Cementless Total Hip Replacement A universal choice for cementless total hip replacement
Open the catalog to page 1MetaFix™ is based on a clinically proven1,2,3,4,5,6 femoral stem design which was developed in France during the early 1980s by the ARTRO Group, who trained together in Lyon. Typical survivorship rates with stems of this type are: ■■
Open the catalog to page 2Based on a proven design with over 25 years of clinical use
Open the catalog to page 3Today’s patients have increased expectations and place increased demands upon their total hip replacement. The 155μm hydroxyapatite coating and proven stem geometry offer the surgeon and patient confidence in stem stability across multiple indications The evolution of different treatment options has facilitated greater options to treat a broad range of patient indications. The three neck offset options allow the surgeon to restore the patient’s natural biomechanics. All three neck varieties are available in sizes 0-10, offering a total of 33 different stem solutions: The MetaFix stem is...
Open the catalog to page 4Trunnion characteristics An independent test centre electrochemical evaluation showed that the dynamic current which indicates micromotion between the taper and head was below the median reached by stems of the predicate devices7. The MetaFix instrumentation is designed for simplicity and theatre efficiency and includes: ■■ A choice of male/female broach handle connections to suit individual surgeon requirements Lighter weight trays for manoeuvrability Specialised instrumentation platform, designed to suit all surgical approaches, allowing for simple, accurate implantation and reproducible...
Open the catalog to page 5National Joint Registry for England and Wales 2011 Annual Report. Australian National Joint Register 2011 Annual Report. Epinette JA, Geesink RGT. Hydroxyapatite Coasted Hip and Knee Arthroplasty. Expansion Scientifique Francaise. 1995. 2-7046-1470-9. Epinette JA, Manley MT. Fifteen Years of Clinical Experience with Hydroxyapatite Coatings in Joint Arthroplasty. Springer-Verlag. 2004. 2-287-00508-0. Geesink RGT, Manlet MT. Hydroxylapatite Coatings in Orthopaedic Surgery. Raven Press. 1995. 0-7817-0005-1. Hallan G, Lie SA, Furnes O, Engesaeter LB, Vollset SE, Havelin LI. Medium. and long...
Open the catalog to page 6All Corin catalogs and technical brochures
-
Revival™ 100mm
2 Pages
-
Revival™
2 Pages
-
TriFit TS™
2 Pages
-
Evidence base
8 Pages
-
Dynacup™
6 Pages
-
Dual Mobility™
4 Pages
-
Meije Duo™
4 Pages
-
Linea™
4 Pages
-
Dynacup One-C™
4 Pages
-
MiniHip™ - The evidence base
16 Pages
-
MiniHip™ - product overview
12 Pages
-
Trinity™ - surgical technique
16 Pages
-
Trinity - design rationale
12 Pages
-
clinical excellence
6 Pages
-
Revival™
6 Pages
-
Biomimetic Cementless Technology
12 Pages
-
ECiMa™
12 Pages
-
LARS™
6 Pages
-
Solomax™
4 Pages
-
Zenith™
12 Pages
-
Rotaglide+™
12 Pages
-
MetaFix™
12 Pages
-
TriFit TS™
12 Pages
-
Trinity™ - product overview
12 Pages
-
Optimized Positioning System
12 Pages
-
Uniglide™
28 Pages
-
Unity knee surgical technique
24 Pages
-
TriFit TS surgical technique
12 Pages
-
MiniHip™ - surgical technique
12 Pages
-
OPS™
6 Pages
-
Unity KneeTM
16 Pages
-
Hip continuum
6 Pages
-
TriFit TS?
12 Pages
-
LARS ACL
12 Pages
-
LARS
8 Pages
-
Solomax
4 Pages
-
Zenith
12 Pages
-
Uniglide
12 Pages
-
Rotaglide+
12 Pages
-
Cormet - product overview
12 Pages
-
MiniHip - design rationale
16 Pages
-
MiniHip - product overview
12 Pages
-
Trinity
12 Pages