1. Catalogs
  2. Criticare Systems
  3. Multi-parameter monitor 506DN eQuality - EN

Multi-parameter monitor 506DN eQuality - EN
1 /2Pages

Multi-parameter monitor 506DN eQuality - EN

Multi-parameter monitor 506DN eQuality - EN
1 /2Pages

Catalog excerpts

Multi-parameter monitor 506DN eQuality - EN-1

Vital Signs Monitoring VitalCare Series Patient Monitors ™ MULTIPLE CONFIGURATIONS I BATTERY MANAGEMENT I COST EFFECTIVE ™ Proprietary ComfortCuff NIBP, pulse oximetry and predictive temperature in one compact, easily transported monitor. Ideal for spot-checks or continuous vital signs monitoring. Features ™ Proprietary ComfortCuff NIBP measures on inflation for faster, more comfortable readings. ™ Choice of Criticare’s DOX digital SpO2 or Nellcor OxiMax™ SpO2 technology. Audible and visual alarms are adjustable; providing instant notification in the manner you need them. Optional FILAC FasTemp™ or Alaris TurboTemp™ predictive temperature for quick, accurate measurements. Optional internal printer for on-demand, automatic interval, trends or multi-patient reports. Spot-check or continuously monitor three critical parameters - on neonates to adults - with a single monitor. Designed to travel everywhere you do, the VitalCare™ Series of patient monitors with integrated carry handle attach quickly and easily to IV pole mounts or rollstands. Available in multiple configurations - with choice of Criticare or Nellcor oximetry - these VitalCare™ monitors provide maximum versatility and cost-effectiveness. Smart battery management allows up to 100 NIBP measurements on a single charging. With a compact design that is easily set-up for spot-checks or continuous monitoring, the VitalCare™ Series patient monitors adapt readily to hospital, clinical and transport requirements.

 Open the catalog to page 1
Multi-parameter monitor 506DN eQuality - EN-2

VitalCare Series Patient Monitors TM Technical Specifications NIBP (Non-Invasive Blood Pressure) Technique: Oscillometric during inflation Measurement Cycle: < 40 sec. typical Automatic Measurement Cycles (Selectable): 1 to 60 minute; 2 to 4 hour; STAT STAT Mode: 5 minutes of continuous readings Inflation Pressure Range: Adult: 30 to 300 mmHg Pediatric: 30 to 150 mmHg Neonate: 20 to 150 mmHg Resolution: 1 mmHg Transducer Accuracy: ±2 mmHg or ±2% of reading, whichever is greater over full range Clinical Accuracy: SP-10:2002 Pulse Oximetry Range: Resolution: Accuracy (DOX only): TM TM Accuracy...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.