Physician’s

Physician’s
1 / 92 PagesView full catalog

Physician’s

Product catalog summary
Overview: The Physician’s Pocket Reference Guide for Zenith Endovascular Grafts provides comprehensive information on the specifications, deployment, and use of endovascular grafts for aortic repair. The guide underscores the importance of durable aortic repair, aligning with the Zenith design philosophy.
Specifications: The guide details specifications for various endovascular grafts, including Thoracic, Visceral, Abdominal, and Iliac Legs. It includes measurements and compatibility requirements such as diameter, length, and introducer sheath sizes.
Procedures: Detailed instructions are provided for deploying the Zenith Alpha Thoracic Endovascular Graft. Key steps involve positioning the Lunderquist Extra-Stiff DC Wire Guide, introducing and unsheathing the proximal component, and ensuring no twisting occurs during the procedure.
Contraindications: Contraindications include known sensitivities to materials like polyester, polypropylene, nitinol, or gold, and conditions that may lead to graft infection.
Accessories: A list of accessories for endovascular procedures is provided, including needles, introducer sets, dilators, catheters, embolization coils, balloon catheters, vascular retrievers, and wire guides, each described with its specific use and compatibility.
Recommendations: The guide advises consulting the Instructions for Use (IFUs) for detailed procedural instructions, contraindications, warnings, and potential adverse events. It also suggests contacting local Cook representatives or Customer Service for product availability and additional information.
Deployment Procedure Overview: The deployment process for the Zenith Alpha Thoracic Endovascular Graft includes steps such as loosening the safety-lock knob, removing the introducer system, positioning the distal component, and using a molding balloon for proper graft placement.
Specifications and Indications for Use: Specifications include indications for use in patients with abdominal aortic or aortoiliac aneurysms suitable for endovascular repair, specific measurements for aortic fixation site diameter, and contraindications for patients with material sensitivities or systemic infections.
Product Specifications: Detailed specifications for different graft models are provided, including order numbers, reference part numbers, dimensions, introducer sheath diameters, and market availability.
Product Specifications for Zenith Flex AAA Endovascular Graft: Specifications include main body grafts available in various diameters and lengths, with specific introducer sheath sizes. Ancillary components like converters and iliac leg extensions are also detailed.
Deployment Procedures for Zenith Flex AAA: Procedures include main body placement under fluoroscopy, contralateral iliac wire guide placement, main body proximal deployment, contralateral iliac leg placement, and molding balloon insertion.
Indications and Contraindications: Indications include secondary endovascular interventions for prior aneurysm repairs, while contraindications cover allergies to specific materials and systemic infections.
Recommendations: Emphasizes consulting the Instructions for Use booklet for detailed deployment protocols, indications, contraindications, warnings, and precautions.
See more

Catalog excerpts

Physician’s-1

ENDOVASCULAR GRAFTS United States pocket reference guide

 Open the catalog to page 1
Physician’s-2

Achieving a durable aortic repair is the foundation of the Zenith design philosophy. CAUTION: Federal (USA) law restricts the use of these devices to sale by or on the order of a physician. View the Instructions for Use for a thorough examination of the procedural instructions, intended use, contraindications, warnings and precautions and potential adverse events. Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. For complete instructions for use (IFUs), go to ifu.cookmedical.com/ifuPub/ searchIFU.jsf. Additional...

 Open the catalog to page 2
Physician’s-5

Zenith Thoracic Zenith Thoracic Endovascular Grafts

 Open the catalog to page 5
Physician’s-7

Zenith Alpha THORACIC ENDOVASCULAR GRAFT

 Open the catalog to page 7
Physician’s-8

Indications for UseAneurysm or ulcer length > 20 mm

 Open the catalog to page 8
Physician’s-9

Proximal Components Aortic Introducer Vessel Sheath Order Reference OD Diameter Length ID/OD Number Part Number mm mm mm Fr (mm)/mm Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details.

 Open the catalog to page 9
Physician’s-10

Proximal Components (continued) Aortic Introducer Vessel Sheath Order Reference OD Diameter Length ID/OD Number Part Number mm mm mm Fr (mm)/mm Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. Introduction System for Proximal Components 24-30 mm grafts: 16 Fr (5.3 mm) ID/6.0 mm OD 32-38 mm grafts: 18 Fr (6.0 mm) ID/7.1 mm OD 40-46 mm grafts: 20 Fr (6.7 mm) ID/7.7 mm OD

 Open the catalog to page 10
Physician’s-11

ZTA-P-(diameter)-(length)-W Note: All measurements are in millimeters. Red numbers indicate gap lengths. Gap lengths are approximate.

 Open the catalog to page 11
Physician’s-12

Proximal Components (continued) 38, 40 mm

 Open the catalog to page 12
Physician’s-13

Proximal 4 mm Tapered Components Aortic Introducer Vessel Proximal Distal Sheath Order Reference OD Diameter Diameter Length ID/OD Number Part Number mm mm mm mm Fr (mm)/mm Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. Introduction System for Proximal 4 mm Tapered Components 30 mm grafts: 16 Fr (5.3 mm) ID/6.0 mm OD 32-38 mm grafts: 18 Fr (6.0 mm) ID/7.1 mm OD 40-46 mm grafts: 20 Fr (6.7 mm) ID/7.7 mm OD

 Open the catalog to page 13
Physician’s-14

Proximal 4 mm Tapered Components 30 mm ZTA-PT-XX-YY-ZZZ-W ZTA-PT-(proximal diameter)-(distal diameter)-(length)-W Note: All measurements are in millimeters. Red numbers indicate gap lengths. Gap lengths are approximate.

 Open the catalog to page 14
Physician’s-15

Proximal 4 mm Tapered Components (continued)

 Open the catalog to page 15
Physician’s-16

Proximal 4 mm Tapered Components (continued) 40 mm

 Open the catalog to page 16
Physician’s-17

Proximal 4 mm Tapered Components (continued)

 Open the catalog to page 17
Physician’s-18

Distal Components Aortic Vessel Order Reference OD Number Part Number mm Distal Component Diameter mm Distal Component Length mm Introducer Sheath ID/OD Fr (mm)/mm Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. Introduction System for Distal Components 28-30 mm grafts: 16 Fr (5.3 mm) ID/6.0 mm OD 32-38 mm grafts: 18 Fr (6.0 mm) ID/7.1 mm OD

 Open the catalog to page 18
Physician’s-19

Distal Components Note: All measurements are in millimeters. Red numbers indicate gap lengths. Gap lengths are approximate.

 Open the catalog to page 19
Physician’s-20

Distal Components (continued)

 Open the catalog to page 20
Physician’s-21

Order Reference Number Part Number Aortic Vessel OD mm Diameter Length mm mm Introducer Sheath ID/OD Fr (mm)/mm Zenith Alpha TAA 26 mm Diameter G35511 ZTA-DE-26-104-W Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. Introduction System for Distal Extensions 26-30 mm grafts: 16 Fr (5.3 mm) ID/6.0 mm OD 34-38 mm grafts: 18 Fr (6.0 mm) ID/7.1 mm OD 42-46 mm grafts: 20 Fr (6.7 mm) ID/7.7 mm OD

 Open the catalog to page 21
Physician’s-22

ZTA-DE-XX-YYY-W ZTA-DE-(diameter)-(length)-W Note: All measurements are in millimeters. Red numbers indicate gap lengths. Gap lengths are approximate.

 Open the catalog to page 22
Physician’s-23

Deployment Overview ll POSITION A LUNDERQUIST EXTRA-STIFF DC WIRE GUIDE IN THE AORTIC ARCH Through the pigtail flush catheter, replace the standard guide wire with an extra-stiff, .035, 260 or 300 cm double-curved Lunderquist wire guide up to the level of the aortic arch and remove the pigtail. (5 POSITION THE PROXIMAL COMPONENT Introduce the flushed, hydrated introduction system for the proximal component over the extra-stiff double-curved Lunderquist wire guide and advance until you reach the desired graft position. Caution: To avoid twisting the graft, never rotate the introduction system...

 Open the catalog to page 23
Physician’s-24

Deployment Overview* (continued) 8 RELEASE THE DISTAL COMPONENT Use the 1-2-3 deployment sequence. 1. To release the distal attachment, hold the black gripper and loosen the black safety-lock knob on the blue rotating handle (turn the safety-lock knob in the direction of the arrows). Turn the blue rotating handle following the directional arrow next to label 1 until a stop is felt. 2. Turn the gray safety-lock knob indicated by label 2 on the black telescoping gripper (turn the safety-lock knob in the direction of the arrows). To release the distal bare stent, stabilize the introduction system...

 Open the catalog to page 24
Physician’s-25

Zenith Visceral Zenith Visceral Endovascular Grafts

 Open the catalog to page 25
Physician’s-27

Zenith Fenestrated Zenith* Fenestrated AAA ENDOVASCULAR GRAFT

 Open the catalog to page 27
Physician’s-29

Order Reference Number Part Number Aortic Vessel OD mm Proximal Body Diameter mm Proximal Introducer Body Sheath Length ID/OD Zenith Fenestrated One Proximal Internal Stent 24 mm Diameter G32502 ZFEN-P-1-24-76-R 19-21 24 76 20 (6.7)/7.7 Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details.

 Open the catalog to page 29
Physician’s-30

Proximal Body Grafts One Internal Proximal Stent Zenith Fenestrated ZFEN-P-1-XX-YY-R ZFEN-P-1-(proximal body diameter)-(proximal body length)-R Note: All measurements are in millimeters. The black numbers on the illustrations indicate stent lengths. The red numbers indicate gap lengths. Gap lengths are approximate. Contralateral and ipsilateral iliac legs: Refer to pages 33-39 of this pocket guide for Spiral-Z AAA Iliac Leg Grafts.

 Open the catalog to page 30

All COOK Medical catalogs and technical brochures

  1. One-Tie

    4  Pages

  2. WIRE GUIDES

    36  Pages

  3. Biodesign

    12  Pages

Archived catalogs

  1. LITHO-60

    16  Pages

  2. Litho 100

    16  Pages

  3. HiWire

    2  Pages

  4. EUS 3 Needle

    12  Pages

  5. Beacon Tip

    4  Pages

  6. FISTULA BRUSH

    2  Pages

  7. Fusion ®

    2  Pages

  8. Zenith

    2  Pages

  9. EchoTip®

    2  Pages

  10. Hercules ®

    2  Pages

  11. Biodesign®

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.