ClivetPACK FFA - 1

CSRT-XHE-FFA  CSRN-XHE-FFA Packaged air-conditioning unit CSRT-XHE-FFA: cooling only CSRN-XHE-FFA: reversible heat pump Air cooled Roof Top Capacity from 69 to 83 kW ClivetPACK FFA The autonomous air-conditioners of the CSRT-XHE-FFA / CSRN-XHE-FFA series are Roof-top type units developed by Clivet using the most recent and advanced technologies available on the market dedicated to the treatment of air. Destined to the air-conditioning of all those environments that need full fresh air-conditioning that feature suction hoods such as kitchens, laboratories, projection rooms, etc.. Versatility of use: the wide range of versions, options and accessories allow unique integration and flexibility of choice, regardless of the intended use. During winter it is able to condition with full fresh air just through electrical supply up to -12°C and below such temperature air-conditioning is possible via pre-heating with a hot water or gas module coil. Easy to position and install: the units are exceptionally compact, perfect for positioning on particularly crowded roofs. The units, pretested in the factory, feature immediate start-up thanks to the packaged approach, which includes everything the systems needs. It only requires to be connected to the electrical mains and the air system. Electronic wall-mounting room thermostat pAD Main functions: - unit on/off - manual or automatic summer/ winter switching - temperature set-point modification humidity set-point modification - unit main information Reduced management costs: thanks to the high efficiency of the innovative refrigeration circuit optimized for the functioning at partial load, of free-cooling, of the standard heat recoverer on all models featuring air exhaust, of optional electrostatic air filters, of the automatic control and adjustment of all air flows drastically reduce the energy consumption and therefore the management costs. AIR Cooling only (CSRT-XHE-FFA) Heat pump (CSRN-XHE-FFA) Outdoor installation Hermetic Scroll Thermodynamic recovery EC Electronically commutated Plug Fan Electronic expansion valve dimensions and clearances Size – CSRT-XHE-FFA A - Length B - Width C - Height A2 B1 B2 CBFFA Operating weight CCFFA Operating weight Size – CSRN-XHE-FFA A - Length B - Width C - Height A2 B1 B2 CBFFA Operating weight CCFFA Operating weight The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations, refer to the relative Technical Bulletin. CAUTION! trouble-free operation of the unit it is essential to maintain the safety CBFFA Configuration for fresh air inlet For distances indicated by the green areas. CCFFA Configuration for fresh air inlet with outlet

Open the catalog to page 1
ClivetPACK FFA - 2

> CBFFA Configuration for fresh air inlet (Standard) > CCFFA Configuration for fresh air inlet with outlet > - Gas burner: not reguired (Standard) POWER CONTROL: > ADP ADAPTIVE + (capacity modulation) technical data ID Outdoor air temperature: 35°C D.B./24°C W.B; EER referred only to compressor; 12) SCROLL = scroll compressor Available nett pressure to overcome the supply (8; CCFFA; Configuration for outdoor air supply with exhaust and extraction (9; Net external static pressure at the exhaust side with the air flow given condition. The available ESP increases with reduced airflow. The...

Open the catalog to page 2

All CLIVET catalogs and technical brochures

  1. ELFORoom2

    4 Pages

  2. AQX

    2 Pages

  3. MDE-SL3

    2 Pages

  4. SCREWLine²

    2 Pages

  5. SPINchiller

    2 Pages

  6. SPINSAVER

    2 Pages