Catalog excerpts
chem i L I T Delivering simplicity and sensitivity through a dedicated chemiluminescence imaging system
Open the catalog to page 1chem i L I T Western blot imaging has never been so easy - great Westerns without film The chemiLITE system allows the capture of chemiluminescence signals to detect target proteins on Western blots with sensitivity comparable or better than films SMALL FOOTPRINT Compact size takes up minimal bench space, allowing more room for experiments HIGH QUANTUM EFFICIENCY (QE) CAMERA Detects faintest bands AUTOMATED CHEMILUMINESCENT CAPTURE Perfect exposure without film COOLED CAMERA No annoying background noise on blots FIXED LENS CONTROLLED BY GENEPIX SOFTWARE One click to image any manufacturer’s...
Open the catalog to page 2(ADVANCED LENS] The F/0.95 fixed focus lens gives optimum image quality ( HIGH QUANTUM EFFICIENCY CAME~RA) The 4-megapixel resolution CCD camera is very sensitive to low level light emissions, producing images of up to 16m pixels, allowing visibility and separation of faint, close bands on blots up to 11cm x 8cm. The chemiLITE camera has double the dynamic range of film and with a quantum efficiency of greater than 73% @ 425nm provides outstanding sensitivity for chemiluminescence imaging [SUPER LOW COOLING] Peltier cooling with exceptional signal to noise performance allows long exposure...
Open the catalog to page 3genePIX acquisition software can be set up for single auto- T chem i L IGO IMAGING LOAD AND capture, series capture or manual capture of Westerns to generate a choice of one or a series of timed images. BRIGHTER WESTERNS When low light chemiluminescence Westerns are being imaged, the binning feature can be used to reduce exposure times. Binning combines pixels into larger formats to produce a super pixel which collects more light, increasing sensitivity or speeding up image capture time. A Western blot of diluted transferrin was prepared on a PVDF membrane. The membrane was treated with...
Open the catalog to page 4All Cleaver Scientific catalogs and technical brochures
-
2018 Cleaver Catalogue
88 Pages
-
Agarose
2 Pages
-
chemiPRO
6 Pages
-
cleanVIEW
2 Pages
-
clearVIEW
2 Pages
-
DGGE
2 Pages
-
DNAladders
2 Pages
-
eduPAC
1 Pages
-
gelTips
1 Pages
-
GTC96
2 Pages
-
HotStir
2 Pages
-
IdentiTapes
1 Pages
-
IEF
2 Pages
-
LargeForm
2 Pages
-
microDOC
2 Pages
-
miniMAX
1 Pages
-
miniONE
2 Pages
-
multiSPIN
4 Pages
-
multiSUB
4 Pages
-
nanoPAC
2 Pages
-
omniDOC
2 Pages
-
omniPAGE
4 Pages
-
omniPette
4 Pages
-
powerPRO
2 Pages
-
proteinLadders
2 Pages
-
quickSPIN17
1 Pages
-
runSAFE
2 Pages
-
runVIEW
4 Pages
-
safeVIEW
2 Pages
-
safeVIEWMINI2
2 Pages
-
Accessories
1 Pages
-
HORIZONTAL GEL SYSTEMS
2 Pages
-
proSETCatlogue2016
48 Pages
-
Clinical Electrophoresis
1 Pages
-
Glove Boxes
1 Pages
-
Cleaver Scientific Catalogue
79 Pages