor - the NiGen LCMS 100 model from 100 Nl/min without compressor a Capable of supplying up to 4 LC-MS analyzers a the NiGen LCMS 40-1 equipped...

Open the catalog to page 11
ANALYTICAL EN - 12

NITRO 35 AND 70 a available in 2 models with different capacities: - Nitro 35 model with capacity up to 35 Nl/min - Nitro 70 model with capacity up to 70 Nl/min a 24 liter internal tank that lengthens the stand-by periods a purity up to 99.99% (H20 < - 55°C Dew Point and HCT < 0.01 ppm) a membrane keyboard for making fast, easy commands a equipped with full turn wheels to facilitate moving

Open the catalog to page 12
ANALYTICAL EN - 13

toc Determining carbon in liquids, muds and solids requires air with a high degree of purity. a Capable of providing 1500 Nml/min, with hydrocarbon removal < 0.1 ppm and carbon dioxide < 1 ppm a platinum Palladium HC system to completely remove the HCT for an absolutely stable, noise-free base line a high efficiency end filter to remove residual CO2 a ready to be connected to the dedicated airComp compressor a possible parallel connection up to 4 stackable tower configuration generators a CPU with touch Screen display that can be linked to the generators with CAN-BUS, allowing monitoring of...

Open the catalog to page 13

All Claind catalogs and technical brochures

  1. LASER CUT

    4 Pages

  2. TIVANO

    4 Pages

  3. N2 MAXI

    4 Pages

  4. N2 PICO

    4 Pages

  5. N2 FLO

    4 Pages

  6. NIGEN GC

    4 Pages

  7. IND EN

    16 Pages

  8. FOOD EN

    16 Pages