Surgical Melker
2Pages

{{requestButtons}}

Catalog excerpts

Surgical Melker - 1

QUICK REFERENCE CARD Seldinger Technique Instructions* Achieve certainty in seconds. 1. Carefully palpate the cricothyroid membrane. Stabilize the cartilage and make a vertical incision along the midline. (Figure 1) 2. Attach the syringe to either needle in the set. Then advance the needle at a 45-degree angle in a caudal direction through the midline incision and into the airway. (Figure 2) 2. 3. After you have accessed the trachea, remove the syringe. If using the catheter introducer needle, remove the syringe and needle, leaving the catheter in place. Then advance the wire guide, flexible end first, into the 3. introducer catheter or the needle. (Figure 3) 4. Once the wire guide is within the trachea, remove the introducer catheter or the needle. (Figure 4) 4. 5. Advance the airway catheter assembly over the wire guide and completely into the trachea. (Figure 5) Remove the dilator and the 5. wire guide simultaneously. 6. Use a syringe to inflate the cuff; an 8-10 mL volume in the cuff will Customer Service yield a cuff diameter of 22-29 mm. EMEA: EDI – www.cookmedical.com/edi.do Distributors: +353 61239240, ssc.distributors@cookmedical.com Austria: +43 179567121, oe.orders@cookmedical.com Belgium: +32 27001633, be.orders@cookmedical.com Denmark: +45 38487607, da.orders@cookmedical.com Finland: +358 972519996, fi.orders@cookmedical.com France: +33 171230269, fr.orders@cookmedical.com Germany: +49 6950072804, de.orders@cookmedical.com Hungary: +36 17779199, hu.orders@cookmedical.com Ireland: +353 61239252, ie.orders@cookmedical.com Italy: +39 0269682853, it.orders@cookmedical.com Netherlands: +31 202013367, nl.orders@cookmedical.com Norway: +47 23162968, no.orders@cookmedical.com Spain: +34 912702691, es.orders@cookmedical.com Sweden: +46 858769468, se.orders@cookmedical.com Switzerland – French: +41 448009609, fr.orders@cookmedical.com Switzerland – Italian: +41 448009609, it.orders@cookmedical.com Switzerland – German: +41 448009609, de.orders@cookmedical.com United Kingdom: +44 2073654183, uk.orders@cookmedical.com 7. Secure the emergency airway catheter with tracheostomy tape. 8. Connect the emergency airway catheter to a ventilation device. www.cookmedical.com * For complete instructions, contraindications, warnings, and precautions, see the Instructions for Use that are included with the product. Americas: EDI – www.cookmedical.com/edi.do Phone: +1 812.339.2235, 800.457.4500, Fax: 800.554.8335 E-mail: orders@cookmedical.com

Open the catalog to page 1
Surgical Melker - 2

MELKER EMERGENCY CUFFED CRICOTHYROTOMY CATHETER SETS MELKER UNIVERSAL EMERGENCY CUFFED CRICOTHYROTOMY CATHETER SET QUICK REFERENCE CARD A recent report recommends that surgical cricothyrotomy be taught alongside the Seldinger technique.* Our products allow you to use either the Seldinger or surgical cricothyrotomy technique to establish h an airway during "cannot intubate, cannot ventilate" scenarios. Surgical Technique Instructions* The universal set provides all the components you need for either the Seldinger or the surgical technique. You choose which technique you want to perform. 1....

Open the catalog to page 2

All COOK Medical catalogs and technical brochures

  1. LITHO-60

    16 Pages

  2. Litho 100

    16 Pages

  3. Physician’s

    92 Pages

  4. HiWire

    2 Pages

  5. EUS 3 Needle

    12 Pages

  6. Beacon Tip

    4 Pages

  7. Fusion ®

    2 Pages

  8. Zenith

    2 Pages

  9. EchoTip®

    2 Pages

  10. Hercules ®

    2 Pages

  11. Biodesign®

    2 Pages

Archived catalogs