Osiris

Osiris

Osiris

Product catalog summary
Overview: The Osiris Aberrometer is a comprehensive ocular measurement device that utilizes the Phoenix software platform for storing and analyzing patient data. It is designed to measure both high-order and standard refractive aberrations, providing critical evaluations for patients with complex ocular conditions.
Key Features:
  • High-Resolution Measurement: Capable of measuring aberrations with a resolution of 45,000 points at maximum pupil diameter, using a pyramidal sensor for real-time wavefront analysis at up to 33 frames per second.
  • Analysis Software: Integrates with Phoenix software to offer refractive error maps and visual simulations, aiding clinicians in understanding and explaining visual problems. It can combine data with topographic maps from other CSO instruments for comprehensive analysis.
  • Toric Lens Assistant: Helps evaluate toric lens performance by distinguishing astigmatic residue causes, whether due to lens rotation or calculation errors.
  • Dynamic Accommodation: Provides real-time wavefront measurement during accommodative phases with customizable exam modes.
  • Densitometry: Acquires backlit images for objective cataract and optical media opacity evaluation.
Technical Specifications:
  • Data Transfer: USB 3.0
  • Power Supply: External 24 VCC, with specific input and output requirements.
  • Dimensions and Weight: 425 x 315 x 265 mm, 5.8 kg
  • Chin Rest and Base Movement: Chin rest movement of 70mm ± 1mm, base movement of 105 x 110 x 30mm.
  • Working Distance: 78mm
  • Light Sources: Aberrometer LED at 850nm, Auxiliary LED at 780nm, Fixation LED at 450-650nm.
  • Aberrometry: Measures up to 45,000 points, spatial resolution of 41μm, pupil size range of 2-9mm, dioptric range from -25D to +15D, and repeatability of 0.05D.
  • Compatibility: Compatible with standard DICOM v3 and IHE integration profile EYECARE Workflow.
  • System Requirements: Minimum PC requirements include 4 GB RAM, 1 GB RAM video card, USB 3.0, and Windows XP, 7, or 10.
Contact Information: CSO, Via degli Stagnacci 12/E, 50018 Scandicci, FI, Italy. Phone: +39 055 72219, Fax: +39 055 7215557, Email: [email protected], Website: www.csoitalia.it
See more

Catalog excerpts

Osiris-1

ABERROMETER OSIRIS The ability to measure high order aberrations as well as standard refraction has become the new standard of care for your patients. Osiris, is a total ocular aberrometer, and is indispensable for the correct evaluation of critical patients who have, in addition to traditional low-order defects, even more complex ocular aberrations. Osiris has a unique design that enables it to measure aberrations with a resolution of 45,000 points (at the maximum pupil diameter), with a wide dynamic. Thanks to the use of a pyramidal sensor, Osiris is also able to measure the total wave-front in real time with a frame rate of up to 33 images per second: this makes it possible to measure and view changes in power and aberrations while the patient is accomodating. ANALYSIS SOFTWARE FOR ABERRATIONS The tool integrates with the Phoenix software, offering a wide range of analysis options, such as refractive error maps and visual simulations (PSF, MTF and convolution with optotype), which helps the clinician to understand and explain the patient’s visual problems. Osiris data can be combined with the topographic maps from other instruments produced by CSO, combining the total aberrometry with the corneal ones of Antares, Sirius or MS-39 it is possible to calculate the wavefront internal component and, for example, to evaluate the impact of a toric system on vision. DYNAMIC ACCOMODATION Real-time measurement of the ocular wavefront is indispensable during the evaluation of the accommodative phases. Customizable exam modes (ramps or square waves) are available to evaluate the patient’s ability to focus at near. For an objective assessment of cataract and optical media opacity evaluation, Osiris can acquire backlit images without reflections. TORIC LENS ASSISTANT For the evaluation of the performances of a toric system, the combination of corneal topography imported from CSO topographers and ocular aberration, makes it possible to distinguish whether any astigmatic residue is due to a rotation of the lens or to an incorrect calculation. FEATURES OF THE PHOENIX SOFTWARE Osiris uses the Phoenix software platform allowing patient data to be saved for future review and analysis, shared by all CSO dev

 Open the catalog to page 1
Osiris-2

TECHNICAL DATA Data transfer Power supply external power source 24 VCC In: 100-240Vac - 50/60Hz - 0.9-05A - Out: 24Vdc - 40W Dimensions (HxDxW) Chin rest movement Minimum height of the chin cup from table: Working distance LIGHT SOURCES Aberrometer ABERROMETRY Points measured at maximum pupil Spatial resolution Pupil size range Dioptric range Compatibility with standard DICOM v3 (IHE integration profile EYECARE Workflow) YOUR PROFESSIONAL PARTNER SINCE 1967 MINIMUM SYSTEM REQUIREMENT PC: 4 GB RAM - Video Card 1 GB RAM (not shared) resolution 1024 x 768 pixels - USB 3.0 type A Operating system:...

 Open the catalog to page 2

All CSO - Costruzione Strumenti Oftalmici catalogs and technical brochures

  1. VISION CHART

    3  Pages

  2. Vintage

    9  Pages

  3. ETOILE2

    2  Pages

  4. PERSEUS

    3  Pages

  5. Osiris-T

    2  Pages

  6. ANTARES

    6  Pages

  7. SIRIUS

    6  Pages

  8. MODI’ 02

    2  Pages

  9. MS-39

    6  Pages

  10. Cobra HD

    5  Pages

  11. RETIMAX

    6  Pages

  12. catalog 2011

    9  Pages

  13. CASSETTIERE

    2  Pages

  14. POLTRONE

    2  Pages

  15. Compact

    2  Pages

  16. ELEGANCE

    2  Pages

  17. FUTURE DELUXE

    2  Pages

  18. SP02

    2  Pages

  19. SERIE ELITE

    2  Pages

  20. MODELLI SL980

    2  Pages

  21. MODELLI SL990

    2  Pages

Archived catalogs

  1. Cobra

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.