CAP-575

CAP-575

CAP-575

Product catalog summary
Overview
The Series 575 Vertical Flow Modular Softwall Cleanroom is designed for cost-effective particulate control within a softwalled enclosure. It features a 2 x 4 ft. tubular steel NEST TIGHT ceiling grid system, allowing large spans without center posts, ensuring durability and ease of assembly. The cleanroom is available in various sizes and shapes, operating as either positive or negative pressure enclosures.
Specifications
The cleanroom is free-standing, requiring only the building floor for support. It includes a NEST TIGHT ceiling grid system for a leak-free ceiling, essential for optimal performance. The system includes gasketed HEPA filters, SEAL TIGHT cleanroom lights, and vinyl-covered blank ceiling panels. Additional HEPA filters can be added for future upgrades.
Features
  • 2 x 4 ft. tubular steel frame with 4 x 4 ft. angle iron legs
  • Large open spans up to 32 ft. without center supports
  • Room Class 100,000 to Class 10
  • Fast delivery and easy installation
  • Sturdy, durable softwall environment
Installation and Assembly
The cleanroom system is lightweight and prefabricated, requiring no on-site fitting or cutting. Assembly is straightforward, with components bolting, snapping, or setting into place. Prefabricated wiring reduces on-site costs and speeds up installation, with a single-point power connection.
Options and Customization
Options include ULPA filters, flow-thru lights, different curtain materials, and custom designs. Additional features like casters, gowning rooms, and prefab wiring kits can be added for enhanced functionality.
Guarantee
A written one-year warranty is provided with each softwall cleanroom.
Specifications
  • Standard sizes range from 2 ft. to 24 ft. in various configurations, with specific dimensions provided for each size.
  • Custom sizes are available upon request.
  • Outside dimensions are provided, with inside dimensions being 5 inches less than the outside.
Procedures and Recommendations
  • A clearance of 7 inches above the unit is recommended for proper servicing of filters and lights.
  • Consult the factory for spans up to 24 ft. and for specific details regarding seismic units, which require custom quotes and may alter dimensions.
Height Specifications
  • Standard inside and overall heights are provided for units ranging from 8 ft. to 10 ft., with specific heights for filters and lights.
  • Flow-through lights add an additional 5 inches to the height.
See more

Catalog excerpts

CAP-575-1

Series 575 Vertical Flow Modular Softwall Cleanroom Vertical Flow Modular Softwall Cleanroom The Series 575 softwall cleanroom is a cost-effective method of providing quality particulate control in a softwalled enclosure. The 2 x 4 ft. tubular steel NEST TIGHT ceiling grid system allows the cleanroom to enclose a large span without center posts. This system provides a durable, cost-effective, easy-toassemble cleanroom system. A variety of sizes and shapes are available to ensure a system that is matched to your individual needs. The softwall cleanrooms are free-standing and require only the building floor to support the NEST TIGHT ceiling grid system, HEPA filters, and cleanroom lights. This tubular frame is held in place by steel support legs to ensure a strong rigid structure. The entire frame and leg support system is finished with a white cleanroom-grade baked enamel paint. The NEST TIGHT ceiling grid is used to maintain a leak-free ceiling system. The NEST TIGHT grid system utilizes a special gasketed, overlapped and interlocking nested tee bar joint. This eliminates the butt joint space of conventional non-cleanroom tee bar grid systems. The proven NEST TIGHT ceiling grid system eliminates one of the largest problems in a cleanroom — a leaking ceiling grid system. Gasketed Series 112 HEPA filters, SEAL TIGHT cleanroom lights, and vinylcovered blank ceiling panels complete the ceiling grid system. These gasketed components along with the NEST TIGHT ceiling grid system provide a zero-leak cleanroom ceiling which is essential for optimum cleanroom performance. Features 2 x 4 ft. tubular steel frame with 4 x 4 ft. angle iron legs Large open spans up to 32 ft. with no center supports NEST TIGHT ceiling grid system maintains a leak-free ceiling system Complete with motorized ceiling HEPA filters, lights, ceiling panel, tee bars and prefab wiring — requires only assembly and singlepoint power connection Sturdy, durable softwall cleanroom environment Fast delivery and easy installation Room Class 100,000 to Class 10 For more information or to download or fax this product from the web, simply go to: www.cleanairproducts.com/57

 Open the catalog to page 1
CAP-575-2

Series 575 Vertical Flow Modular Softwall Cleanroom Overview The Series 575 softwall cleanroom is available from Class 100,000 to Class 10. They typically operate as positive pressure enclosures but can also be used as negative pressure containment areas to HEPA filter outgoing room air. The NEST TIGHT ceiling grid is used to maintain a leak-free ceiling system. The NEST TIGHT grid system utilizes a special gasketed, overlapped and interlocking nested tee bar joint. This eliminates the butt joint space of conventional non-cleanroom tee bar grid systems. The proven NEST TIGHT ceiling grid system...

 Open the catalog to page 2
CAP-575-3

Series 575 Vertical Flow Modular Softwall Cleanroom Strip Doors The strip door consists of (8) 8-in. wide strips with 2 in. overlap on each side along the length. This makes the standard strip door dimension 48 in. wide x 84 in. long x 80 mil thick. The strip doors are shipped assembled, with mounting angle on top. Optional material: • Heavy 125 mil clear vinyl strips for high-traffic areas • Clear anti-static vinyl • Clear flame-retardant anti-static vinyl • Yellow standard vinyl • Yellow flame retardant vinyl NOTE: Special “extra length” strip doors are available for all of the above materials....

 Open the catalog to page 3
CAP-575-4

Series 575 Vertical Flow Modular Softwall Cleanroom Basic Components of the Prefab Wiring Kit The basic components included with your prefab wiring kit are as follows: • Metal “plug together” male/female connectors and “plug together” flex metal cable segments • Electrical junction box • Lights and ON/OFF light switch • Speed control Connections The “plug together” system consists of “Reloc” brand metal connectors and “Reloc” brand metal flex cables. The “plug together” system provides connection between the ceiling lights, filter units, and junction box, and is UL listed. Electrical Junction...

 Open the catalog to page 4
CAP-575-5

Series 575 Vertical Flow Modular Softwall Cleanroom Standard Sizes Length Inside Overall Height Height (in.) (in.) 10 ft. 120 134 H0 = maximum height of filters and lights. Flow thru lights add 5 in. to height. 24 ft. x 48 ft. 617 271 Custom sizes available upon request. Consult factory for spans up to 24 ft. Outside dimension shown. Inside = Outside - 5 Recommended to have 7 in. clearance above unit to properly service filters and light. Consult factory for details. Seismic units available but must be specifically quoted to meet specific seismic conditions. This will change the overall dimensions....

 Open the catalog to page 5

All Clean Air Products catalogs and technical brochures

  1. CAP-301

    5  Pages

  2. CAP-109BL

    3  Pages

  3. CAP-112

    2  Pages

  4. CAP-116

    4  Pages

  5. CAP-901

    2  Pages

  6. CAP-130

    5  Pages

  7. CAP-1532

    5  Pages

  8. CAP701

    8  Pages

  9. CAP-591

    6  Pages

  10. CAP-558

    3  Pages

  11. CAP-560

    3  Pages

  12. CAP-582

    2  Pages

  13. cap-550

    4  Pages

  14. cap-556

    3  Pages

  15. CAP-577

    5  Pages

  16. CAP1414

    5  Pages

  17. CAP1421

    2  Pages

  18. CAP1412

    2  Pages

  19. CAP-18

    2  Pages

  20. CAP701KD-ST

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.