1. Catalogs
  2. Clarius Mobile Health
  3. Manufacturer Disclosure Statement for Medical Device Security

Manufacturer Disclosure Statement for Medical Device Security

Manufacturer Disclosure Statement for Medical Device Security
1 / 11 PagesView full catalog

Manufacturer Disclosure Statement for Medical Device Security

Product catalog summary
Manufacturer Information
Clarius Mobile Health manufactures the Clarius Ultrasound App, which is used on mobile devices to acquire ultrasound images. Contact support is available via [email protected].
Device Description and Use
The app operates on iOS or Android devices to capture ultrasound images from the Clarius scanner. It allows patient information to be added and stored in the Clarius Cloud or a customer's PACS.
Security and Data Management
The app handles personally identifiable information (PII), which can be displayed, transmitted, stored, and modified. PII is stored in both volatile and non-volatile memory and can be configured for automatic deletion. It can be imported/exported and transmitted over wireless networks.
Audit and Authorization
The device uses standard OS logs for auditing and requires user login to prevent unauthorized access. Users can have different privilege levels based on roles.
Cyber Security and Updates
Security updates are necessary, with instructions provided for patch installation, though remote installation is not supported.
Data Integrity and Backup
The device lacks integral data backup capabilities and emergency access features. There are no data integrity checking mechanisms for stored health data.
Anti-Malware Capabilities
The device does not support anti-malware software, and only manufacturer-authorized personnel can repair systems when malware is detected.
Node Authentication
Node authentication is supported using certificate-based network connection authentication, but internal firewalls are not supported.
Connectivity Capabilities
The device supports Wi-Fi and Bluetooth connectivity but not LTE or Ethernet. It supports API calls and Transport Layer Security (TLS), though TLS is not configurable.
Person Authentication
Unique IDs and passwords are enforced, with support for password changes and complexity rules. Multi-factor authentication and biometric controls are not supported.
Physical Locks
The device includes provisions for securing components that maintain PII.
Third-Party Components
A secure software development process is followed, but there is no web page for software support dates and updates.
Software Bill of Materials (SBoM)
The SBoM is not available, and there is no process to generate a list of software components installed on the device.
System and Application Hardening
Software integrity checking mechanisms are employed, but the owner/operator cannot perform these checks independently.
Security Guidance
Security documentation is provided, but instructions for permanent data deletion are not included.
Health Data Storage Confidentiality
Data encryption capabilities are noted, but specific configurations and instructions are not provided.
Transmission Confidentiality and Integrity
PII is encrypted before transmission, with mechanisms to ensure data integrity during transmission.
Remote Service
Remote service connections for device analysis or repair are not permitted.
Upgrade and Maintenance
The app can be upgraded via mobile device app stores, with users responsible for maintaining upgrades. Auto-update configurations are available.
Security and Anti-malware
The app relies on the host mobile device for anti-malware capabilities, with no known restrictions affecting regular use.
Communication and Access
The app communicates with Clarius Scanners via a wireless access point, with user credentials managed through Clarius Cloud.
Data Protection
Clarius relies on iOS and Android app sandboxing for storing Protected Health Information (PHI), recommending encryption and advising against using rooted devices.
See more

Catalog excerpts

Manufacturer Disclosure Statement for Medical Device Security-1

Clarius Mobile Health Clarius Ultrasound App 51-10-00002Question ID DOC-1 Question Manufacturer Name Device Description Device Model Manufacturer Contact Information See note Clarius Mobile Health Clarius Ultrasound Scanner Intended use of device in network-connected environment: Document Release Date Coordinated Vulnerability Disclosure: Does the manufacturer have a vulnerability disclosure program for this device? ISAO: Is the manufacturer part of an Information Sharing and Analysis Organization? Diagram: Is a network or data flow diagram available that indicates connections to other system components or expected external resources? SaMD: Is the device Software as a Medical Device (i.e. software-only, no hardware)? Does the SaMD contain an operating system? Does the SaMD rely on an owner/operator provided operating system? Is the SaMD hosted by the manufacturer? Is the SaMD hosted by the customer? The Clarius Ultrasound App runs on a user provided mobile device (iOS or Android based). The App acquires ultrasound images from the Clarius scanner. Patient information can be added to the App. Once an examination is complete, patient information and images can be uploaded to the Clarius Cloud or to a customer's PACS where they may be stored permanently. MANAGEMENT OF PERSONALLY IDENTIFIABLE INFORMATION Can this device display, transmit, store, or modify personally identifiable information (e.g. electronic Protected Health Information (ePHI))? Does the device maintain personally identifiable information? Does the device maintain personally identifiable information temporarily in volatile memory (i.e., until cleared by power-off or reset)? Does the device store personally identifiable information persistently on internal media? Is personally identifiable information preserved in the device's non-volatile memory until explicitly erased? Does the device store personally identifiable information in a database? Does the device allow configuration to automatically delete local personally identifiable information after it is stored to a long term solution? Does the device import/export personally identifiable information with other systems (e.g., a wearable monitoring device might export personally identifiable information to a server)? Does the device maintain personally identifiable information when powered off, or during power service interruptions? Does the device allow the internal media to be removed by a service technician (e.g., for separate destruction or customer retention)?

 Open the catalog to page 1
Manufacturer Disclosure Statement for Medical Device Security-2

Clarius Mobile Health Clarius Ultrasound App Does the device allow personally identifiable information records be stored in a separate location from the device's operating system (i.e. secondary internal drive, alternate drive partition, or remote storage location)? N/A Does the device have mechanisms used for the transmitting, importing/exporting of personally identifiable information? Yes Does the device display personally identifiable information (e.g., video display, etc.)? Yes Does the device generate hardcopy reports or images containing personally identifiable information? Yes Does the...

 Open the catalog to page 2
Manufacturer Disclosure Statement for Medical Device Security-3

Clarius Mobile Health Clarius Ultrasound App AUDT-2.8.1 Remote or on-site support? N/A Application Programming Interface (API) and similar AUDT-2.8.2 activity? N/A AUDT-2.10 Other events (e.g., software updates)? N/A AUDT-2.11 Is the audit capability documented in more detail? N/A Can the owner/operator define or select which events are AUDT-3 recorded in the audit log? No Is a list of data attributes that are captured in the audit log for an event available? Does the audit log record date/time? Can date and time be synchronized by Network Time Protocol (NTP) or equivalent time source? Can audit...

 Open the catalog to page 3
Manufacturer Disclosure Statement for Medical Device Security-4

Clarius Mobile Health Clarius Ultrasound App

 Open the catalog to page 4
Manufacturer Disclosure Statement for Medical Device Security-5

Clarius Mobile Health Clarius Ultrasound App HEALTH DATA DE-IDENTIFICATION (DIDT) The ability of the device to directly remove information that allows identification of a person. Does the device provide an integral capability to de-DIDT-1 identify personally identifiable information? Yes Does the device support de-identification profiles that DIDT-1.1 comply with the DICOM standard for de-identification? No DATA BACKUP AND DISASTER RECOVERY (DTBK) The ability to recover after damage or destruction of device data, hardware, software, or site configuration information. Does the device maintain...

 Open the catalog to page 5
Manufacturer Disclosure Statement for Medical Device Security-6

Clarius Mobile Health Clarius Ultrasound App Does the device have anti-malware software available as Does the device documentation allow the owner/operator to install or update anti-malware Can the device owner/operator independently (re-MLDP-2.4 )configure anti-malware settings? N/A Does notification of malware detection occur in the MLDP-2.5 device user interface? N/A Can only manufacturer-authorized persons repair MLDP-2.6 systems when malware has been detected? N/A MLDP-2.7 Are malware notifications written to a log? N/A Are there any restrictions on anti-malware (e.g., MLDP-2.8 purchase,...

 Open the catalog to page 6
Manufacturer Disclosure Statement for Medical Device Security-7

Clarius Mobile Health Clarius Ultrasound App Can the device communicate with other systems external to the customer environment (e.g., a service host)? Yes See Note 3 Does the device make or recei ve API calls? Yes See Note 3 Does the device require an internet connection for its Does the device support Transport Layer Security (TLS)? Yes _ Does the device provide operator control functionality from a separate device (e.g., telemedicine)? No _ PERSON AUTHENTICATION (PAUT) The ability to configure the device to authenticate users. Does the device support and enforce unique IDs and passwords for...

 Open the catalog to page 7
Manufacturer Disclosure Statement for Medical Device Security-8

Clarius Mobile Health Clarius Ultrasound App Manufacturer's plans for security support of third-party components within the device's life cycle. Was a secure software development process, such as ISO/IEC 27034 or IEC 62304, followed during product development? Yes Does the manufacturer evaluate third-party applications and software components included in the device for secure development practices? Yes Does the manufacturer maintain a web page or other source of information on software support dates and updates? No Does the manufacturer have a plan for managing third-party component end-of-life?...

 Open the catalog to page 8

All Clarius Mobile Health catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.