1. Economical Gas Chromatograph Systems:
  • These systems are designed to offer quality without compromising on price.
  • Available in different configurations with power options of 115 VAC and 230 VAC.
2. System Configurations:
  • A. Thermal Conductivity Detector (TCD) GC System:
    • Features user-replaceable filaments and electronic pressure control (EPC) for carrier gas.
    • Includes a one-meter silica gel column and an on-column injector.
    • Column oven programmable up to 572°F with fast cool-down fans.
  • B. Flame Ionization Detector (FID) GC System:
    • Suitable for a range of analyses from methane to heavy hydrocarbons.
    • Includes programmable EPCs for carrier and combustion gases.
    • Column oven accepts cage diameters up to 4" and is programmable to 572°F.
  • C. Single-Filament TCD System:
    • Operates at ambient temperature and is ideal for field operations.
    • Features a one-meter packed column and USB connection for data acquisition.
3. Chromatography USB Data Systems:
  • Available in one-channel and six-channel models.
  • Compatible with any manufacturer's GC or HPLC detector.
  • Includes PeakSimple™ chromatography software for easy data acquisition.
  • Data acquisition rates up to 50 Hz for one or two channels, and 20 Hz for all six channels.
4. Cleaning Kits:
  • Flame Detector Cleaning Kit: Includes jet reamers, wire minibrushes, and a dual-ended handle.
  • Fine Wire Cleaning Kit: Contains stainless steel wires of various sizes and a pin vise for cleaning syringes and needles.
Contact Information: For technical support and inquiries, contact numbers for the US, Canada, India, and the UK are provided.
See more

Catalog excerpts

Economical Gas Chromatograph (GC) Systems-1

- Complete analytical system with dry-channel PeakSimple™ - Durable, all-aluminum construction A. Thermal Conductivity Detector (TCD) GC System - TCD with user-replaceable filaments - Carrier gas Electronic Pressure Control (EPC) - One-meter silica gel column - On-column injector This traditional four-filament TCD can heat up to 527°F (275°C). The built-in single-channel PeakSimple data system provides easy and powerful data acquisition, as well as temperature programming for the column oven. The column oven is programmable to 572°F (300°C) with unlimited ramps and holds, and is equipped with fast cool-down fans. EPC for the carrier gas provides rock-solid retention time reproducibility. B. Flame Ionization Detector (FID) GC System - On-column injector for Vs" packed and 0.53 mm wide-bore capillary columns Chromatography USB Data Systems No more paper chart recorders - Low-cost data systems for use with any manufacturer’s GC or HPLC detector - PeakSimple™ chromatography software for Windows®—easy USB 2.0 connection to PC One-Channel Model. Eight TTL (Transistor-Transistor Logic) and four optional relay outputs wired to a bank of eight single-pole, dual-throw mechanical relays with screw terminals for easy connection to any device. A remote start input allows run initiation from the user’s GC or FIPLC system. Data can be acquired at rates up to 50 Hz. Six-Channel Model. The eight TTL outputs are wired to a bank of eight single-pole, dual-throw mechanical relays with screw terminals for easy connection to any user device. Four remote start inputs allow run initiation from the user’s GC or HPLC system. Each of the six channels of data can be randomly assigned to one of four time bases, which allows independent start and stop times for four separate instruments. Data can be acquired at rates up to 50 Hz per channel for one or two channels or 20 Hz for all six channels. Models are not compatible with older USB 1.0 or 1.1 compliant ports. The 230 volt system is supplied with a UL, CSA, and CE/VDE approved universal power supply, which will operate on any AC voltage from 100 to 250 volts. What’s included: hardware and software. Fine Wire Cleaning Kit Use this kit to clean syringes, needles, and more. Includes ten 0.15-mm SS wires, ten 0.25-mm SS wires, ten 0.50-mm SS wires, and a pin vise to hold wire during use. Cole-Parmer® US Toll-free: 800-323-4340 • Outside the US: 847-549-7600

 Open the catalog to page 1

All Cole-Parmer catalogs and technical brochures

  1. Digestion

    1  Page

  2. Cylinders

    1  Page

  3. Containers

    1  Page

  4. Carboys

    1  Page

  5. Cryogenics

    1  Page

  6. Centrifuges

    1  Page

  7. Crucibles

    1  Page

  8. Compressors

    1  Page

  9. IKAC atalog

    28  Pages

  10. Lab Essentials

    100  Pages

  11. Carts

    1  Page

  12. Cable Ties

    1  Page

  13. Bottles

    1  Page

  14. Beakers

    1  Page

  15. Balances

    1  Page

  16. Bags

    1  Page

  17. EW-33684-26

    1  Page

  18. Flasks

    1  Page

  19. EW-25210-00

    1  Page

  20. EW-07630-32

    1  Page

  21. EW-12911-18

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.