CNAP® Monitor

CNAP® Monitor

CNAP® Monitor

Product catalog summary
Introduction
The document discusses the CNAP® system, a next-generation noninvasive monitoring technology for continuous blood pressure and hemodynamic control. It emphasizes ease of use, accuracy, reliability, and cost-effectiveness.

Key Features
  • Continuous Monitoring: Provides continuous noninvasive blood pressure (Sys, Dia, MAP, Pulse) and hemodynamic parameters (CO, CI, SV, SI, SVR, SVRI).
  • Accuracy and Reliability: Comparable to invasive clinical standards, suitable for patients with volatile blood pressure and during Goal Directed Therapy.
  • Cost-Effectiveness: Up to 77% cost savings with reusable CNAP® double finger sensor.
  • Convenience: Easy setup with immediate availability of blood pressure waveform and values.

Clinical Benefits
  • Goal Directed Therapy: Reduces postoperative infections, organ complications, and transfusions.
  • Fluid Responsiveness: CNAP® PPV/SVV accurately predicts fluid responsiveness in anesthetized patients.
  • Noninvasive Cardiac Output: Performs comparably to invasive methods.

Technical Specifications
  • Measuring Range: Sys: 40-250 mmHg, Dia: 30-210 mmHg, Pulse rate: 30-200 bpm.
  • Hemodynamics: CO: 0.0-20 l/min, CI: 0.0-10 l/min/m², SV: 0-300 ml.
  • Environmental Conditions: Operating temperature: 10°C - 40°C, Humidity: 15% - 85% non-condensing.
  • Connectivity: USB 1.1, BP Wave Out for integration with standard monitoring systems.

Compliance and Approvals
  • CE approval and FDA clearance.
  • Complies with IEC and ISO standards for medical devices.

Conclusion
CNAP® sets new standards for continuous and noninvasive hemodynamic monitoring, offering a reliable, cost-effective, and user-friendly solution for various clinical settings.
See more

Catalog excerpts

CNAP® Monitor-1

the next generation of noninvasive MONITORING

 Open the catalog to page 1
CNAP® Monitor-2

...every beat counts CONTINUOUS NONINVASIVE HEMODYNAMIC CONTROL FULL HEMODYNAMIC PICTURE Hemodynamics Continuous noninvasive blood pressure waveform / trendview Cardiac Output CO, CI, SV, SI Vascular Resistance SVR, SVRI Dynamic Fluid Management PPV, SVV Continuous Blood Pressure: Sys, Dia, MAP, Pulse and Upper arm NBP: Sys, Dia CONVENIENT CNAP® FINGER SENSOR EASY-TO-USE AND QUICK > Quick set-up and error-free application > Blood pressure waveform and values immediately available ACCURATE AND RELIABLE > Comparable with invasive clinical standards1-11- 21 > Reliable tracking (e.g. in patients...

 Open the catalog to page 2
CNAP® Monitor-3

...the next generation of noninvasive monitoring EASY-TO-USE QUICK START UP COST EFFECTIVE PROVEN ACCURACY IN CLINICAL SETTINGS FAST & ACCURATE HEMODYNAMIC OVERVIEW 16,17 > CNAP® measurements are comparable to invasive arterial line measurements in terms of continuity, accuracy and waveform dynamics.1,2,3 > Early recognition15 > Fast intervention > Detection of hemodynamic reactions > ...without arterial catheter > CNAP® delivers reliable results for the efficient treatment of ICU and ER patients.4,5, 6,7 > CNAP® provides immediate hemodynamic status and detects blood pressure drops during the...

 Open the catalog to page 3
CNAP® Monitor-4

TECHNICAL SPECIFICATIONS NBP – OSCILLOMETRIC BLOOD PRESSURE Measuring range Sys: Adult 40 - 260 mmHg, Pediatric 40 - 230 mmHg Dia: Adult 20 - 200 mmHg, Pediatric 20 - 160 mmHg Degree of protection BF (defibrillation proof) CI SI SVRI sealed lead-gel, operating time: 2 hours (fully charged battery) Supply frequency ~50/60 Hz PHYSICAL Weight 7,5 kg (16,6 lbs) including accessories and cables Height 280 x 270 x 250 mm (11 x 10,6 x 9,8 inch) ENVIRONMENTAL Temperature operation: 10°C - 40°C (50°F - 104°F) storage: 0°C - 40°C (32°F - 104°F) Humidity operation: 15% - 85% non condensing storage: 15%...

 Open the catalog to page 4

All CNSystems Medizintechnik catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.