Catalog excerpts

Microtitre Shaking Incubator, Ideal shaking action for microtitre plates Combined Incubator shaker Optimised performance to minimise sample Digital display for temperature and speed Integrated timer Shaking action is ideal for mixing microtitre plates, combining Retractable platform for easy loading and a high speed action between 250 and 1250rpm with a tight The SI505 has been designed specifically to combine a bench top Reciprocating laboratory incubator with the specific mixing action required for microtitre plates. orbit of 1.5mm. This enables even the smallest of vessels to adequately mixed, be it well plates or microtubes. The SI505 has independent control of speed and temperature to avoid accidental temperature adjustment. Speed is microprocessor controller and set via the digital LED control panel. The unit also incorporates a versatile timer, which can be set from 1 second to 9 days, once the timer has run down, an alarm will sound and the shaking action will cease, for safety reasons the incubator will continue to run. The temperature of the incubator can be set, via the digital LED control panel, between ambient temperature +7ºC and 60ºC. Careful control of the air distribution within the incubator ensures temperature uniformity throughout the sample chamber. To minimise sample evaporation the SI505 is supplied with stainless steel water trays, these are strategically placed within the unit to maintain a humidity of up to 80%, thus dramatically reducing sample evaporation over a 24 hour period. The SI505’s stainless steel platform is retractable, this allows easier access to samples at the back of the incubator. During operation the platform is securely locked in place, but can be easily released when required. The platform will comfortably and securely accommodate up to four microtitre plates on the non slip mat. Or sample tube racks are available which will accommodate all common tube sizes. The SI505 also features a USB connection which allows the incubator to be connected to a PC for long term monitoring of the incubator temperature, over night of weekends for example.
Open the catalog to page 1
SI505_Microtitre Shaking Incubator, Technical Specification_ Temperature range Samples Temperature display resolution Temperature fluctuation Temperature variation Temperature precision Speed range Speed control J Timer ' Orbit diameter, mm ■ Platform size, mm I Relative humidity | Internal dimensions, mm (w x d x h) Maximum load, kg Overall dimensions, mm (w x d x h) | Net weight, kg Heater power, W I Electrical supply IP Rating Ambient + 7°C to 60°C 4 x Microtitre plate or 2 x microtube racks ± 0.5°C at 37°C <0.6°C at 37°C ± 0.5°C at 37°C 250 to 1250rpm Digital set in 10rpm...
Open the catalog to page 2All Cole-Parmer catalogs and technical brochures
-
SM5/ Mini stirrer
1 Pages
-
Vortex Mixers - SA7, SA8
2 Pages
-
Shaking incubator, SI500
2 Pages
-
Hotplate UC150 and US150
1 Pages
-
Homogenisers
4 Pages
-
Flocculators - SW5, SW6
1 Pages
-
Hybridisation oven, SI30H
2 Pages
-
Incubator, SI60, SI60D
1 Pages
-
Handheld Homogeniser - SHM1
1 Pages
-
HM Series of Heating Mantles
1 Pages
-
Colony Counter - SC6PLUS
1 Pages
-
Microcentrifuge, SCF2
1 Pages
-
H2 offers 2015
4 Pages
-
Centrifuge
4 Pages
-
Melting Point
8 Pages
-
SI505 MTP Shaking Incubator
4 Pages
-
Digital Burette, BT30, BT50
4 Pages
-
SCT1 Temperature controller
1 Pages
-
Hotplate, Infra Red, CR300
1 Pages
-
SB161-3
1 Pages
-
SSM3 and SSM4
2 Pages
-
Bibbyjet Pipette Controller
3 Pages
-
SRC4
1 Pages
-
Mini Centrifuges spinner
1 Pages
-
Mini Centrifuges
4 Pages
-
SHM1
1 Pages
-
SHM2
1 Pages
-
Hotplates
1 Pages
-
SHM Probes
2 Pages
-
W6
1 Pages
-
HM Series
1 Pages
-
Colony Counter
1 Pages
-
SBHCONC/1
1 Pages
-
Aluminium blocks
1 Pages
-
SBH130DC and SBH200DC
1 Pages
-
SBH130
1 Pages
-
SBH130D/3 and SBH200D/3
1 Pages
-
Stuart Catalogue
152 Pages
-
Mini Stuart
4 Pages
-
BioCote®
3 Pages
-
Melting Point Range
8 Pages
-
SI505
4 Pages
-
SI500 Shaking Incubator
4 Pages
-
Colony Counters
4 Pages