Overview: The document provides technical specifications and features of the WDAT-SL2 liquid chiller, which is designed for high efficiency and environmental sustainability. It is suitable for both civil and industrial applications requiring high performance and low maintenance costs.
Specifications: The WDAT-SL2 is an air-cooled, outdoor installation water chiller with a capacity range from 436 to 1439 kW. It uses R-134a refrigerant and is equipped with semi-hermetic twin-screw compressors. The unit is recognized for its high efficiency at both partial and full loads, classified as a class A unit by Eurovent.
Features: Key features include an economizer circuit, electronic expansion valves, tube bundle evaporator, and electronic control fans. The unit allows for ongoing capacity adjustment, ensuring precise control of chilled water temperature across a wide operating range.
Dimensions and Clearances: The document specifies the dimensions and clearances required for the unit's installation, emphasizing the importance of maintaining safety distances for trouble-free operation.
Acoustic Configurations: The chiller is available in various acoustic configurations, including standard, soundproofed, low noise, and super-silenced options.
Energy Recovery and Free-Cooling Options: The unit offers options for partial and total energy recovery, as well as direct free-cooling capabilities.
Technical Data: The document includes detailed technical data such as cooling capacity, power input, EER, ESEER, number of refrigeration circuits, and compressor types. It also provides sound pressure levels under specific conditions.
Accessories and Configurations: A range of accessories is available, including hydropacks, condenser coils, antivibration mounts, energy meters, remote control options, and various communication modules. The document advises consulting the Technical Bulletin for compatibility details.
Notes: The data is subject to change by the manufacturer without notice, and the document refers to standards and regulations for measurement and certification.
See more

Catalog excerpts

SCREWLine²-1

Water chiller Air cooled Outdoor installation Capacity from 436 to 1439 kW WDAT-SL2 is a liquid chiller fitted with screw compressors with R-134a refrigerant. The EXCELLENCE ST/SC version stands out for its extremely high efficiency levels both with operation at partial and full loads, which makes it a class A unit based on Eurovent’s efficiency rating and allows for considerable savings on running costs while preserving the environment. This is possible thanks to the economizer circuit on the compressors, the electronic expansion valves, the tube bundle evaporator and the electronic control fans supplied as standard. Moreover, the ongoing capacity adjustment allows for a quick adjustment of the system’s load and therefore an accurate control of the chilled water temperature with a wide operating range. Therefore WDAT-SL2 is the ideal solution for all civil and industrial applications that require high performance levels, operating continuity and lower running and maintenance costs. Unit listed on www.eurovent-certification.com Outdoor installation Semi-hermetic Twin-screw HYDRO PACK Electronic expansion valve Size – WDAT-SL2 ST-EXC A - Length ST-EXC B - Width ST-EXC C - Height ST-EXC A1 ST-EXC A2 ST-EXC B1 ST-EXC B2 SC-EXC A - Length SC-EXC B - Width SC-EXC C - Height SC-EXC A1 SC-EXC A2 SC-EXC B1 SC-EXC B2 ST-EXC Operating weight SC-EXC Operating weight LN-EXC Operating weight EN-EXC Operating weight The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations, refer to the relative Technical Bulletin. CAUTION! trouble-free operation of the unit it is essential to maintain the safety For ST-EXC Standard (ST)-Excellence distances indicated by the green areas. SC-EXC Compressors soundproofing (SC)-Excellence LN-EXC Low noise (LN)-Excellence EN-EXC Super-silenced (EN)-Excellence

 Open the catalog to page 1
SCREWLine²-2

versions and configurations LOW TEMPERATURE: Low temperature: not required (Standard) B Water low temperature FREE-COOLING: FREE-COOLING: not required (Standard) FCD Direct FREE-COOLING ACOUSTIC CONFIGURATION: Standard acoustic configuration (Standard) SC Acoustic configuration with compressor soundproofing LN Low noise acoustic configuration EN Extremely low noise acoustic configuration ST Excellence (Standard) ENERGY RECOVERY: Energy recovery: not required (Standard) D Partial energy recovery R Total energy recovery technical data Size – WDAT-SL2 Eurovent ST/SC-EXC Cooling capacity (EN14511:2013)...