Catalog excerpts

INNO SUBMERGED IMPLANT (Sub.) System Flow Abutment Fixture Level Impression Easy Temporary Plastic UCLA Bite Impression Coping Pick-up Impression Coping Multi Pick-up Impression Coping Multi Transfer Post Lock Pick-up Impression Coping Transfer Post Multi Meta G ULCA Cylinder Multi Plastic UCLA Cylinder Multi Titanium Cylinder Multi Polishing Protector Lock Meta G UCLA Cylinder Lock Titanium Cylinder Absolute Plastic Coping Abutment Level Impression Direct Impression Sonator Impression Coping Sonator Analog Ball Analog
Open the catalog to page 2
INNO Submerged Implant No-Mount Diameter Length Submerged Fixture Surface Treatment : SLA-SH® > Packing unit : 1 Fixture + 1 Cover Screw. > Interchangeable with hexagonal morse tapered fixture > Internal hex connection (Taper 11°/ Hex 2.5) Diameter Length Type body Diameter Length Surface Treatment Mount Submerged Taper Ø4.0 10mm SLA Pre-Mount Type body Diameter Length Surface Treatment Mount Submerged Taper Ø4.0 10mm SLA No-Mount INNO Fixture Code INNO-SUBMERGED IMPLA
Open the catalog to page 3
Pre-Mount Diameter Length INNO Submerged Short Implant > Packing unit : 1 Fixture + 1 Cover Screw + 1 Mount. Ø3.5 8 Submerged Short Fixture Surface Treatment : SLA-SH® Diameter Length > Interchangeable with Hexagonal Morse Tapered Fixture. > Internal hex connection (Taper 11°/ Hex 2.5). Diameter Length Diameter Length Packing Unit : 1 Fixture + 1 Cover Screw + 1 Mount. Diameter Length Diameter Length Diameter Length
Open the catalog to page 4
Fixture Mount Components Selection Guide for Cemented and UCLA Abutment > Packing unit : 1 Mount + 1 Mount Screw. > Tightened with the 1.2 Hex Driver. > Tightening torque force : 5~10 N.cm. Abutment Screw Cover Screw Diameter Length > Packing unit : 1 Cover Screw. > To seal the conical interface of fixture. > The longer Cover Screw for deeply inserted fixture. > Tightened with the 1.2 Hex Driver. > Tightening torque force : 5~10 N.cm. *Extra Product Cemented Abutment Angulated Abutment Beauty-up™ Abutment Milling Abutment Diameter Cuff Diameter Cuff Plastic UCLA Abutment Meta G UCLA...
Open the catalog to page 5
Cemented Abutment Beauty-up™ Abutment Angulated Screw Ratchet Drive D Type Diameter(Angle) > Packing unit : 1 Beauty-up™ Abutment > Stable to internal slip or fracture due to wide contact area of the Angulated Driver and the dedicated Stargrip Abutment Screw. Diameter Length > Packing unit : 1 Milling Abutment + 1 Abutment Screw. > For Screw-Cement or Cement Retained Prosthesis. > Block abutment for customized contouring. > Gold color for more translucent restoration. > Connected with the Abutment Screw (2SSHR100). > Tightened with the 1.2 Hex Driver and Torque Wrench. > Tightening torque...
Open the catalog to page 6
Temporary Abutment Abutment Screw Meta G UCLA Abutment > Packing unit : 1 Abutment Screw. > 2SSHR100 : Hybrid Block / Scanbody / Angulated / Milling / Temporary / Meta G UCLA / Plastic UCLA Abutment. > 2SSHR200 : Hybrid S & L Ti-Base / Cemented / Easy Temporary Abutment. > Tightened with the 1.2 Hex Driver and Torque Wrench. > Packing unit : 1 Temporary Abutment + 1 Abutment Screw. > For Screw-Cement Retained Prosthesis. > For provisional restoration. > Connected with the Abutment Screw (2SSHR100). > Tightened with the 1.2 Hex Driver and Torque Wrench. > Tightening torque force : 20 N.cm. >...
Open the catalog to page 7
Bite Impression Coping Type L Component Selection Guide for Multi S&A Abutment > Packing unit : 1 Bite Impression Coping (Inbuilt Guide Pin). > Designed to simultaneously take bite and impression. > For Closed Tray Impression (Bite Impression). > Tightened with the 1.2 Hex Driver and Torque Wrench. Multi Polishing Protector Multi Cylinder Screw Pick-up Impression Coping Type (Short) (Short) Multi Plastic UCLA Cylinder > Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin. > For open tray impression. (Long) > Connected with the Guide Pin (2SISR001SS / 2SISR001SL). > Tightened with the...
Open the catalog to page 8
Multi S & A Abutment Diameter Diameter Height > Packing unit : 1 Multi Protection Cap. > Protection from cheek and tongue for gingival healing period. > Gingival retraction for prosthodontic margin of abutment. > Alternative usage for sub-structure of temporary prosthesis. > Packing unit : 1 Multi S Abutment. > For Screw-Retained Prosthesis. > Titanium base for the cylinders. > Gold color for more translucent restoration. > Integrated with screw and abutment. > Library available for EXOCAD®, 3Shape® & Others. > Use the S Holder for more stable position. > Tightened with the S Machine & S...
Open the catalog to page 9
Multi Titanium Cylinder Multi S & A Abutment Diameter Diameter Length Multi Plastic UCLA Cylinder 1.2 Hex. Diameter Cuff > Packing unit : 1 Multi Plastic UCLA Cylinder + 1 Multi Cylinder Screw. > For Screw, Cement or Screw-Cement Retained Prosthesis. > Same purpose of use as the Meta G UCLA Cylinder but low accuracy of connection. > PMMA material. > Connected with the Multi Cylinder Screw (2SMCS100). > Tightened with the 1.2 Hex Driver and Torque Wrench. > Tightening torque force : 20 N.cm. > Packing unit : 1 Multi Titanium Cylinder + 1 Multi Cylinder Screw. > For Screw, Cement or...
Open the catalog to page 10
Multi Holder Component Selection Guide for Lock Abutment > Packing unit: 1 Multi S Holder. > To position the Multi S Abutment more stably. Lock Cylinder Screw > Packing unit: 1 Multi A Holder. > To position the Multi A Abutment more stably. Lock Meta G UCLA Cylinder Connect the Multi A Holder with the Multi A Abutment with its Abutment Screw in it and match the direction of holes of the abutment and the holder. Hold the handle of the Multi A Holder and bend it according to the placement position in the oral cavity. Connect the assembled body with the fixture. Tighten the Multi Abutment with...
Open the catalog to page 11
Diameter Length Lock Abutment Diameter > Packing unit : 1 Lock Abutment. > For Screw-Retained Prosthesis. > Titanium base for cylinder. > Gold color for more translucent restoration. > Integrated with screw and abutment. > Tightened with the Lock Ratchet Driver and > Tightening torque force : 30 N.cm. > Abutment level impression. > Packing unit : 1 Lock Lab Analog. > Replacement of abutment shape in working cast. > Tightened with the 1.2 Hex Driver and Torque Wrench. Torque Wrench. Lock Meta G UCLA Cylinder Lock Abutment Diameter > Packing unit : 1 Lock Protection Cap. > Protection from...
Open the catalog to page 12All Cowellmedi catalogs and technical brochures
-
COWELL® Implant Solution v.29
137 Pages
-
InnoGenic™ Wifi-Mesh
26 Pages
-
Diaderm® M
3 Pages
-
MEGA DERM™ Plus
3 Pages
-
DIABONE
3 Pages
-
INNO OSS & INNO OSS Allo
3 Pages
-
INNO-CaP
3 Pages
-
COWELL® BMP
6 Pages
-
COWELL® Regenerative Solution
13 Pages
-
InnoGenic™ Bone Carrier
5 Pages
-
Volume-up™ Guide System
4 Pages
-
AO4 Surgical Stent
3 Pages
-
Direct Surgical Guide Kit
7 Pages
-
Atraumatic Extraction Kit
6 Pages
-
COWELL® BMP Trephine Kit
4 Pages
-
InnoGenic™ GBR Kit
7 Pages
-
Sinus Lift Kit
5 Pages
-
COWELL® Expert Instruments
33 Pages
-
Digital Prosthesis (InnoFit)
13 Pages
-
Digital Prosthesis (SFIT)
14 Pages
-
InnoFit® Lodestar Kit
7 Pages
-
InnoFit® Lodestar Plus Kit
11 Pages
-
COWELL® Digital Products
39 Pages
-
Surgical Kit
11 Pages
-
Bite Impression Coping Catalog
10 Pages
-
SONATOR™ 80’s
16 Pages
-
Multi S & A Abutment
20 Pages
-
Beauty-up™ Abutment
31 Pages
-
Ball Abutment System
15 Pages
-
Mini Plus® Implant
5 Pages
-
INNO External Implant
9 Pages
-
INNO Internal Impant
12 Pages
-
INNO Submerged Narrow Implant
10 Pages
-
COWELL® Implant System
66 Pages