Catalog excerpts

Tecal S and H range Dri-Block Calibrator-1

tecal portable dri-block® calibrators Tecal S and H range Dri-Block Calibrator This range of temperature calibrators is ideal for calibrating temperature sensors used in the food and pharmaceutical industries in addition to calibrating any sensors used in the temperature range outlined in the specifications below. S Version: Set required Temperature and Calibrate H Version: Set required Temperature and Calibrate; also programmable for switch test and ramp rate etc. Tecal 140S/H The Tecal 140S provides a complete system for calibrating most types of thermal sensors used in the temperature range of -40°C to 140°C which includes “K” type thermocouples commonly used in the food industries, cold storage rooms and environmental monitoring systems. 140H Where automation in both the field and laboratory are required, the combination of the Tecal 140H with the UPI (see page 13) saves time and money. The user can set the program and leave the unit to calibrate the probes, automatically storing the results in memory. This allows the user to attend to other tasks and when convenient download the results to a computer to print the calibration certificate. Using advanced peltier technology and state-of-the-art mechanical and electrical components, these calibrators can rapidly cover the complete temperature range where speed is of the essence without loss of accuracy or stability. The heater block with a defined measuring zone of 50mm from the bottom of the block allows for different length/active area sensors. Although the quoted accuracy and stability is ±0 .2°C & ±0.05°C respectively, one can often achieve an accuracy of ±0.1°C and a stability of ±0.02°C with high class RTDs and thermocouples. Technical Specification – Note improved Specification 2011 Minimum temperature 45°C below ambient1 (-60°C cooling) Maximum temperature 140°C Temperature accuracy in measuring zone. ±0.2°C Temperature uniformity in measuring zone ±0.2°C2 Measuring zone 0 to 50mm from base of well Temperature stability after 10min ±0.05°C Display resolution 0.1°C Heating rate, 20°C to 100°C 5 minutes Cooling rate, 100°C to 0°C 9 minutes Programmable ramp rate, °C/min 0.1 to 10, on H version Switch test on H version Comms port, 9 way D type Full bi-directional RS-232 Weight 14.0(S), 14.4(H) kg Dimensions H x W x D, mm 285 x 190 x 426 In a maximum ambient temperature of 20°C and when using the CH-5 Chiller a temperature of -40°C can be achieved. See page 9 for full range of inserts available. Ordering Information Product Model Voltage Hz Watts Code FDB140SD FDB140SP FDB140SY FDB140HD FDB140HP FDB140HY Accessories FCALCASE TECAL 140S TECAL 140S TECAL 140S TECAL 140H TECAL 140H TECAL 140H Hard Carry case for Tecal H and S models

 Open the catalog to page 1

Archived catalogs

  1. Controllers

    6  Pages

  2. Tecal 650S/H

    1  Page

  3. Tecal 650F

    1  Page

  4. Tecal 425S/H

    1  Page

  5. Tecal 425F

    1  Page

  6. TechneWorks

    1  Page

  7. Electromantle

    8  Pages

  8. Stirrers

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.