Product catalog summary
Overview: The Hyfrecator® Product Catalog provides comprehensive details on the Hyfrecator® 2000 and its accessories, including ordering information, product specifications, and customer service contacts.
Ordering Information: Customers must provide a purchase order number, billing and shipping instructions, product catalog number, and pricing to place an order. Customer service is accessible via phone, fax, and email both domestically and internationally.
Hyfrecator® 2000 Features: The Hyfrecator® 2000 is noted for its precisely controlled power output and dual microprocessing technology, enhancing clinical outcomes and patient safety. It is available in various models with different voltage specifications.
Accessories: The catalog includes both disposable and reusable accessories such as pencil sheaths, electrodes, and smoke evacuation systems, each with detailed product numbers and specifications.
Terms and Conditions: ConMed products adhere to ISO13485 and European MDD standards. Prices and specifications may change, and credit terms are net 30 days where approved. Returns are accepted within 60 days, subject to a restocking charge and quality assurance inspection.
Mission and Quality Policy: ConMed is dedicated to enhancing healthcare quality through innovative products, focusing on customer satisfaction and shareholder equity growth. The company is committed to providing safe and effective products that meet stakeholder needs.
Training and Support: Instructional videos and operator manuals are available in multiple languages, and technical support is provided for Hyfrecator® 2000 units.
Product Specifications:
  • Needle Electrodes: Available in various types for pinpoint coagulation and desiccation, sold in packages of 5 or 6.
  • Ball Electrodes: Offered in different diameters and lengths for controlled coagulation, sold in packages of 1, 5, or 10.
  • Bipolar Forceps: Autoclavable for precise desiccation and coagulation, requiring a bipolar cord and foot switch.
Applications: The Hyfrecator® is used in various medical fields including dermatology, gynecology, ophthalmology, otolaryngology, proctology, urology, and dental/oral surgery for procedures such as lesion treatment, cyst removal, and tumor ablation.
Additional Resources: A glossary of terms and information on training courses for surgical techniques are provided.
Continuing Medical Education: The catalog offers continuing medical education for physicians across nearly all medical specialties, with contact information for inquiries.
Video Training: A video titled 'Common Dermatologic Procedures' provides step-by-step instructions for various dermatological procedures and can be ordered using Product 7-900-21-CD.
CD-ROMs: Two CD-ROMs, 'Hyfrecator® Dealer Training' and 'Office Electrosurgery,' offer guidelines and information on electrosurgery and dermatological procedures, available for order with specific product numbers.
Online Resources: ConMed's website provides valuable information for dealers and physicians, with contact available via email.
Customer Service: Contact details for customer service within and outside the U.S. are provided, including phone and fax numbers.
See more

Catalog excerpts

Hyfrecator-1

Product Catalog ELECTROLASE* HYFRECATOR* GENERAL PURPOSE FINE NEEDLE SHARP TIP PENCIL SHEATH ELECTRODE ELECTRODE To learn more about these innovative

 Open the catalog to page 1
Hyfrecator-2

Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235

 Open the catalog to page 2
Hyfrecator-3

Ordering Information To Place Your Order Return Goods Policy Please provide a purchase order number, billing and shipping instructions, terms, product catalog number and description, and pricing to Customer Service. All ConMed products, except products that are obsolete, discontinued, or damaged or specialty products, may be returned within 60 days after date of purchase for credit subject to the following: 1. copy of the invoice number and date of purchase and a Return Authorization A Number must accompany the returned goods with the reason for the return stated in writing. Contact ConMed Customer...

 Open the catalog to page 3
Hyfrecator-4

What makes the Hyfrecator 2000 different? ® - recisely Controlled Power Output — Improves clinical outcomes P - ual Microprocessing Technology — Continuously monitors the system for reliability and D patient safety Hyfrecator 2000 ESU (International Units Available) ® Service Options ConMed services only Hyfrecator 2000 units. Please call ConMed Technical Services: ® International Telephone: +1 (303) 699-7600, Option 3 E-mail: [email protected] Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235...

 Open the catalog to page 4
Hyfrecator-5

Training Tools Video — “Hyfrecator 2000 Inservice” - rovides setup instructions and other helpful tips for using the Hyfrecator P ® Hyfrecator 2000 Operator’s Manual - vailable in English, Spanish, French, Chinese, German, Dutch, Japanese, Swedish, A Italian, Portuguese. - ncludes safety precautions, terminology for systems and procedural configurations, I applications, maintenance, optional accessories, specifications and performance graphs. ® Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235

 Open the catalog to page 5
Hyfrecator-6

Hyfrecator Accessories for All Models ® Pencils/Handpieces — One-Year Warranty Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235

 Open the catalog to page 6
Hyfrecator-7

Smoke Evacuation System Smoke Evacuation System Accessories Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235

 Open the catalog to page 7
Hyfrecator-8

Disposable Hyfrecator Accessories ® Disposable Hyfrecator Accessories ® Disposable Pencil Sheaths Electrolase Disposable Electrodes — Sharp Tips ® Electrolase Sharp Tips — Non-sterile Disposable Hyfrecator tips ideal for pinpoint coagulation. White plastic base. ® Electrolase Disposable Electrodes — Blunt Tips ® Electrolase Blunt Tips — Non-Sterile Disposable Hyfrecator tips ideal for broad based coagulation. Dark gray plastic base. ® Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235

 Open the catalog to page 8
Hyfrecator-9

Reusable Hyfrecator Accessories ® Reusable Hyfrecator Accessories ® Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235

 Open the catalog to page 9
Hyfrecator-10

Reusable Hyfrecator Accessories ® Reusable Needle Electrodes Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235

 Open the catalog to page 10
Hyfrecator-11

Reusable Hyfrecator Accessories ® Reusable Ball Electrodes Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235

 Open the catalog to page 11
Hyfrecator-12

Bipolar Accessories Bipolar Forceps For precise desiccation and coagulation control. All forceps are autoclavable and require a bipolar cord and foot switch for operation. Cold sterilization may damage insulating material. Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235

 Open the catalog to page 12
Hyfrecator-13

Bipolar Accessories Bipolar Forceps (continued) Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235

 Open the catalog to page 13
Hyfrecator-14

HYFRECATOR PRODUCTS INDEX Customer Service: (within U.S.) Phone: 800.448.6506 • Fax 800.438.3051 • Customer Service: (outside U.S.) Phone: +1.315.797.8375 • Fax: 315.735.6235

 Open the catalog to page 14
Hyfrecator-15

Numerical Index 705A Fine Wire Needle 9 711B General Purpose Electrode with Protective Insulator 8 714 Extra Fine Needle Electrode 9 716 Long Desiccation Needle 9 138019 Short Ball Electrode 10 60-1771-001 Semkin Micro Tips, with Stops, Bipolar Forcep 11 60-1772-001 Semkin Straight, Bipolar Forcep 11 60-5108-001 IEC 320 Power Cord Set, European 3 60-5108-002 IEC 320 Power Cord Set, British 3 60-5108-003 IEC 320 Power Cord Set, Italian 3 7-100-12BX Electrolase* Sharp Tips —Non-sterile, 100/box 7 7-100-12CS Electrolase Sharp Tips — Non-sterile, 12 boxes/case 7 7-100-8BX Electrolase Sharp Tips —Sterile,...

 Open the catalog to page 15
Hyfrecator-16

Numerical Index 7-900-100 Hyfrecator 2000 100V, Includes power cord. 3 7-900-115 Hyfrecator 2000 115v, Includes power cord 3 7-900-13 Hyfre-Vac* II Hand Held Tubing Non-sterile, 5/case 6 7-900-14 Hyfre-Vac II Filter Pack, 2/case, Sold by case only 6 7-900-21-CD Video — "Common Dermatologic Procedures" CD 4 7-900-220 Hyfrecator 2000 220v, Power cord sold separately. 3 7-900-230 Hyfrecator 2000 230-240v, Power cord sold separately 3 7-900-25-CD Video — "Hyfrecator 2000 Inservice" CD 4 7-900-5 Autoclavable, Reusable Hand Control Pencil 5 7-900-6 Autoclavable, Reusable Foot Control Pencil 5 7-900-OM-CHN...

 Open the catalog to page 16

Archived catalogs

  1. ARTHROSCOPY

    232  Pages