1. Catalogs
  2. CSM Implant Company
  3. Submerged Ⅳ System
video corpo

Submerged Ⅳ System

Submerged Ⅳ System
1 / 30 PagesView full catalog

Submerged Ⅳ System

Product catalog summary
Overview: The document provides comprehensive details on the CSM Implant Submerged System, focusing on implants and abutments used in dental procedures. It includes technical specifications, product codes, and procedural guidelines.
Fixture Specifications: The document describes various fixture types such as Submerged IV, III, II, and standard Submerged Implants, detailing dimensions, hexagon types, and surface treatments to enhance osseointegration and reduce bone loss.
Abutment Types: It outlines different abutments including Healing, Octa, Temporary, Cementation, Angled, and Milling Abutments, with specific product codes and dimensions for compatibility with various fixture sizes.
Impression Coping: The use of Impression Coping for pick-up and transfer methods is explained, with specifications for hex and non-hex types, including product codes and collar dimensions.
Surface Treatment and Design: Implants feature dual laser surface treatment and a triple cutting edge for stability and early loading capability. The V-line apex design is emphasized for initial implantation success.
Procedural Guidelines: Instructions include handling and implanting fixtures, using mountless drivers, and torque specifications for screws.
Flowcharts and Diagrams: Flowcharts aid in visualizing the assembly and application of components.
Critical Information:
  • Surface Roughness: Implants have a roughness value (Ra) of 1.2um~1.8um for optimal osseointegration.
  • Connection Types: Specifies connection forms and dimensions like 2.1mm Double Hexagon and 2.5mm Hexagon for compatibility and stability.
  • Product Codes: Unique codes for each component facilitate accurate identification and ordering.
  • Torque Specifications: Specific torque values ensure proper fixation and stability.
Product Description: The CSM Submerged Implant System consists of titanium fixtures for jawbone insertion, providing a stable foundation for dental restorations.
Precautions: Implant placement requires specialized training and pre-operative screening, including radiographic evaluations.
Directions for Use: Surgical procedures must be aseptic with sterile instruments. A precise drilling sequence is recommended, and fixtures should be inserted 0.2mm below bone level. Healing periods vary between 45-90 days for the lower jaw and 90-180 days for the upper jaw.
Usage and Storage: The product is disposable and should not be reused. Store in low humidity and room temperature.
Caution: Potential complications include swelling, numbness, and infection. Contraindications include insufficient bone quality and certain medical conditions. Proper training and technique are crucial to avoid fixture failure.
Warnings: Fixtures should not be altered or used with electro-surgical instruments. Special considerations are necessary for certain patient groups, such as the elderly or pregnant women.
Package Management: Fixtures are sterilized with gamma radiation. Damaged or expired packages should not be used. Tools must be cleaned and sterilized post-operation, with specific handling and storage instructions.
See more

Catalog excerpts

Submerged Ⅳ System-1

CSM Implant 47, Gyeongdae-ro17-gil, Buk-gu, Daegu, Korea (Bokhyeon-dong, B205, B201 Techno B/D, Kyung-Pook National Univ.) Tel : +82-53-952-8261 Fax : +82-53-958-8261 SlVC-Rev01_AH/07

 Open the catalog to page 1
Submerged Ⅳ System-2

Submerged Implant Apolonid ' ~ Ci/cfom SIMCF mCM

 Open the catalog to page 2
Submerged Ⅳ System-4

Fixture Features Screw Connection The M.1.6 screw is coupled with 2.1 double hexagon xtures. And the other size of xtures are coupled with M2.0 Active RBM Surface Treatment Roughness value(Ra) of 1.2um~1.8um. The surface has optimized roughness value for osseointegration. Dual Laser Surface Treatment We are the world’s rst laser surface treatment technology holder for early loading. 11° Taper With perfect combination between abutment and 11° taper bacterial penetrations are prevented. Also it supports distribution of bone stress to minimize bone loss. Cutting Edge Triple cutting edge helps smooth...

 Open the catalog to page 4
Submerged Ⅳ System-5

Connection & Select Guide Connection Form Double Hexagon

 Open the catalog to page 5
Submerged Ⅳ System-6

Package System Check the size of xture and pull out the product from the box. Pull out mountless driver carefully after it rmly combined with xture by moving mountless driver right and left direction in the xture. Rip off the paper on plastic case and pull out the ampoule. Implantation. (Use CSM mountless driver softly in right and left way till it rmly combined with xture) Hold plastic ampoule and rotate the cap to open. Check inside of xture. Hold up the ampoule cap and remove cap cover. Use CSM torx driver and connect the screw and tighten coupling of the cover screw into the xture.

 Open the catalog to page 6
Submerged Ⅳ System-7

Impression Coping (Pick-up) Impression Coping (Transfer) Fixture Analogue Temporary Abutment Cementation Abutment Angled Abutment Milling Abutment UCLA Abutment Octa Abutment Impression Coping (Pick-up) Octa Abutment Analogue Temporary Cylinder Cementation Cylinder Cr-Co UCLA Cylinder Retainer Abutment Impression Plastic Male Impression Spacer Retainer Retention Male Cr-Co UCLA Abutment

 Open the catalog to page 7
Submerged Ⅳ System-8

Diameter (Ø) Length (mm) Pro’ Code Diameter (Ø) Length(mm) Pro’ Code L Diameter (Ø) Length (mm) Pro’ Code Diameter (Ø) Length (mm) Pro’ Code Diameter (Ø) Length (mm) Pro’ Code

 Open the catalog to page 8
Submerged Ⅳ System-9

6 CSM Implant Submerged III System

 Open the catalog to page 9
Submerged Ⅳ System-10

Temporary Abutment Cementation Abutment Angled Abutment Milling Abutment UCLA Abutment Fixture Analogue SYSTEM Impression Coping (Pick-up) Impression Coping (Transfer) Cr-Co UCLA Abutment

 Open the catalog to page 10
Submerged Ⅳ System-11

CSM Implant Submerged ■ System Impression Coping [Pick-up] Non-Hex dBB 4.0

 Open the catalog to page 11
Submerged Ⅳ System-12

CSM Implant Submerged ■ System Impression Coping [Transfer] Non-Hex Diameter (0) 4.5 4.5

 Open the catalog to page 12
Submerged Ⅳ System-13

Diameter (Ø) Length(mm) Pro’ Code Diameter (Ø) Length (mm) Pro’ Code

 Open the catalog to page 13
Submerged Ⅳ System-14

Temporary Abutment [Non-Hex] Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø ) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code

 Open the catalog to page 14
Submerged Ⅳ System-15

Cementation Abutment [Non-Hex] Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code

 Open the catalog to page 15
Submerged Ⅳ System-16

Milling Abutment [Non-Hex] Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code H Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code

 Open the catalog to page 16
Submerged Ⅳ System-17

15° Angled Abutment [Non-Hex] Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code

 Open the catalog to page 17
Submerged Ⅳ System-18

20° Angled Abutment [Non-Hex] Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code

 Open the catalog to page 18
Submerged Ⅳ System-19

6 CSM Implant Submerged III System

 Open the catalog to page 19
Submerged Ⅳ System-20

UCLA Abutment Cr-Co UCLA Abutment D Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code

 Open the catalog to page 20
Submerged Ⅳ System-21

Flowchart Temporary Cementation Cr-Co UCLA Cylinder Cylinder Cylinder

 Open the catalog to page 21
Submerged Ⅳ System-22

Octa Abutment 15° Octa Angeld Abutment Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code Diameter (Ø) Collar (mm) Pro’ Code

 Open the catalog to page 22
Submerged Ⅳ System-23

Octa Abutment Temporary Cylinder Octa Abutment System * Protector Cap Diameter (Ø) Height (mm) Pro’ Code Diameter (Ø) Height (mm) Pro’ Code *Screw COAS *Screw COAS * Impression Coping Diameter (Ø) Height (mm) Pro’ Code Diameter (Ø) Height (mm) Pro’ Code Diameter (Ø) Length (mm) Pro’ Code Diameter (Ø) Height (mm) Pro’ Code

 Open the catalog to page 23
Submerged Ⅳ System-24

Octa Abutment Cr-Co UCLA Cylinder Octa Abutment Cementation Cylinder Diameter (Ø) Height (mm) Pro’ Code Diameter (Ø) Height (mm) Pro’ Code *Screw COAS Diameter (Ø) Height (mm) Pro’ Code Diameter (Ø) Height (mm) Pro’ Code *Screw COAS

 Open the catalog to page 24
Submerged Ⅳ System-25

Flowchart Retainer Retainer Retention Male Impression Impression Plastic Male Spacer S UBMERGED Ill Overdenture Retainer Abutment

 Open the catalog to page 25
Submerged Ⅳ System-26

Retainer Abutment Retainer Abutment System * Retainer Cap D Diameter (Ø) Collar (mm) Pro’ Code * Retainer Retention Male C Diameter (Ø) Collar (mm) Pro’ Code * Retainer Impression Plastic Male Diameter (Ø) Collar (mm) Pro’ Code * Retainer Impression Spacer * Retainer Magic Tool

 Open the catalog to page 26

All CSM Implant Company catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.