Cochlear™ Baha® Attract System-1

Cochlear™ Baha® Attract System Radiographer’s instructions for MRI The Cochlear™ Baha® Attract System is a magnetic bone conduction implant system. The system includes an osseointegrated BI300 Implant and a BIM400 Implant Magnet that are implanted beneath the skin. A Baha sound processor and a Sound Processor (SP) Magnet are worn on the head (see Fig. 1). BIM400 Implant Magnet SP Magnet These guidelines are intended for radiologists performing MRI scans on a patient with the Cochlear Baha Attract System. Please read this information carefully. For more information, contact Cochlear.  MRI Safety Information The sound processor and SP Magnet must be removed before entering a room where an MRI scanner is located. Non-clinical testing has demonstrated that the BIM400 Implant Magnet, in combination with a BI300 Implant, is MR Conditional. It can be scanned safely under the following conditions. Scanning under other conditions may result in severe patient injury or device malfunction. BI300 Implant Baha sound processor Figure 1 • Static magnetic field of 1.5 Tesla only • Maximum spatial gradient field of 26600 Gauss/cm (266 T/m) • Maximum switched gradient slew rate per axis of 200 mT/m/ms • Maximum switched gradient amplitude per axis of 45 mT/m • Maximum MR System reported whole body averaged specific absorption rate (SAR) of 2.0 W/kg (Normal Operating Mode) Additional instructions essential to safe use in the MR environment: Under the scan conditions defined above, the BIM400 Implant Magnet is expected to produce a maximum temperature rise of 2.1 °C after 15 minutes of continuous scanning. In non-clinical testing, the BIM400 Implant Magnet produced a temperature rise of less than 2.1 °C (extrapolated) at a maximum whole body averaged specific absorption rate (SAR) of 2.0 W/kg (extrapolated) assessed by calorimetry for 15 minutes of MR scanning in a 1.5 Tesla Intera, Philips Medical Systems (Software: 12.6.1.3, 2010-12-02) MR Scanner. In non-clinical gradient-induced heating testing, the BIM400 Implant Magnet produced a temperature rise (extrapolated) of less than 4.5 °C at a time rate of change of the theoretical maximum worst-case gradient magnetic field dB/dt (extrapolated) of 200 T/s during 30 min. of continuous exposure in a test laboratory system (Pulsed Magnetic Field Generator) equivalent with a gradient system of a 1.5 Tesla MR system. In non-clinical testing with the implant magnet in place, the image artefact caused by the device extends approximately 11.5 cm (4.5 in.) from the BIM400 Implant Magnet when imaged with a gradient echo pulse sequence and a 1.5 Tesla MRI system (see Fig. 2). The artefact is reduced to 1.2 cm from the implant when the implant magnet is removed.  MR System manufacturers may claim that scanning patients with implanted devices is generally contraindicated. This is a general precautionary claim due to the fact that MR System manufacturers are unable to ensure safety for all types of implantable devices. Cochlear has performed specific testing for the above implants and established the necessary SAR safety limits as outlined. Recently available MR Systems are able to monitor SAR levels. The MR System manufacturer should be able to provide advice on how to maintain SAR levels with their system. Figure 2 Cochlear Bone Anchored Solutions AB Konstruktionsvägen 14, 435 33 Mölnlycke, Sweden Tel: +46 31 792 44 00 Fax: +46 31 792 46 95 Regional offices: Cochlear Ltd (ABN 96 002 618 073) 1 University Avenue, Macquarie University, NSW 2109, Australia Tel: +61 2 9428 6555 Fax: +61 2 9428 6352 Cochlear Americas 13059 E Peakview Avenue, Centennial, CO 80111, USA Tel: +1 303 790 9010 Fax: +1 303 792 9025 Cochlear AG EMEA Headquarters, Peter Merian-Weg 4, 4052 Basel, Switzerland Tel: +41 61 205 8204 Fax: +41 61 205 0405 Cochlear Latinoamerica, S. A. International Business Park Building 3835, Office 403, Panama Pacifico, Panama Tel. +507 830 6220 Fax: +507 830 6218 www.cochlear.com Ardium, Baha, Baha SoftWear, BCDrive, DermaLock, EveryWear, Vistafix and Windshield are either trademarks or registered trademarks of Cochlear Bone Anchored Solutions AB. Cochlear, SmartSound, True Wireless, Hear now. And always and the elliptical logo are either trademarks or registered trademarks of Cochlear Limited. © Cochlear Bone Anchored Sol

 Open the catalog to page 1

All Cochlear catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.