Iceberg Cryonick Roller

Iceberg Cryonick Roller
1 / 34 PagesView full catalog

Iceberg Cryonick Roller

Product catalog summary
Introduction
The user manual for the Iceberg Cryonick Roller provides detailed guidance on its operation, technical specifications, and safety measures. It stresses the importance of following safety protocols, particularly regarding electrical safety and the handling of liquid nitrogen. The manual is crucial for safe and effective use and must accompany the device if resold or relocated.

Purpose and Description
The Iceberg Cryonick Roller is designed for aesthetic purposes, targeting skin and adipose tissues through temperature variations and mechanical manipulation. It combines hot and cold therapies to enhance skin elasticity, break down fat cells, and facilitate lymphatic drainage, applicable in cosmetology, fitness, and medical spas.

Technical Scheme and Operation
The device features a 10” touchscreen and uses antifreeze as a coolant. It includes a thermal handle with a heat exchanger and a lymphatic massage roll handle driven by an electric motor.

Description of Operation
The main unit circulates coolant through a heat exchanger and radiator system. The thermal handle manages heat exchange using a Peltier element, while the massage handle is operated by an electric motor with controls for speed and direction.

Dimensions
The manual details the dimensions of the Iceberg Cryonick Roller and its Mini version.

Operation Check
Pre-start checks ensure the integrity of cables, pipes, and electrical components. The general status involves connecting the device to the network and verifying its operational status.

Operation Modes and Maintenance
The device has heat, cool, and combined modes, with maintenance procedures outlined. It should be disconnected if idle for long periods, and a brief check should be performed before regular use.

Menu and Treatment Operation
The manual guides users on navigating the device menu and conducting treatments.

Troubleshooting and Solutions
Solutions for common operational issues are provided.

Safety
Emphasizes the importance of following safety guidelines to prevent accidents and injuries.

Other Terms of Operation and Maintenance
Includes additional operational guidelines and maintenance tips.

Technical Specifications
Lists voltage, power consumption, and other technical details for both European and American versions.

Warnings and Cautions
Highlights critical safety warnings, including electrical hazards, handling precautions, and operational guidelines to prevent damage and ensure user safety.

Coolant Filling Procedure
Instructions include disconnecting the device before filling, checking for leaks, and inspecting for unusual noises.

Device Status Check
Involves testing the handling handle and inspecting the massage handle for smooth operation.

Safety and Troubleshooting
Users should avoid placing the device near heat sources, use only recommended coolants, and ensure the device is free from spills before operation.

Environmental and Storage Considerations
The device should be stored in a dry place at temperatures between +15°C and +35°C, with regular cleaning and maintenance.

Contraindications and User Questionnaire
Users must ensure they have no contraindications such as severe arteriosclerosis or untreated wounds and complete a questionnaire regarding medical conditions.

User Declaration
Users must affirm they have answered health questions truthfully and acknowledge the risks involved in using the device.

Waiver Form for Commercial Use
Clients acknowledge the studio is not a medical facility and accept risks associated with participation, agreeing not to hold the studio liable for any damages or injuries.

Manufacturer Liability
The manufacturer is not liable for injuries or damages resulting from the use of the equipment. Users must maintain equipment and acknowledge risks such as electric shock and skin burns.

Safety Suggestions
Users should remove metal objects and avoid using creams before sessions. Equipment must be disinfected after each use.

Manufacturer Label and Warranty
The machine's label includes important information such as the manufacturer's name, model, and warnings. The warranty covers 12 months from commissioning or 2,000 sessions, with exclusions for unauthorized repairs and improper use.
See more

Catalog excerpts

Iceberg Cryonick Roller-1

Iceberg i Cryonick ^ Roller Roller Mini ELIMMING AND BODY CONTOURING AESTHETIC

 Open the catalog to page 1
Iceberg Cryonick Roller-2

1. PURPOSE AND BRIEF DESCRIPTION OF ICEBERG CRYONICK ROLLER DEVICE 2. Technical scheme and operation 2.1 Technical scheme of whole device 2.2 Thermal handle 2.3 Lymphatic massage roll handle =3. DESCRIPTION OF OPERATION 3.3 Massage handle M. DIMENSIONS OF DEVICE 4.1 Iceberg Cryonick Roller Mini 4.2 Iceberg Cryonick Roller B. OPERATION CHECK 5.2 General status of device B. OPERATION MODES AND MAINTENANCE OF THE DEVICE 7. MENU AND TREATMENT OPERATION S. POSSIBLE TROUBLESHOOTING AND SOLUTIONS 9. SAFETY lO.OTHER TERMS OF OPERATION AND MAINTENANCE

 Open the catalog to page 2
Iceberg Cryonick Roller-3

Introduction The present Operation Manual contains the description of the Iceberg Cryonick Roller device (hereinafter eferred to as ‘Equipment’), the principles of its functioning, its technical characteristics and the user manual. While mounting and operating the Equipment the users are required to follow all electric safety rules and safety requirements for handling liquid nitrogen. Attention !!!This User Manual is an integral part of equipment operation and customer needs to review start operate equipment! Please read this manual carefully before operating the equipment . Here you can find...

 Open the catalog to page 3
Iceberg Cryonick Roller-4

By buying equipment from Manufacturer or any distributor’s companies, Customer (Owner of equipment) agrees by default to accept next rules and liabilities: by the execution of purchase agreement of equipment, an owner of Equipment accepts and assumes full responsibility for any and all injuries, damages (both economic and non2 economic), and losses of any type, which may occur to owner of Equipment or their guests. Owners of Equipment hold solely responsible for safety and well being of their guest and themselves. Owner of Equipment MUST provide SUPERVISION during cryotherapy sessions by trained...

 Open the catalog to page 4
Iceberg Cryonick Roller-5

Read instructions before use! Note: Describes how fitness roll shape functions or provides a note on how best to use it. Caution: Refers to the safe operation of device and provides cautions where the possibility of loss of data or damage to the equipment exists. Warning: Indicates a situation in which the operator or the patient may be in danger of injury or death Notes on package: Fragile, handle with care, Keep dry, This side Up, Keep away from sunlight, Transportation Humidity limitation, Transportation Atmospheric pressure limitation, Transportation Temperature Limitation Notes on machines:...

 Open the catalog to page 5
Iceberg Cryonick Roller-6

surfaces of machine should carry over virus and bacterias to other customers Caution: Use only cables and accessories approved by manufacturer authorized representative. Other cables and accessories may damage the system or interfere with the measurements. Do not charge software settings or upload third-party software updates. Caution: Do not store or transport the device system beyond the specified temperature ranges -40 to 70°C (-40 to 158°F) Caution: Do not use the RollStar system beyond the specified temperature range: 10 to 30°C (50 to 86°F Caution: Do not use the device system beyond the...

 Open the catalog to page 6
Iceberg Cryonick Roller-7

Technical specifications Voltage Power consumption 230VAC / 50Hz / 1PH 0.2kW European version Voltage Power consumption 120VAC / 60Hz / 1PH 0.4kW American version Drum drive ■ Engine control: Frequency inverter ■ Protection against scalding ■ Wireless remote control WiFi required Iceberg Cryonick Roller combined device is a product for influencing human skin and adipose tissues with the help of low and high temperatures, as well as mechanically by breaking adipose tissues with a roller. This device based on technology of heater exchange handle which creating hot and cold temperature on handle...

 Open the catalog to page 7
Iceberg Cryonick Roller-8

pain relief and reduce inflammationbenefits. Thermal therapy relaxes facial and body muscles. Also hot cold thermal shocktherapy expands and narrows blood vessels and capillaries. This is greatly improve theskin permeability and consequential product absorption ability. Hot therapy takes effect on fat tissue softening and burning fat. Lymphatic drainage massage is a form of gentle massage that encourages the movement of lymph fluids around the body. The fluid in the lymphatic system helps remove waste and toxins from body tissues. Some health conditions can cause lymph fluid to build up. Lymphatic...

 Open the catalog to page 8
Iceberg Cryonick Roller-10

Touchscreen display Liquid - antifreeze (based on ethylene glycol) heat exchanger Liquid - antifreeze (based on ethylene glycol) Material - copper Dimensions - 60x6 mm Temperature range -20 … +50оС Material - ceramics, bimetallic base Temperature range -20 … +50оС Maximum temperature difference Т = 59оС Power P = 100W Voltage U = 12V Maximum voltage I = 10A Material - copper Size - 60x6.5mm Lymphatic drainage handle Т4 Power P = 500 W Voltage U = 12 V Maximum voltage I = Massage drum Material – steel, plastic Size - 62x100 mm Bearing - 8x16x3.5 - 2

 Open the catalog to page 10
Iceberg Cryonick Roller-12

2.3 Lymphatic drainage roll handle

 Open the catalog to page 12
Iceberg Cryonick Roller-13

3. DESCRIPTION OF OPERATION 3.1 Main unit The coolant from the reservoir R enters the suction of the pump P, after which it enters the heat exchanger T2 in the manipulative handle. After the manipulative handle, the coolant returns to the main unit and enters the air-cooled radiator T1 where it is blown by two coolers C. After the radiator T1, the coolant returns to the tank. The pump performs a circulating role, as a result of which the operating mode of the tank R is under filling. The reservoir R is made of transparent plexiglass for visual control of the hydraulics. The system is connected...

 Open the catalog to page 13
Iceberg Cryonick Roller-14

4. Dimensions of device 4.1 Iceberg Cryonic Roller Mini 4.2 Iceberg Cryonick Roller

 Open the catalog to page 14
Iceberg Cryonick Roller-15

For initial start-up, you need: ■ check the device for completeness; ■ check the integrity of cables, power plugs, housing sockets; check the integrity of PVC pipes, the reliability of their attachment to fittings and fittings, inspect for deformations, kinks, cracks or breaks; ■ check the condition of the electrical equipment inside the main unit: ■ check the status of the pump, for which: ■ check the integrity of the case, the reliability of fastening to the frame, the elimination of backlash; ■ check the reliability of fixation of PVC pipes; ■ check the condition and connections of the wires;...

 Open the catalog to page 15

All Cryonick (Cryonick Wellness Technology Factory; Vacuactivus/Medstarcom) catalogs and technical brochures

  1. Iceberg

    16  Pages

  2. Price EUR 2026

    40  Pages

  3. VACUACTIVUS

    13  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.