SYSTEM Ingenious sample handling ITEX Dynamic Headspace Powerful Sample Enrichment for GC

Open the catalog to page 1
ITEX Dynamic Headspace - 2

ITEX (In-tube extraction) Dynamic Headspace Tool Purge & Trap (P&T) sensitivity without the pitfalls of P&T Systems – Rapid and efficient enrichment of volatile and semi-volatile compounds from solid, liquid and gaseous samples – In-tube extraction and thermal desorption using industry standard adsorbents – Syringe-only concept: no sample loops, transfer lines, or switching valves that could be contaminated – Active cooling allows for rapid sample preparation and short cycle times – No modifications of the GC injector needed – PAL Robotic Tool Change enables head space, SPME and...

Open the catalog to page 2
ITEX Dynamic Headspace - 3

The sample is heated and / or agitated in a sealed vial. The ITEX needle pierces the sealed vial and the heated syringe pumps the the headspace gas through the cold trap. The loaded ITEX trap is flash heated up to 350°C and analytes are desorbed into the hot GC injector. After thermal desorption the hot ITEX trap is cleaned with inert flush gas. Active cooling allows for short cycle times. An additional step to remove water from the trap can be added. nJrl Desorption Trap cleaning Active cooling

Open the catalog to page 3
ITEX Dynamic Headspace - 4

Powerful options for ITEX Dynamic Headspace The PAL RTC (Robotic Tool Change) takes productivity to new levels

Open the catalog to page 4
ITEX Dynamic Headspace - 5

Robotic Tool Change and ITEX Dynamic Headspace, ingeniously productive. – Headspace, SPME and ITEX sampling within the same sequence – Automatic selection of the syringe with optimal accuracy, e.g. for adding standards or preparing serial dilutions – Automated optimization of methods e.g. by selecting the most suitable ITEX trap and conditions – Derivatization reactions performed without manual intervention for productivity, process safety and protection against hazardous chemicals – Possibility to permanently configure several workflows on one system for a walk-up prep station, e.g....

Open the catalog to page 5
ITEX Dynamic Headspace - 6

Environmental application VOCs, BTEX in water at ppt levels, EPA 502.2 VOCs, full scan mode, 2 µg/L Retention time Sample preparation: Chromatography (Shimadzu GC-2010 Plus): Full scan data: 2 µg/L MegaMix® Standard, 524.2 73 components), Restek PN 30601 Temperature program: Restek catalog # 23321.1, 3.5 mm Splitless Single Tpr Gsnk SIM scan data: 10 ng/L MegaMix® Standard, 502.2 (54 components), Restek PN 30432 10mL water + standard, filled into 20 mL headspace vial, + 3g NaCl ITEX Dynamic Headspace conditions Incubation temp. Incubation time Syringe temp. Extraction strokes Extraction...

Open the catalog to page 6
ITEX Dynamic Headspace - 7

3 gr sample, 30 minutes equilibration time, 40°C Porapak Filter Technique 5 gr sample, 20 hours equilibration time, 25°C Limonene Eucalyptol Methylhexylketone cis-3-Hexenylacetate Rose oxide Cyclal C Tetrahydrolinalool Tetrahydromyrcenol Linalool Verdox Vertenex Citronellylacetate Pelargol Undecavertol Gardenol Benzylacetate DMBC acetate Allylcyclohexylpropionate Phenylethylacetate alpha-Methylionone Verdylacetate n-Methyl-alpha-Ionone Verdylpropionate Diphenyloxide Lilial Iso E super alpha-Hexylcinnamic aldehyde Chromatography (Thermo TraceGC): Column: Stabilwax 30 m x 0.25 mmID x 0.25 mm...

Open the catalog to page 7
ITEX Dynamic Headspace - 8

Full Scan Chromatogram (m/z 49-180) at l|zg/ l. Target compounds: 3) methyl tert-butyl ether, 4) ethyl tert-butyl ether, 7) tert-amyl methyl ether, GC Thermo Trace GC Ultra 40°C for 1 min., 4°C/ min. to 130°C, 10°C/ min. to 200°C for 10 min. MS Thermo DSQII El 70ev, Scan mode m/z 49-180 Injector AtasGL Optic 3 with cryfocusing unit 280°C Cryotrap - 165°C for 30 sec., 30°C/ sec. to 250°C GC Column Restek VMS 60 m x ,0.32 mm i.d., 1.8 pm film 1.5 mL/ min. constant flow Autosampler PAL RTC with ITEX Dynamic Headspace, 10 ml sample in 20 ml headspace vial Tenax GR/Carbosieve S3 trap Sample...

Open the catalog to page 8
ITEX Dynamic Headspace - 9

MDL: Method detection limit Ref: Laaks J, Jochmann MA, Schilling B, Schmidt TC ; Anal. Chem. 2010, 82, 7641-7648 Further application examples Environmental In-Tube Extraction of Volatile Organic Compounds from Aqueous Samples: An Economical Alternative to Purge and Trap Enrichment Jens Laaks,t Maik A. Jochmann,*,t Beat Schilling, and Torsten C. Schmidtt Anal. Chem. 2010, 82, 7641-7648 Clinical Headspace In-Tube Extraction Gas Chromatography-Mass Spectrometry for the Analysis of Hydroxylic Methyl-Derivatized and Volatile Organic Compounds in Blood and Urine Ilpo Rasanen, Jenni Viinamaki,...

Open the catalog to page 9
ITEX Dynamic Headspace - 10

PAL System Tools and Modules complementing ITEX Dynamic Headspace

Open the catalog to page 10
ITEX Dynamic Headspace - 11

ITEX Dynamic Headspace Specifications Trap temperature range Syringe temperature range Extraction flow rates Extraction stroke cycles (strokes/sample) Extraction volume Incubation time Standard adsorption material Tenax TA 80/100 mesh, other materials upon request Water removal step with adjustable trap temperatures Ventilated trap for quick sample processing Fast cooling of trap < 2 minutes PAL System Modules and Tools Agitator Module – – – – Incubation and agitation of 6 samples Incubation temperatures 40-200°C Agitation speed 250-750 rpm For 2 mL, 10 mL, 20 mL vials Vortex Mixer Module –...

Open the catalog to page 11
ITEX Dynamic Headspace - 12

For more information on the new generation PAL Systems visit: PAL is a registered trademark of CTC Analytics AG, Switzerland Part No. PAL Broch-ITEX - 2015 | Rev 1- February 2015