Fact Sheet Syringe Pumps

Fact Sheet Syringe Pumps

Fact Sheet Syringe Pumps

Product catalog summary
Technical Data Description: The A616S InCare Syringe Pumps are available in two product variants: InCare and TCI. They support dosing units such as g, mg, µg, ng, IU, and mmol, with infusion rates ranging from 0.1 to 1,500 ml/h. The infusion volume can be set between 0.1 to 9,999 ml, and infusion time ranges from 1 minute to 99 hours and 59 minutes. The device allows for manual or automatic bolus administration and purging of the infusion line.
Performance Data: The pumps offer an accuracy of ±2% with CODAN qualified syringes and ±5% with customer qualified syringes. They feature a Keep Vein Open (KVO) rate configurable from off to 5.0 ml/h and an alarm system for unused pumps.
History and Interface: The device logs up to 1,000 events with timestamps and can connect to central systems via a nurse call interface. It includes an RS-232 interface for configuration and can connect to docking stations for Ethernet communication.
Operation: The pump features a monochrome LCD display with adjustable brightness and a night mode. It supports multiple infusion modes, including standard operation, dose calculation, TIVA, and TCI, with a medication database required for some modes.
Safety: Safety features include automatic pressure release, visual and audible alarms, DEFI proofing, and a key lock. The pressure limit for occlusion is adjustable between 200 to 1,200 mbar.
Power Supply: The device operates on a 1,800 mAh NiMH battery, providing up to 9 hours of operation at 5 ml/h. It supports mains power supply from 100 to 240 V.
Product Specification: The pump measures 320 x 100 x 180 mm and weighs 2.0 kg with the battery. It operates in temperatures from 5°C to 40°C and is compliant with various safety and usability standards.
Compliance: The device meets standards such as IP22, IEC 60601-1, and EN 60601-2-24, among others.
Accessories: Available accessories include CODAN docking stations and the ARGUSservice software for maintenance and configuration.
See more

Catalog excerpts

Fact Sheet Syringe Pumps-1

Syringe Pumps A616S InCare A616S TCI Fact Sheet

 Open the catalog to page 1
Fact Sheet Syringe Pumps-2

Technical Data Product variants Dosing units Infusion rate Infusion volume Infusion time Programming Automatic rate calculation Bolus administration Bolus rate Bolus volume Purging of the infusion line InCare, TCI g, mg, µg, ng, IU, mmol 0.1 to 1’ 500 ml/h 0.1 to 999.9 ml/1‘000 to 9‘999 ml 1 min to 99 h 59 min Rate in ml/h, volume in ml, duration in h and min On the basis of volume and time Manual or automatic 0.1 to 1’ 500 ml/h 0.1 to 50 ml 0.1 to 1’ 500 ml/h Purge max volume: 1.0 to 5.0 ml/h ±2% (at ≥ 1 ml/h) ±5% (at ≥ 1 ml/h) 0.5 to 1.2 ml Off or 0.1 to 5.0 ml/h Off or 1 to 60 min Accuracy...

 Open the catalog to page 2