Product Catalogue 2015
1 /25Pages

Product Catalogue 2015

Product Catalogue 2015
1 /25Pages

Catalog excerpts

Product Catalogue 2015-1

(AC-COCATA) Edition 9 January 15 The Future of Dental Implants Cortex GmbH • Würzburger Str. 5 • 97084 Würzburg • Deutschland • t +49 931 35814430 www.cortex-den

 Open the catalog to page 1
Product Catalogue 2015-2

Surgical Instruments • Surgical Kits basic Prime Premium • Instruments • Stoppers kits Prime Premium • Drills Reference Table CL<=>71T=X The Future of Dental Implants I Cortex GmbH • Wurzburger Str. 5 • 97084 Wurzburg • Deutschland • t +49 931 35814430 www.cortex-dental.com

 Open the catalog to page 2
Product Catalogue 2015-3

d<=>;=5T=X The Future of Dental Implants Cortex Dental Implants Industries Ltd. is a developer, manufacturer and marketer of innovative, high-quality and affordable dental implants, prosthetic products and surgical kits. The company was formed in 2008 by a group of expert clinicians, maxillofacial surgeons and opinion leaders in the field of dental implantology, who joined forces with leading business and marketing professionals to answer the market need for practical, innovative solutions for dental rehabilitation and restoration. Cortex takes pride in being a dynamic, fast-moving company whose...

 Open the catalog to page 3
Product Catalogue 2015-4

Material We use Titanium Alloy Ti 6AI-4V ELI, a material proven to be highly successful in the fabrication of dental implants. Ti 6AI-4V ELI is a dense, strong material that resembles bone. Its mechanical strength (40% stronger than grade 4) allows flexibility in implant design geometry. Ti 6AI-4V ELI is highly resistant to corrosion as it spontaneously and immediately forms a stable, continuous, tightly adherent oxide film upon exposure to oxygen in air or water, which protects the underlying metal from further oxidation and corrosion. Surface Treatment The surface roughness and microgeometry...

 Open the catalog to page 4
Product Catalogue 2015-5

Sterilization Cortex products undergo a severe sterilization procedure including gamma-ray irradiation at a 2.5 M.R. I.D intensity, as required by regulatory bodies. These regulators have granted our implants a 5-year validity period. Primary Stability Implant geometry and surface treatments play a role in the primary fixation and long- term mechanical stability. Surface optimization allows greater bone-implant contact, enhancing the apposition of new bone during the remodeling process. Optimal surface roughness provides ideal conditions for protein absorption and cell attachment. Quality Assurance...

 Open the catalog to page 5
Product Catalogue 2015-6

Cortex Implant Packaging Concept =3 Cl Implant premium set Pre Assembled Implant and • Simple and safe procedure. Surgical Strategies Allows the implantologists to adopt any implantation strategy during the procedure: • Two stages (submerge). • One stage- Metal healing cap. • Plastic healing cap / Immediate loading. • Immediate impression. Direct Mounting of Implant and Abutment (Carrier) • The most sterile way to extract the implant from its case and transfer it to its location. • Time-saving and easy to use transferring system. Cost Effective - 6 Elements in One Packaging • Cover screw....

 Open the catalog to page 6
Product Catalogue 2015-7

Best preservation of bone quantity and improved bone quality LOT/Batch number Expiration date (YYYY-MM) DYNAMIX DYNAMIX DYNAMIX DYNAMIX DYNAMIX DYNAMIX DYNAMIX DYNAMIX DYNAMIX DYNAMIX DYNAMIX DYNAMIX Drilling Sequence SequenseSequenseSoft:Type BoneBoneBone--Type D3, D4D4 Drilling Drilling DrillingDrillingBone BoneBoneSoft-Bone D4D3, D4D4 Drilling Drilling DrillingDrilling BoneD3,D3, BoneD4TypeD4 D4D3, Drilling Sequense SequenseSequenseSoftBoneD4 Type D3, SequenseSequense- Soft SoftSoft-D4 Type - Type DrillingSoft Soft : SequenseTypeD4 D3, D3, Sequense Sequense Type:D4 Type : Drilling Bone : Soft:...

 Open the catalog to page 7
Product Catalogue 2015-8

Best preservation of bone quantity and improved bone quality Best preservation of bone quantity and improved bone quality Soft Tissue • The same prosthetic platform 3.75mm • “Locking elements“- extra resistance for contra prosthetic rotational forces during the rehebalitation. • Enables immediate loading. Cancelous Bone • Thickening threads and wide pitch (gap) provide high bone grip and initial stability • Passive ring allowing biological width adaptation and decreasing crestal stress • Implant top part – four threads: Two threads continuing from the base threads and two new threads. • Extra...

 Open the catalog to page 8
Product Catalogue 2015-9

Ideal bone to implant contact Ideal bone to implant contact Index Premium Package • The same prosthetic platform 3.75mm All clinical situations and all bone types. Following are the majors advantages of the new Classix implant CLASSIX BCSC -0860 CLASSIX CLASSIX CLASSIX CLASSIX CLASSIX CLASSIX CLASSIX CLASSIXBCSC-1060 6.0 CLASSIX BCSC-0660 Optimal Bone Grip & Compression Drilling SequenseSoft SoftSoftSoft BoneType Type D4 Drilling Drilling SequenseSoftSoftD3, D3, -D4 D4 D4 Drilling Drilling : Bone - :Type -Bone- D4 D4 D3, Drilling : : Sequense :Bone Bone -Type D4 Sequense SequenseSoft -D3, Type...

 Open the catalog to page 9
Product Catalogue 2015-10

CLASSIX SATURN Ideal bone to implant contact The ultimate implant for post extraction immediate loadin CL Saturn Dimensions Bone Shifting Platform • All implant prosthetic platform diameters are equal • Unified prosthetic platform is 3.5 mm. • Efficient and cost effective solutions. • Due to the switching platform geometry, the diameter at the abutment connection level of the implant is reduced to the dimention of the abutment and lateralizes the micro-gap. • Better for soft tissue adaptation, reduces bone resorption and reduces crestal stress. Premium Package Prime Package Locking Elements •...

 Open the catalog to page 10
Product Catalogue 2015-11

SATURN SMART 1 PIECE The ultimate implant for post extraction immediate loading Best preservation of bone quantity and improved bone quality The Saturn Smart IPiece Dimensions cl Especially suited for immediate loading after extraction. Saturn’s “wings” provide substantial initial stability, reducing stress distribution at the alveolar cortex and optimize esthetic restoration. Primary stability of the Saturn implant in the empty socket is over 40 Ncm enabling the immediate placement of esthetic temporary crowns. Saturn is also suitable for cases of open and closed sinus grafting. Expanded diameter...

 Open the catalog to page 11

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.