Her Option®

Her Option®

Her Option®

Product catalog summary
Overview: The document presents Her Option®, a cryoablation therapy system designed for in-office endometrial ablation procedures. It emphasizes patient comfort, safety, and efficacy, highlighting its ultra-slim 5.5 mm probe and the absence of the need for intravenous sedation.
Specifications: The Her Option® system includes a console (CG-1), a cryoprobe, and a disposable probe (CU-1). The ultra-slim 5.5 mm probe minimizes cervical dilation and avoids uterine distention.
Patient Comfort and Safety: Her Option® provides a natural analgesic effect through sub-zero temperatures, reducing pain and eliminating the need for anesthesia. 95% of patients reported comfort or slight discomfort, with a mean pain score of 1.1 on a scale of 1-10.
Complication Rates: Her Option® boasts the lowest complication rate among endometrial ablation devices, with a rate of 1/3,000, compared to other methods like Microwave (1/630) and NovaSure® (1/1,394).
Patient Outcomes: The system reports high patient satisfaction (89%) and reduced bleeding (92%). It offers short treatment times and high reimbursement rates, ensuring efficiency and control over scheduling.
Company Background: CooperSurgical, the company behind Her Option®, has a history of introducing advanced technology to the Ob/Gyn field, including LEEP and colposcopy. They focus on improving healthcare delivery to women through innovative medical devices.
Contact Information: For more information, visit www.heroption.com or call 800.243.2974.
See more

Catalog excerpts

Her Option®-1

in-office cryoablation therapy Complication Rate Shown Actual Size ^ The Best Choice for In-Office Ultra-Slim 5.5 mm Probe ^ Endometrial Ablation Procedures

 Open the catalog to page 1
Her Option®-2

The Lowest Pain Score Among All Endometrial Ablation Devices No Intravenous Sedation Required Her Option® eliminates the need for anesthesia. Cryotherapy’s sub-zero temperatures provide a natural analgesic effect, reducing pain and maximizing comfort.1 • 95% of patients surveyed said they were comfortable or experienced only slight discomfort during the procedure and 96% would recommend Her Option to a friend2-3 • Patients reported a mean overall pain score of 1.1 during the procedure, a discomfort level on a pain scale of 1 -10 (1 for mild, 10 for severe)4 • Avoids complications from anesthesia...

 Open the catalog to page 2
Her Option®-3

The Only Endometrial Ablation Therapy System Designed for In-Office Use Rate of Reported Complications Nova Sure* The Lowest Complication Rate Among Her Option, featuring cryoablation technology, is proven to be the safest method among all ablation devices. Uterine scarring is minimized.6 • Maximum visibility, accuracy and control minimizes chance of perforations and risk to adjacent tissue7 Serious inter-operative complications are rare8 • Ability for cavity evaluation post ablation9 • Less risk of adhesions in cavity9 For the most up-to-date complication rates, please visit the MAUDE data base...

 Open the catalog to page 3
Her Option®-4

In-Office Ablation is Safe and Effective with Her Option Short Total Treatment Time... From Pre-Procedure to Recovery While other ablation devices boast of short procedure times, it is important to consider the actual time of the complete treatment. When you consider anesthesia, pre-treatment, dilation, hysteroscopy and safety checks, the total treatment time of Her Option compared to any other ablation therapy is considerably shorter. Our shorter treatment time helps to: • Enhance patient comfort • Provide convenience for you and your staff • Open up exam room space Complete Command Over Scheduling...

 Open the catalog to page 4
Her Option®-5

in-office cryoablation therapy Cryoablation Therapy Other methods of ablation were designed and developed as hospital procedures, and were not originally intended for office use. Her Option is different. It has been engineered to be used exclusively in-office as a safe, effective and low-pain alternative to heat and RF energy treatments. Cryoablation's freezing technology will provide you and your patients with effective results.

 Open the catalog to page 5
Her Option®-6

Summary of Warnings, Precautions and Contraindications for the Her Option® Cryoablation Therapy System The Her Option Cryoablation Therapy System is a closed-cycle cryosurgical device intended to ablate the endometrial lining of the uterus in pre-menopausal women with menorrhagia or excessive bleeding due to benign causes for whom childbearing is complete. • The device is contraindicated for patients who are pregnant or who desire to become pregnant in the future, patients with a known or suspected endometrial carcinoma or premalignant change of the endometrium or have an active genital or urinary...

 Open the catalog to page 6

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.