Corning® Synthetic Cell Culture Surfaces
11Pages

{{requestButtons}}

Catalog excerpts

Corning® Synthetic Cell Culture Surfaces - 1

Corning® Synthetic Cell Culture Surfaces Surface treatments for flasks, dishes, and plates for cell culture vessels

Open the catalog to page 1
Corning® Synthetic Cell Culture Surfaces - 2

Corning® Osteo Assay Surface For osteogenesis research Corning Osteo Assay surface is a unique 3-dimensional structure that mimics in vivo bone for in vitro bone cell assays. This inorganic bone biomaterial surface in a multiple well plate is capable of supporting the functional properties of osteogenic cells. The assay surface is m anufactured using a proprietary surface coating technology, which delivers lot-to-lot c onsistency, translating to consistent and reproducible results in bone cell assays. This surface also offers a consistent and defined alternative to preparing dentine or bone...

Open the catalog to page 2
Corning® Synthetic Cell Culture Surfaces - 3

Corning® Ultra-Low Attachment Surface Unique hydrogel surface that inhibits cell attachment The same Ultra-Low Attachment (ULA) surface that you have used on microplates is available on a variety of Corning products. Prevents stem cells from attachmentmediated differentiation The Ultra-Low Attachment surface is a unique, covalently bonded hydrogel surface that is h ydrophilic and neutrally charged. It minimizes cell attachment, protein absorption and e nzyme activation. The surface is noncytotoxic, biologically inert, and nondegradable. The Ultra-Low Attachment surface is designed for: w...

Open the catalog to page 3
Corning® Synthetic Cell Culture Surfaces - 4

Corning® CellBIND® Surface Increase cell growth and yields Corning TC-treated The Corning CellBIND surface enhances cell attachment under challenging conditions, such as reduced-serum or serum-free medium, resulting in higher cell yields. Corning CellBIND Surface Developed by Corning scientists, this technology uses a micro wave plasma process for treating the culture surface. This process improves cell attachment by incorporating significantly more oxygen into the cell culture surface, r endering it more hydrophilic (wettable) and increasing surface stability. Attachment of LNCaP cells....

Open the catalog to page 4
Corning® Synthetic Cell Culture Surfaces - 5

Corning® Primaria™ Surface Improve attachment and growth for primary cells attachment The Corning Primaria surface features a unique mixture of oxygen-containing (negatively charged) and nitrogen-containing (positively charged) functional groups on the polystyrene surface. The surface supports improved attachment, spreading, and differentiation of some cell types that can exhibit poor attachment or limited differentiation potential when cultured on traditional TC surfaces, including neuronal, primary, endothelial, and tumor cells. w Crystal-grade polystyrene modified by proprietary...

Open the catalog to page 5
Corning® Synthetic Cell Culture Surfaces - 6

Corning® PureCoat™ Amine and Carboxyl Surfaces Robust cell culture in reduced serum and/or serum-free media Corning PureCoat Amine (positively charged) and Carboxyl (negatively charged) surfaces provide improved cell attachment, faster cell proliferation, and enhanced recovery post-thaw over standard TC surfaces. These surfaces function with a broad range of primary, transfected, transformed, and fastidious cell types, and have demonstrated utility in serum-reduced or serum-free conditions. w Provide robust and better cell attachment of transfected and transformed cell lines than standard...

Open the catalog to page 6
Corning® Synthetic Cell Culture Surfaces - 7

Corning® PureCoat™ ECM Mimetic Surfaces Synthetic surfaces to mimic natural ECM attachment and functionality Corning PureCoat ECM Mimetic Cultureware is coated with biologically active synthetic animal-free peptides that are covalently linked to a proprietary surface to provide a highly consistent alternative to complex extracellular peptides. The peptides are rationally designed to mimic the cell attachment motifs of native ECM proteins, which promotes optimal cell binding and signaling in a broad range of serum-free, xeno-free, and animal-free media formulations. Corning PureCoat ECM...

Open the catalog to page 7
Corning® Synthetic Cell Culture Surfaces - 8

Corning® Roller Bottles Ideal for a variety of rolling applications, Corning Roller Bottles are made of USP Class VI Polystyrene. They are single-use, sterile, feature laser-etched graduations, and are available in 490 cm2, 850 cm2, 1,700 cm2 pleated, and 1,750 cm2 sizes. Caps are available in solid High Density Polyethylene (HDPE) or vented HDPE with a 0.2 mm micro-porous PTFE membrane. w Treated for optimal cell attachment One piece seamless construction All bottles have printed lot numbers to aid in product traceability Sterility Assurance Level (SAL) of 10-6 Expected Cell Yields and...

Open the catalog to page 8
Corning® Synthetic Cell Culture Surfaces - 9

Stackable Cell Culture Corning® CellSTACK® Culture Chambers w Available in five sizes: - 1-Stack with 636 cm2 cell growth area - 2-Stack with 1,272 cm2 cell growth area - 5-Stack with 3,180 cm2 cell growth area - 10-Stack with 6,360 cm2 cell growth area - 40-Stack with 25,440 cm2 cell growth area Choice of traditional tissue culture treatment, Corning CellBIND® surface for enhanced cell attachment, or Ultra-Low Attachment surface for reduced cell attachment on select CellSTACK products. - Corning CellBIND surface • Great for reducing serum levels • Better attachment increases cell yields -...

Open the catalog to page 9
Corning® Synthetic Cell Culture Surfaces - 10

Corning® CellSTACK® Accessories Corning offers a variety of accessories to simplify handling and reduce contamination risks when processing Corning CellSTACK chambers. Better Filling Corning CellSTACK stacking device (Cat. No. 3331) Optional filling caps allow direct aseptic transfer of media and cells via pumping or gravity feed. Coupling devices are available with or without integrally sealed, chemically resistant, heat-sealable flexible tubing. Optional filling caps with attached hydrophobic membrane filters provide for gas exchange and faster aseptic venting during l iquid transfers....

Open the catalog to page 10
Corning® Synthetic Cell Culture Surfaces - 11

Warranty/Disclaimer: Unless otherwise specified, all products are for research use or general laboratory use only.* Not intended for use in diagnostic or therapeutic procedures. Not for use in humans. These products are not intended to mitigate the presence of microorganisms on surfaces or in the environment, where such organisms can be deleterious to humans or the environment. Corning Life Sciences makes no claims regarding the performance of these products for clinical or diagnostic applications. *For a listing of US medical devices, regulatory classifications or specific information on...

Open the catalog to page 11

All Corning BV catalogs and technical brochures