ACTIVE STABILIZATION®
8Pages

{{requestButtons}}

Catalog excerpts

ACTIVE STABILIZATION® - 2

OVERVIEW A C T I V E S T A B I L I Z A T I O N® The Active Stabilization® System is the only hybrid plating system to replace static compression with dynamic continuous compression. It is designed to address a full spectrum of foot & ankle procedures. Bending & Rotational Stability P R O D U C T F E AT U R E S Two distinct plate options Low profile anatomic plate design Ability to reposition intraoperatively Active gap recovery 3x more effective at maintaining compression than a traditional plate and cross screw* Sterile Instrumentation with EcoSMART® Service Continuous Compression Active...

Open the catalog to page 2
ACTIVE STABILIZATION® - 3

T E S T I N G DATA GAP RECOVERY The Active Stabilization® system the plate with no clip did not recover fully. presented full gap recovery, while GAP AFTER LOADING WITH NO CLIP GAP AFTER LOADING WITH CLIP The Active Stabilization® system has I N S T R U M E N TAT I O N The Active Stabilization® MPJ Implant COMPETITIVE PLATE + CROSS SCREW higher rotational stability compared to a plate and cross screw. Active Stabilization® 4-Hole Plate + Clip Drill Guide Cone Reamer system comes with sterile packed stainless steel instrumentation. Inserters are pre-loaded with implants for each surgery. Cup...

Open the catalog to page 3
ACTIVE STABILIZATION® - 4

Standard & Short Plate STANDARD PLATES PART NUMBER CLIP SIZE OVERALL LENGTH THICKNESS RIGHT/LEFT Right Left Right Left Right Left SCREWS Non-locking & locking

Open the catalog to page 4
ACTIVE STABILIZATION® - 5

INSTRUMENTS INCLUDED IN EACH KIT Instrumentation is packaged in sterile kits for efficiency and convenience. After surgery, the instrumentation is returned to CrossRoads® via the EcoSMART® Instrument Recovery Service providing a significant cost savings over typical disposable or reusable instrument kits. CLIPS • 1 each, (18x18x18 Kit) • 1 each, (18x14x14 Kit) • 2 each Single Pack, (18x18x18,18x14x14) PLATES • MPJ Standard, 2 each, 0° (left & right) • MPJ Standard, 2 each, 5° (left & right) • MPJ Standard, 1 each, 10° (left & right) • MPJ Short, 2 each, 0° (universal) • MPJ Short, 2 each,...

Open the catalog to page 5
ACTIVE STABILIZATION® - 6

SURGICAL TECHNIQUE STEP 01 Metatarsal Preparation Insert a 1.6mm/.062” guidewire in the central aspect of the metatarsal. Place the metatarsal reamer over the wire and begin to ream. Reamer should be spinning prior to touching bone. Remove all articular cartilage exposing bleeding bone. MPJ STANDARD Note: a small drill bit or k-wire may be used to fenestrate the surface after reaming. STEP 02 Phalanx Preparation Insert a 1.6mm/.062” guidewire in the central aspect of the phalanx. Place the phalangeal reamer over the wire and begin to ream. Reamer should be spinning prior to touching bone....

Open the catalog to page 6
ACTIVE STABILIZATION® - 7

STEP 04 Clip Preparation Use provided instruments to prepare for implantation of the DynaFORCE® clip. STEP 05 Clip Placement Implant the DynaFORCE® clip through the plate. Rotate the knob counterclockwise until pressure is released, then rotate the inserter counterclockwise until the clip releases. Note: A tamp is available if needed. STEP 06 Screw Placement Drill and prepare for screws beginning with distal holes first. Non-Locking screws are recommended, unless bone quality is poor. If locking screws are used, ensure plate is firmly held to the bone on the opposite end prior to fully...

Open the catalog to page 7
ACTIVE STABILIZATION® - 8

■ ■ CrossRoads sUssi H Extremity Systems 6055 Primacy Parkway, Suite 140, Memphis, Tennessee 38119 (901) 221-8406 | info@crextremity.com | crextremity.com

Open the catalog to page 8