STEM RS Reaction Stations
1 /11Pages

STEM RS Reaction Stations

STEM RS Reaction Stations
1 /11Pages

Catalog excerpts

STEM RS Reaction Stations-1

STEM RS Reaction Stations Equipment for parallel synthesis The STEM RS series Reaction Stations enable parallel synthesis to be carried out by offering the same controlled temperature and stirring rates at several reaction positions simultaneously. The STEM RS Reaction Stations give you a choice of: • 6 to 50 positions • Working sample columes of between 10-30ml (but up to 250ml for RS600) • Operational temperature range of ambient to 150ºC • Optional higher temperature models for up to 300ºC • Powerful stirring rate of between 400 - 2000rpm • Wide range of accessories Page 66 Page 67 Page 68 Page 69 Page 70 Page 71 Page 72 Page 74 STEM RS Reaction Stations STEM RS600 Reaction Station STEM RS900 Reaction Station STEM RS1000 Reaction Station STEM RS2500 Reaction Station STEM RS5000 Reaction Station STEM RS9000 Reaction Station Accessories for RS series Reaction Stations Find out more! Please scan the QR/Mobile Tag with your smartphone for more information Electrothermal Catalogue

 Open the catalog to page 1
STEM RS Reaction Stations-2

RS600, RS900, RS1000, RS2500, RS5000, RS9000 STEM RS Reaction Stations The Stem RS Reaction Stations enable parallel synthesis to be carried out by offering the same controlled temperature and stirring rates at several reaction positions simultaneously. They can be used for a wide range of applications from simple synthesis to process optimisation. The RS9000 is the exception in that it carries out controlled heating and shaking, as opposed to stirring. The STEM RS Reaction Station range accommodates sample sizes from 2ml to 250ml in a wide range of vessel sizes and heating formats. Adaptor sleeves...

 Open the catalog to page 2
STEM RS Reaction Stations-3

Reaction Station The RS600 is a six position reaction station designed for 57.5mm diameter vessels (also 40mm and other diameter vessels with appropriate adaptor sleeves), and With a controlled temperature range from ambient +5°C to 250°C, it has a powerful stir speed from 400 to 2000rpm, including a bi-directional stirring option. It has either manual control or external control via the RS232/RS485 interface ports. Optional PC-based external control software is available to schedule stir/heat profiles over varying time delays. The RS600 can be used with a reflux and inerting head accessory,...

 Open the catalog to page 3
STEM RS Reaction Stations-4

Reaction Station The RS900 is a 10 position reaction station designed for 24mm/25mm diameter vessels (also 16mm and other diameter vessels with appropriate adaptor sleeves), and sample The unit has a controlled temperature range from ambient to 150°C, along with a powerful stir speed from 400 to Technical Information Stirred positions Tube diameter Tube diameter sleeves Sample volume Stir speed range Soft start (to full ramp) Temperature range (ambient) Temp stability Time to max/min temp Interface port • 10 position reaction station • Can accommodate 16mm and other diameter vessels with appropriate...

 Open the catalog to page 4
STEM RS Reaction Stations-5

Reaction Station The RS100 is a 10 position reaction station designed for 24mm/25mm diameter vessels (also 16mm and other diameter vessels with appropriate adaptor sleeves), and sample sizes from 10ml to 30ml, along with a controlled temperature range from ambient to 150°C. The unit has a powerful stir speed from 400 to 2000rpm, and permits both manual, and external control via the RS232/RS485 interface ports. It has a compact footprint for easy integration onto a robotic platform. The RS100 is also available as a high temperature RS1000H option with temperature range from ambient to 300°C. Technical...

 Open the catalog to page 5
STEM RS Reaction Stations-6

Reaction Stations The RS2500 is a 25 position reaction unit & the RS2400 a 24 position reaction station, designed for 24mm/25mm diameter vessels. They both accommodate 16mm and other diameter vessels with appropriate adaptor sleeves), and sample sizes from 10ml to 30ml. They have a controlled temperature range from ambient to 150°C, along with a powerful stir speed from 400 to Both manual and external control are permitted via the RS232/ RS485 interface ports and they have a compact footprint for easy integration onto a robotic platform. Technical Information Stirred positions Tube diameter Tube...

 Open the catalog to page 6
STEM RS Reaction Stations-7

50 position reaction station Can accommodate 16mm and other diameter vessels with appropriate adaptor sleeves Sample sizes from 10ml to 30ml Controlled temperature range from ambient Powerful stir speed from 400 to 2000rpm interface ports Compact footprint for easy integration onto a robotic platform Reaction Station The RS5000 is a 50 position reaction station designed for 24mm/25mm diameter vessels (also 16mm and other diameter vessels with appropriate adaptor sleeves), and sample sizes from 10ml to 30ml. It has a controlled temperature range from ambient to 150°C and a powerful stir speed...

 Open the catalog to page 7
STEM RS Reaction Stations-8

STEM RS9000 Key Features Heater/Shaker Reaction Station The RS 9000 Heater/Shaker Reaction Station can be used within a robotic workstation or as a stand-alone apparatus in the lab. On a robotic platform, heating and shaking cycles can be controlled by external software or as part of a fully automated system through the RS232/ RS485/ GSIOC ports; for standalone use, there is the additional option of controlling heating and shaking cycles via the user friendly touchscreen. The CTC panel (Capacitance Touch Control) of the touchscreen enables the temperature and shaking speeds to be changed using...

 Open the catalog to page 8
STEM RS Reaction Stations-9

Heater/Shaker Reaction Station Safety Features The RS9000 has a thermal cut-off that eliminates runaway conditions. The 'Hot block' warning via a highly visible warning display icon alerts you to when the block temperature is above 50°C, even when the apparatus is unplugged from the power supply. The RS9000 can be stopped rapidly in case of emergency by pressing down on the front sliding door; the front display will indicate "Door Open" and immediately stop. Heating and stirring can be reset after stopping by closing the door and pressing the function key zones on the front panel to reactivate....

 Open the catalog to page 9
STEM RS Reaction Stations-10

Accessories For RS Series Reaction Stations Part Code Accessory RS Model 600 900 1000 AT60067 Stir bar PTFE coated15mm x 4mm • ATS10101 Adaptor sleeve 11mm - 25mm (10 pack) • ATS10210 Adaptor sleeve 12mm - 25mm (10 pack) • ATS10211 Adaptor Sleeve 25mm - 23mm (10 pack) • ATS10212 Adaptor Sleeve 25mm -18/16mm (10 pack) • PS80087 Temperature probe • • • PS80155 Adaptor sleeve RS900 25-22mm (10 pack) • AZ6745 Power cable without plug • • • AZ6746 115V Power cable with US plug • • • AZ6747 230V Power cable with EU plug • • • AZS4024 Fuse 8A SLO BLO • • AZS4010 Motor • AZS4100 PCB Display • AZS4101...

 Open the catalog to page 10

Archived catalogs

  1. Controllers

    6  Pages

  2. Tecal 650S/H

    1  Page

  3. Tecal 650F

    1  Page

  4. Tecal 425S/H

    1  Page

  5. Tecal 425F

    1  Page

  6. TechneWorks

    1  Page

  7. Electromantle

    8  Pages

  8. Stirrers

    7  Pages