Overview: The CODAN ARGUS 606S is a syringe
infusion pump designed for use in various medical settings such as intensive care, anesthesia, and standard care. It supports Total Intravenous Anesthesia (TIVA) and dose calculation, enhancing patient safety and drug management efficiency.
Technical Specifications:- Performance: The pump offers a flow rate of 0.1 to 1,100 ml/h with precise dosing units and allows for infusion volume adjustments from 0.1 to 9,999 ml. It supports bolus administration and purging of the infusion line.
- Accuracy: The device maintains an accuracy of ±2% at ≥ 1 ml/h, with technical deviation under ±1%.
- History and Interface: It logs up to 1,000 events and connects to medical PCs or PDMS via RS-232 or optional Ethernet.
- Operation: Features a monochrome LCD display showing flow rate, infused volume, and other critical data. The menu is intuitive and configurable.
- Safety: Includes automatic pressure release, visual and audible alarms, and a Dose Error Reduction System (DERS) for 256 medications.
- Power Supply: Operates on a 1,800 mAh NiMH battery with a 6-hour operation time at 25 ml/h and a 9-hour charging time.
- Product Specifications: Dimensions are 320 x 100 x 180 mm, with a weight of 2.2 kg. It is made of high-performance plastic and is suitable for various environmental conditions.
Compliance and Certification: The device complies with multiple safety and electromagnetic compatibility standards, including EN 60601-1 and EN 60601-1-2. It is CE marked and certified under ISO 13485 and ISO 9001.
Accessories: Includes docking stations for power supply and monitoring, and an attachment system for pole and rail systems. Software support is provided through ARGUSservice and ARGUSmedDB for maintenance and medication database management.
See more