chemiLITE
4Pages

{{requestButtons}}

Catalog excerpts

chemiLITE - 1

chem i L I T Delivering simplicity and sensitivity through a dedicated chemiluminescence imaging system

Open the catalog to page 1
chemiLITE - 2

chem i L I T Western blot imaging has never been so easy - great Westerns without film The chemiLITE system allows the capture of chemiluminescence signals to detect target proteins on Western blots with sensitivity comparable or better than films SMALL FOOTPRINT Compact size takes up minimal bench space, allowing more room for experiments HIGH QUANTUM EFFICIENCY (QE) CAMERA Detects faintest bands AUTOMATED CHEMILUMINESCENT CAPTURE Perfect exposure without film COOLED CAMERA No annoying background noise on blots FIXED LENS CONTROLLED BY GENEPIX SOFTWARE One click to image any manufacturer’s...

Open the catalog to page 2
chemiLITE - 3

(ADVANCED LENS] The F/0.95 fixed focus lens gives optimum image quality ( HIGH QUANTUM EFFICIENCY CAME~RA) The 4-megapixel resolution CCD camera is very sensitive to low level light emissions, producing images of up to 16m pixels, allowing visibility and separation of faint, close bands on blots up to 11cm x 8cm. The chemiLITE camera has double the dynamic range of film and with a quantum efficiency of greater than 73% @ 425nm provides outstanding sensitivity for chemiluminescence imaging [SUPER LOW COOLING] Peltier cooling with exceptional signal to noise performance allows long exposure...

Open the catalog to page 3
chemiLITE - 4

genePIX acquisition software can be set up for single auto- T chem i L IGO IMAGING LOAD AND capture, series capture or manual capture of Westerns to generate a choice of one or a series of timed images. BRIGHTER WESTERNS When low light chemiluminescence Westerns are being imaged, the binning feature can be used to reduce exposure times. Binning combines pixels into larger formats to produce a super pixel which collects more light, increasing sensitivity or speeding up image capture time. A Western blot of diluted transferrin was prepared on a PVDF membrane. The membrane was treated with...

Open the catalog to page 4

All Cleaver Scientific catalogs and technical brochures

  1. Agarose

    2 Pages

  2. chemiPRO

    6 Pages

  3. cleanVIEW

    2 Pages

  4. clearVIEW

    2 Pages

  5. DGGE

    2 Pages

  6. DNAladders

    2 Pages

  7. eduPAC

    1 Pages

  8. gelTips

    1 Pages

  9. GTC96

    2 Pages

  10. HotStir

    2 Pages

  11. IdentiTapes

    1 Pages

  12. IEF

    2 Pages

  13. LargeForm

    2 Pages

  14. microDOC

    2 Pages

  15. miniMAX

    1 Pages

  16. miniONE

    2 Pages

  17. multiSPIN

    4 Pages

  18. multiSUB

    4 Pages

  19. nanoPAC

    2 Pages

  20. omniDOC

    2 Pages

  21. omniPAGE

    4 Pages

  22. omniPette

    4 Pages

  23. powerPRO

    2 Pages

  24. quickSPIN17

    1 Pages

  25. runSAFE

    2 Pages

  26. runVIEW

    4 Pages

  27. safeVIEW

    2 Pages

  28. Accessories

    1 Pages

  29. Glove Boxes

    1 Pages