video corpo

Uniglide Unicompartmental Knee System
12Pages

{{requestButtons}}

Catalog excerpts

Uniglide Unicompartmental Knee System - 1

Uniglide™ Unicompartmental Knee Replacement Product overview

Open the catalog to page 1
Uniglide Unicompartmental Knee System - 2

History | Technology | Versatility Uniglide™ is a clinically proven highly congruent, triple radius unicompartmental knee system, offering the surgeon complete flexibility through advanced instrumentation and diverse implant choice. With over 10 years’ successful clinical use of advanced coatings, titanium nitride (TiN) ceramic and Biomimetic Cementless Technology, Uniglide™ offers the surgeon and patient a low wear solution with early, rapid and long-term fixation.

Open the catalog to page 2
Uniglide Unicompartmental Knee System - 3

The unicompartmental knee replacement for any surgical need

Open the catalog to page 3
Uniglide Unicompartmental Knee System - 4

History 20 years’ advancing innovation in unicompartmental knee replacement Development begins The first implantation of AMC Unicondylar Introduction of coating technology, TiN and Biomimetic Cementless Technology Re-launch with advanced MIS instrumentation First implantation using navigation Corin celebrates 20 years of unicompartmental knee replacement

Open the catalog to page 4
Uniglide Unicompartmental Knee System - 5

First implanted in 1991, and with subsequent developments including the introduction of advanced coating technologies and surgical navigation, Uniglide™ has now been successfully clinically used for almost 20 years1.

Open the catalog to page 5
Uniglide Unicompartmental Knee System - 6

Technology Corin is dedicated to the use of advanced technologies to improve implant function and longevity. 10 years of successful cementless clinical use

Open the catalog to page 6
Uniglide Unicompartmental Knee System - 7

gnitaoc TINOB fo ssecorp nevorp dna dehsilbatse-llew a si gnitaoc tinoB amsalp muinatit a ot etahpsohp muiclac fo reyal niht a gniylppa .noitargetni enob lamitpo sevig hcihw reyal deyarps TiN coating Titanium nitride coating is a ceramic layer that is applied to the polished surface to reduce wear and enhance longevity of the implant. The TiN coating has been successfully shown to reduce wear by up to 98%2. taL | laideM | eliboM | dexiF gnitaoc edirtin muinatiT ot deilppa si taht reyal cimarec a si gnitaoc edirtin muinatiT eht ecnahne dna raew ecuder ot ecafrus gniraeb dehsilop eht .tnalpmi...

Open the catalog to page 7
Uniglide Unicompartmental Knee System - 8

Versatility Mobile | Fixed | Cementless | Cemented Uniglide™ provides the greatest choice for both surgeon and patient. Implants are available with or without the TiN and Biomimetic Cementless coatings and are available as a mobile bearing or an all poly fixed option.

Open the catalog to page 8
Uniglide Unicompartmental Knee System - 10

Innovation in implant design Natural kinematics The triple radius geometry of the femoral component allows for a more natural fit and preserves the facet centres. In combination with the deep dished mobile bearing, Uniglide™ is a unicompartmental knee system that provides a more natural kinematic function. Bone conservation The triple radius design of the femoral component also allows for less bone to be removed, meaning any subsequent revision is made easier. Strength and stability The combination of the dual peg and keel design gives greater confidence in the security of the both the...

Open the catalog to page 10
Uniglide Unicompartmental Knee System - 11

Advanced instrumentation Uniglide™ Mk III instrumentation allows for reproducible surgery time after time. Extra-medullary and intra-medullary femoral alignment, multiple tibial preparation options, as well as intra-operative flexibility, make the Uniglide™ an unrivalled choice for unicompartmental knee replacement. | 11

Open the catalog to page 11
Uniglide Unicompartmental Knee System - 12

1. Saxler G, Temmen D, Bontemps G. Medium-term results of AMC-unicompartmental knee arthroplasty. The Knee 2004;11:39-355. 2. Pappas MJ, Makris G, Buechel FF. Titanium nitride ceramic film against Polyethylene. Clin Ortho Rel Res 1995;317:64-70. 3. Schwarz ML, Kowarsch M, Rose SB, Jani L. Histomorphometrical and mechanical evaluation of various surfaces on titanium test bodies placed into femora of the Göttinger minipig. Can a resorbable CaP coating increase osteointegration? 49th Annual Meeting of the Orthopaedic Research Society 2003; Poster. 4. Data on file Corin Group 2009. 5. Becker P,...

Open the catalog to page 12

All Corin catalogs and technical brochures

  1. Revival™

    2 Pages

  2. TriFit TS™

    2 Pages

  3. Dynacup™

    6 Pages

  4. Meije Duo™

    4 Pages

  5. Linea™

    4 Pages

  6. Revival™

    6 Pages

  7. ECiMa™

    12 Pages

  8. LARS™

    6 Pages

  9. Solomax™

    4 Pages

  10. Zenith™

    12 Pages

  11. Rotaglide+™

    12 Pages

  12. MetaFix™

    12 Pages

  13. TriFit TS™

    12 Pages

  14. Uniglide™

    28 Pages

  15. OPS™

    6 Pages

  16. Unity KneeTM

    16 Pages

  17. TriFit TS?

    12 Pages

  18. LARS ACL

    12 Pages

  19. LARS

    8 Pages

  20. Solomax

    4 Pages

  21. Zenith

    12 Pages

  22. Uniglide

    12 Pages

  23. Rotaglide+

    12 Pages

  24. Trinity

    12 Pages