The INNO External Implant system features an external hexagonal connection with hex sizes of 2.7 mm and 3.4 mm, compatible with platforms of diameters Ø4.1 mm and Ø5.1 mm. Implant diameters range from Ø3.5 mm to Ø6.0 mm, with lengths available from 7 mm to 14 mm. The system includes various components designed for fixture placement, impression taking, and prosthetic procedures.

1. Implant Specifications

  • Hex Connection: External hex 2.7 mm or 3.4 mm.
  • Platform Diameters: Ø4.1 mm (for fixture diameters Ø3.5, Ø4.0, Ø4.5) and Ø5.1 mm (for fixture diameters Ø5.0, Ø6.0).
  • Implant Diameters: Ø3.5, Ø4.0, Ø4.5, Ø5.0, Ø6.0 mm.
  • Implant Lengths: 7, 8, 10, 12, 14 mm.
  • Surface Treatment: SLA-SH® for enhanced osseointegration.

2. Packaging and Mounting

  • Pre-mounted implants include 1 fixture, 1 mount, and 1 mount screw per package.
  • Mounting and cover screws are tightened using a 1.2 Hex Driver with a torque of 5-10 N.cm.

3. Healing and Prosthetic Components

  • Healing Abutments: Used for gingival contour remodeling during soft tissue healing; selected based on gingival height and abutment type; tightened with 1.2 Hex Driver at 5-10 N.cm torque.
  • Prosthetic Procedures: Three main prosthetic procedures are outlined, involving cemented abutments, UCLA abutments (plastic and Meta G), angulated abutments, shoulder abutments, and ball abutments.

3.1 Cemented Abutments

  • Available in various diameters and lengths, compatible with hex and non-hex connections.
  • Used for cement-retained and screw-cement retained prostheses.
  • Tightening torque: 20 N.cm.

3.2 UCLA Abutments

  • Plastic UCLA Abutment: PMMA material, lower connection accuracy, used during wax pattern fabrication; tightened lightly by finger during fabrication and 30 N.cm after casting.
  • Meta G UCLA Abutment: CCM alloy core for precise connection, suitable for screw-cement or screw-retained prostheses; tightened at 30 N.cm.

3.3 Angulated Abutments

  • Available in 15° and 25° angulations for anterior esthetic zone solutions.
  • Compatible with hex and non-hex connections.
  • Tightening torque: 30 N.cm.

3.4 Shoulder Abutments

  • Designed for cement-retained prostheses with dual anti-rotation grip to prevent screw loosening.
  • Includes shoulder abutment caps for gingival protection during healing and as temporary prosthesis sub-structure.
  • Tightening torque: 30 N.cm.

3.5 Ball Abutments

  • Used for implant-supported overdenture prostheses.
  • Includes ball inner caps with retention forces of 10N (red), 15N (orange), and 20N (green), block-out spacers, and outer caps.
  • Tightening torque: 30 N.cm.
  • Direct impression technique is used.

4. Impression Components

  • Fixture Level Impression: Transfer posts and pick-up squared impression copings are used for closed and open tray impressions respectively.
  • Tightening torque for impression components: 12-15 N.cm.
  • Shoulder impression caps and positioning cylinders are used for abutment level impressions.

5. Torque and Tools

  • All screws and abutments are tightened using a 1.2 Hex Driver and Torque Wrench.
  • Tightening torque values vary by component: 5-10 N.cm for cover screws and mounts, 12-15 N.cm for impression components, 20-30 N.cm for abutments.
  • Specialized drivers such as Ball Driver and I&R Driver are used for ball abutment components.

6. Additional Notes

  • Components are designed for interchangeability with external hexagonal fixtures.
  • Packaging units typically include the component plus necessary screws or pins.
  • System supports multiple prosthetic workflows to accommodate various clinical needs.

Summary: The INNO External Implant system is a comprehensive dental implant solution featuring external hex connections with multiple platform sizes and implant dimensions. It includes a wide range of prosthetic components such as cemented, UCLA, angulated, shoulder, and ball abutments, each with specific indications and torque requirements. Impression components and specialized tools support accurate prosthetic workflows. The system emphasizes modularity, precision, and clinical versatility for implant-supported restorations.

See more

Catalog excerpts

INNO External Implant-2

INNO EXTERNAL IMPLANT (Ext.) System Flow 자기는 읽었는데 답없을때보면 그럴때인가부네 Fixture Level Impression Pick-up Squared Impression Coping Transfer Post Plastic UCLA Shoulder Positioning Cylinder Abutment Level Impression

 Open the catalog to page 2
INNO External Implant-3

INNO External Implant (Ext.) * Diameter Length > Packing unit :1 Fixture + 1 Mount + 1 Mount Screw. External Fixture Surface Treatment : SLA-SH® > Interchangeable with external hexagonal fixture. > External hex connection (Hex 2.7 / 3.4). * Diameter Length * Diameter Length Type body External Taper Surface Treatment Mount Pre-Mount SLA INNO Fixture Code

 Open the catalog to page 3
INNO External Implant-4

Diameter Length Component Selection Guide for Cemented & UCLA Abutment > Packing unit : 1 Mount + 1 Mount Screw. > Tightened with the 1.2 Hex Driver. > Tightening torque force : 5~10 N.cm. Abutment Screw Cover Screw Diameter Height Angulated Abutment Temporary Abutment Meta G UCLA Abutment Plastic UCLA Abutment Cemented Abutment > Packing unit : 1 Cover Screw. > To seal the conical interface of fixture. > Tightened with the 1.2 Hex Driver. > Tightening torque force : 5~10 N.cm. Replica Healing Abutment Diameter Length > Packing unit : 1 Healing Abutment. > For remodeling gingival contour during...

 Open the catalog to page 4
INNO External Implant-5

Cemented Abutment Meta G UCLA Abutment > Packing unit : 1 Meta G UCLA Abutment + 1 Abutment Screw. > For Screw-Cement or Screw Retained Prosthesis. > Modification to angulated abutment, customized abutment and telescopic abutment. > CCM alloy core for precise connection. > Cast with non-precious metal or gold alloy. > Connected with the Abutment Screw. > Tightened with the 1.2 Hex Driver and Torque Wrench. > Tightening torque force : 30 N.cm. > Fixture level impression. Type[Hex] Platform [Fixture Dia.] > Packing unit : 1 Cemented Abutment + 1 Abutment Screw. > Tightened with the 1.2 Hex Driver...

 Open the catalog to page 5
INNO External Implant-6

Replica Type[Hex] Prosthetic Procedure II Component Selection Guide for Shoulder Abutment > Packing unit : 1 Replica. > Mimicking of conical interface of fixture. > Analog of fixture for working cast. Pick-up Squared Impression Coping D Shoulder Positioning Cylinder > Packing unit : 1 Pick-up Squared Impression Coping + 1 Guide Pin. > Connected with the Guide Pin (Regular : UHR115 / Wide : UHW115). > For Open Tray Impression. > Tightened with the 1.2 Hex Driver and Torque Wrench. > Tightening torque force: 12~15 N.cm. Shoulder Abutment Cap Transfer Post Shoulder Abutment > Packing unit : 1 Transfer...

 Open the catalog to page 6
INNO External Implant-7

Shoulder Abutment Shoulder Impression Cap Type[Hex] Shoulder Abutment Diameter Diameter Height > Packing unit : 1 Shoulder Impression Cap. > Connected with the Shoulder Positioning Cylinder. > Confirm locking with abutment by rotation of clockwise and anti-clockwise direction. > Packing unit : 1 Shoulder Abutment. > For Cement Retained Prosthesis. > Dual anti-rotation grip for prevention of screw loosening. > Integrated with screw and abutment. > Tightened with the Shoulder Driver. > Tightening torque force : 30 N.cm. > Abutment level impression : Impression cap in platform Ø4.1 fixture and direct...

 Open the catalog to page 7
INNO External Implant-8

Ball Abutment Block-out Spacer Component Selection Guide for Ball Abutment Orange : 15N Block-out Spacer > Packing unit : 1 Ball Abutment + 3 Inner Caps (1 per each color) + 1 Block-out Spacer + 1 Outer Cap. > For Implant Supported Over-denture Prosthesis. > Tightened with the Ball Driver and Torque Wrench. > Tightening torque force : 30 N.cm. > Direct impression. Ball Abutment Diameter Height > Packing unit : 2 Outer Caps. Ball Inner Cap Block-out Spacer > Packing unit : 2 Block-out Spacers + 6 Inner Caps (2 per each color). > Retention force : Red 10N, Orange 15N & Green 20N. Ball Analog Diameter...

 Open the catalog to page 8
INNO External Implant-9

Cowellmedi Co.,Ltd Floor 6, Blue Fin Tower, 42, Seochojungang-ro,Seocho-gu, Seoul, Korea Tel. +82-2-3453-5085 Fax. +82-2-3453-5086 E-mail. [email protected] Cowellmedi USA INC 218 Trianon LN Villanova PA 19085-1442 USA Tel. 1-623-939-1344 Fax. 1-623-939-1472 Cowell R&D Institute 48, Hakgam-daero 221beon-gil, Sasang-gu, Busan, 46986, Korea Tel. +82-51-314-2028 Fax. +82-51-314-2026

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.