Hybrid Implant System

Hybrid Implant System

Hybrid Implant System

Product catalog summary
Overview
The DynaFORCE® Active Stabilization™ System is a pioneering hybrid implant system designed for corrective procedures in the rearfoot, midfoot, and forefoot. It combines plate stability with active compression through clips, offering enhanced stabilization and compression.

Product Features
  • Low Profile Implants
  • Intraoperative Repositioning Capability
  • Full Gap Recovery and Rotational Stability
  • Sterile Instrumentation with EcoSMART® Service
  • Active Stabilization™ for Bending & Rotational Stability
  • Continuous Compression & Active Gap Recovery

Rotational Stability
The system provides superior torsional stability compared to competitors, ensuring less gapping and full gap recovery.

Testing Data
Comparative data shows the DynaFORCE® system outperforms competitive systems in terms of initial gap with load and gap with no load, demonstrating its effectiveness in maintaining stability.

Surgical Technique
  1. Use a template to confirm proper plate size.
  2. Secure the plate with temporary holding wires.
  3. Prepare for the DynaFORCE® clip using provided instruments.
  4. Implant the appropriate clip and release it using the inserter.
  5. Drill and prepare for screws, with non-locking screws recommended.

Instrumentation
Each kit includes sterile instruments for efficiency and cost savings, with a recovery service for post-surgery returns.
  • Driver Handle
  • Plate Bender
  • Reamers
  • Depth Gauge Probe
  • Driver Bits
  • Fixation Pins
  • Drill Guides

Plate Specifications
Various plate models are available, each with specific dimensions and compatible clip sizes. All plates use MotoBAND CP locking/non-locking screws.

Contact Information
For more details, contact CrossRoads® at their Memphis office or visit their website.
See more

Catalog excerpts

Hybrid Implant System-1

Hybrid Implant System ACTIVE STABILIZATION" :ents Pend

 Open the catalog to page 1
Hybrid Implant System-2

OVERVIEW AC TIVE STABILIZ ATION ™ The DynaFORCE® Active Stabilization™ System is the first to offer a hybrid implant system designed to address the most common rearfoot, midfoot and forefoot corrective procedures by combining plate stability with active compression of our clips. Bending & Rotational Stability Continuous Compression & Active Gap Recovery Active Stabilization™ PRODUC T FEATURES Low Profile Implants Ability to Reposition Intraoperatively Full Gap Recovery and Rotational Stability Sterile Instrumentation with EcoSMART® Service T/N Fusions simplified with Active Stabiliza

 Open the catalog to page 2
Hybrid Implant System-3

T E S T I N G DATA GAP RECOVERY The DynaFORCE® Active Stabilization™ system presented less gapping and leading competitors. INITIAL GAP WITH LOAD full gap recovery compared to ROTATIONAL STABILITY DynaFORCE® 4-Hole Plate + Clip The DynaFORCE® Active Stabilization™ systems have higher torsional stability compared to competitive systems. COMPETITIVE PLATE + 4.0 LAG SCREW DYNAFORCE 4-HOLE PLATE + CLIP DYNAFORCE Z-PLATE + CLIP

 Open the catalog to page 3
Hybrid Implant System-4

SURGICAL TECHNIQUE STEP Use template to confirm proper plate size. Place temporary holding wires to secure plate. Use provided instruments to prep for the DynaFORCE® clip. 18mm DynaFORCE® Clip through the plate. Rotate the knob counterclockwise until pressure is released, then rotate the inserter counterclockwise until the clip releases. Note: A tamp is available if needed. Drill and prep for screws. Non-locking

 Open the catalog to page 4
Hybrid Implant System-5

INSTRUMENTS INCLUDED IN EACH KIT Instrumentation is packaged in sterile kits for efficiency and convenience. After surgery, the instrumentation is returned to CrossRoads® via the EcoSMART® Instrument Recovery Service providing a significant cost savings over typical disposable instrument kits. E Depth Gauge Probe H Locking Drill Guide (2) I Non-Locking Drill Guide

 Open the catalog to page 5
Hybrid Implant System-6

Z-ALPHA PLATE Z-BETA PLATE Part Number Acceptable Clip Size(s) Slot Length / Clip Size Overall Length(s) Thickness Part Number Acceptable Clip Size(s) Slot Length / Clip Size Overall Length(s) Thickness 5-HOLE PLATE 4-HOLE PLATE Part Number Acceptable Clip Size(s) Slot Length / Clip Size Overall Length(s) Thickness Part Number Acceptable Clip Size(s) Slot Length / Clip Size Overall Length(s) Thickness * Screw hole with compression slot only accepts non-locking screw. ** All DynaFORCE© plates use MotoBAND CP locking/non-locking screws ■■CrossRoads H Extremity Systems 6055 Primacy Parkway, Suite...

 Open the catalog to page 6

All CrossRoads Extremity Systems catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.